“It is a restricted book (lite) and restricted calculator exam, which means you are allowed one double-sided A4 sheet of paper with anything you like written/printed on it.” (ELECTENG 101 Examination page, Semester Two 2026 (Canvas))
1 · Universal Solve Loop Ch 1 · guide strategy
| Step | Write before arithmetic | Check |
|---|---|---|
| 1 Label | nodes, current arrows, voltage polarities | same reference throughout |
| 2 Constrain | component law + topology law | units; open I=0, short V=0 |
| 3 Solve | signed equations | substitute into originals |
| 4 Interpret | magnitude, unit, physical direction | Σp=0; boundary sense |
p = vi: p>0 absorbed; p<0 supplied
KCL: Σi at node = 0 · KVL: Σv around loop = 0
Which conservation law bites?
| Clue | Write | Do not assume |
|---|---|---|
| currents meet at one node | KCL with one entering/leaving convention | each branch current is positive |
| closed path with labelled polarities | KVL in traversal order | a “source” is automatically a rise |
| resistor current enters its + terminal | v=Ri and p=vi | negative result means failure |
| complete network power | sum signed element powers | magnitudes should be added |
2 · Choose the DC Method Ch 2 topic map + FAQ
| Method | Use when | Procedure / boundary |
|---|---|---|
| Series/parallel | true shared current / true shared voltage | redraw nodes first; branching breaks series |
| Node voltage | few essential nodes, many parallel branches | choose reference; each branch (Vₐ−Vᵦ)/R; one KCL per unknown node |
| Superposition | linear network, several independent sources | one source at a time; V-source→short, I-source→open; dependent sources stay; add signed V/I, never power |
| Thevenin | same network, changing external load | remove named load; Vth=Voc; find Rth looking in; preserve terminal polarity |
Divider across R₂: V₂ = VsR₂/(R₁+R₂)
Thevenin load: I = Vth/(Rth+RL); VL = IRL
Node-voltage pattern
Diagonal collects attached conductances; other unknown-node terms enter with opposite sign. A source between two unknown nodes creates a supernode.
Thevenin resistance
Deactivate independent sources only. If dependent sources remain or inspection fails, apply a test source at the named terminals and use Rth=Vtest/Itest. Endpoint checks: open circuit I=0 gives V=Vth; short circuit V=0 gives Isc=Vth/Rth.
Superposition ledger
- Fix one reference direction for the requested response.
- Keep one independent source active; set the others to zero using the correct open/short replacement.
- Redraw topology after each replacement; retained resistors remain connected.
- Calculate the signed contribution and repeat.
3 · Sensors → Voltage Ch 3 topic map + FAQ
Separate the chain: measurand → sensor resistance → interface voltage → receiver. Predict the direction before calculating; it catches a swapped divider leg or output polarity.
Lower-leg Rs ↑ ⇒ Vout ↑. Upper-leg Rs ↑ ⇒ Vout ↓.
Sensitivity near an operating point = ΔVout/Δ(measurand).
Finite receiver = loading
R₁∥R₂ = R₁R₂/(R₁+R₂)
Then reapply divider; compare with open-circuit Vout.
| Interface | What it preserves / reveals | Check |
|---|---|---|
| Single divider | large baseline plus sensor change | position controls output trend |
| Bridge | difference of two midpoint voltages; small imbalance about a null | declare right−left or left−right |
| Buffer | divider voltage while supplying next stage | very high input R; low output R; gain ≈1 |
Vout = declared midpoint subtraction. At balance: R₁R₄=R₂R₃.
Interface audit
| Stage | Input → output | Unit / boundary |
|---|---|---|
| sensor law | temperature, strain or light → resistance | physical units → Ω |
| divider/bridge | resistance → voltage | 0…Vs; declared polarity |
4 · Loading + Op-Amps Ch 4 topic map + FAQ
Buffer when the following stage materially changes the source voltage.
Ideal op-amp rules—conditional
| Rule | Use only when | Failure clue |
|---|---|---|
| i+ = i− = 0 | ideal input model | loading belongs in external network |
| v+ ≈ v− | negative feedback and unsaturated output | open-loop/comparator or clipped output |
| Follower Vout≈Vin | negative feedback; within input/output limits | benefit is isolation, not gain |
Non-inverting: Vout = (1+Rf/Rg)Vin
Inverting sum: Vout = −RfΣ(Vk/Rk)
Affine range design
For Vout=aVin+b, solve the two endpoint requirements first:
b=Vout,1−aVin,1
Diagnosis order
- Loaded input: did the receiver alter Vin?
- Feedback sign: does output correction reduce the input difference?
- Rails: is requested Vout physically reachable?
- Endpoint test: minimum, midpoint and maximum input.
KCL before memorised gain
At a virtual summing node, write each resistor current from labelled endpoints and use zero ideal input current. A “virtual ground” is feedback-held near ground, not a wire that can source or sink arbitrary current.
5 · Number Systems Ch 5 topic map + FAQ
n bits ⇒ 2ⁿ patterns; unsigned range 0…2ⁿ−1.
Minimum width: smallest integer n with 2ⁿ ≥ required states.
| Task | Method | Check |
|---|---|---|
| Base b → decimal | expand weighted powers | digits must be <b |
| Decimal → base b | repeated division; read remainders last-to-first | re-expand |
| Binary ↔ hex | group from right in 4 bits; pad left only | leading zeros keep width, not value |
| Size field | test neighbouring powers of two | smaller fails; chosen width suffices |
6 · Boolean Logic Ch 6 topic map + FAQ
| A | B | AND AB | OR A + B | XOR A⊕B |
|---|---|---|---|---|
| 0 | 0 | 0 | 0 | 0 |
| 0 | 1 | 0 | 1 | 1 |
| 1 | 0 | 0 | 1 | 1 |
| 1 | 1 | 1 | 1 | 0 |
A + AB=A; A(A + B)=A
¬(AB)=¬A + ¬B · ¬(A + B)=¬A¬B
From requirement to gates
- Define what 0 and 1 mean; mark active-low signals explicitly.
- Enumerate all input rows.
- For each output-1 row write its minterm: 1→variable, 0→complement.
- OR the minterms; simplify one named identity at a time.
- Rebuild the full truth table, especially adjacent boundary rows.
Guide safety-rule drill
7 · ADC Method Ch 7 topic map + FAQ
Keep three decisions separate: sampling chooses times, quantisation chooses amplitude zones, and encoding assigns fixed-width binary codes.
For stated floor rule: k=floor((Vin−Vmin)/Δ), clipped to 0…2ⁿ−1.
Encode k in exactly n bits.
| Specification change | Improves | Does not fix |
|---|---|---|
| add one bit | twice the codes; half nominal Δ for fixed range | missed time variation |
| raise sampling rate | time resolution | amplitude step size |
| change reference range | range/headroom trade-off | code count |
| gain + offset | useful sensor span uses more codes | over-range tolerance unless headroom retained |
State the endpoint convention. Floor, nearest-level and centred-code maps differ at thresholds. Above/below range gives an endpoint code and loses the overdrive magnitude.
8 · DC Motor Response Ch 8 topic map + FAQ
ω = 2π(rpm)/60 · Pshaft = τshaftω
Pin = VI · η = Pshaft/Pin
| Change | Causal sequence |
|---|---|
| Start / stall | ω≈0 → Eᵦ≈0 → Iₐ≈V/Rₐ, often large |
| Load torque ↑ | speed initially ↓ → Eᵦ↓ → Iₐ↑ → developed torque ↑ → new operating point |
| Efficiency check | convert rpm; distinguish developed from shaft torque; output must not exceed input |