Cambridge International as & A Level Chemistry (9701) · EXAM PREP

Unit 4 · Analysis (AS & A Level)

- one exam, every section, every strategy
4 Sections13-page Guide
Our own words - no official Cambridge International as & A Level Chemistry (9701) materials
Built for the current Cambridge International as & A Level Chemistry (9701) format · kept up to date
The Complete Cambridge International AS & A Level Chemistry (9701) Guide · Cambridge International AS & A Level Chemistry (9701)

Unit 4 · Analysis (AS & A Level)

— Analysis
  • The Complete Cambridge International AS & A Level Chemistry (9701) Guide
  • Cambridge International AS & A Level Chemistry (9701)
  • 4 sections

Cambridge International does not publish a per-unit weighting for this exam. Exam structure (official): AS Level: Multiple Choice (75 min, 40 questions, 31%) · AS Level Structured Questions (75 min, 46%) · Advanced Practical Skills (120 min, 23%); A Level: Multiple Choice (75 min, 40 questions, 15.5%) · AS Level Structured Questions (75 min, 23%) · Advanced Practical Skills (120 min, 11.5%) · A Level Structured Questions (120 min, 38.5%) · Planning, Analysis And Evaluation (75 min, 11.5%). Be ready to carry the same unit skills and representations into a complete answer on every paper. Analysis begins by naming the signal: a peak, spot, absorbance, titre, or observation. Its scale and uncertainty determine which conclusion the evidence can support.

  • How Cambridge International AS & A Level Chemistry (9701) assesses this Cambridge International publishes no per-unit percentage for Cambridge International A Level Chemistry; Paper 1 accounts for 31% of the AS Level total and 15.5% of the A Level total. · AS Level: Multiple Choice (75 min, 40 questions, 31%) · AS Level Structured Questions (75 min, 46%) · Advanced Practical Skills (120 min, 23%) | A Level: Multiple Choice (75 min, 40 questions, 15.5%) · AS Level Structured Questions (75 min, 23%) · Advanced Practical Skills (120 min, 11.5%) · A Level Structured Questions (120 min, 38.5%) · Planning, Analysis And Evaluation (75 min, 11.5%) · show the model with a labeled mass or infrared spectrum, a calibration graph with equation, units, and supported range, a measurement table that retains repeats, spread, and anomalies, a combined spectral-assignment table, a calibration line with gradient, intercept, range, and units, a planned results table with repeats, uncertainty, and an evaluation criterion
  • Key skills Infrared Spectroscopy: Identifying Functional Groups, Mass Spectrometry: Isotopic Abundance, Relative Atomic Mass and Molecular Ion, [M+1] and [M+2] Peaks, Mass Spectrometry: Fragmentation and Identifying Molecules, Thin-Layer Chromatography and Gas/Liquid Chromatography (A Level), Carbon-13 NMR Spectroscopy (A Level), Proton NMR Spectroscopy (A Level)
  • How to study for Unit 4 This page turns a labeled mass or infrared spectrum, a calibration graph with equation, units, and supported range, a measurement table that retains repeats, spread, and anomalies, a combined spectral-assignment table, a calibration line with gradient, intercept, range, and units, a planned results table with repeats, uncertainty, and an evaluation criterion into one route: Name the measured signal, its unit, range, and uncertainty before proposing a structure or concentration..
  • The organizing decision Combine independent analytical signals only after each measurement has been translated into a bounded chemical constraint.
  • What A Level adds Use combined spectra, calibration, controls, repeats, and uncertainty to reach a conclusion no more precise than the evidence. Topics: Thin-Layer Chromatography and Gas/Liquid Chromatography; Carbon-13 NMR Spectroscopy; Proton NMR Spectroscopy.
Cambridge International AS & A Level Chemistry (9701) · Unit 4 of 4
Exam weight

Cambridge International does not publish a per-unit weighting for this exam.

Official unit name and weighting: Cambridge International syllabus.

Analysis

Connect the published share to the unit model

Analysis begins by naming the signal: a peak, spot, absorbance, titre, or observation. Its scale and uncertainty determine which conclusion the evidence can support.

No separate percentage is published for this domain. Five pages develop spectra, calibration, chromatography, and recording practice without implying an official priority order.

Use the 3×3 map to move from raw signal to chemical claim. Preserve units, calibration range, and relevant resolution at every step. Independent techniques strengthen a conclusion only when each observation is stated before the combined structural inference.

Treat every analytical result as a chain from measurement to constraint to conclusion. Begin with hard information such as formula, unsaturation, calibration range, or instrument resolution. Assign only diagnostic signals, then reconcile all environments, peak areas, splitting, masses, absorptions, or retention measurements with one structure or concentration. A proposed answer must account for every supplied datum; if two possibilities remain, state the unresolved ambiguity instead of forcing certainty. For graphical data, identify variables and units, use a scale that displays the observations clearly, retain spread and anomalies, and extract gradient, intercept, or trend from suitable points. End with a result whose precision and confidence do not exceed the evidence.

In a measurement table, separate each raw reading from the processed value and the final chemical claim. Record the instrument display with its unit and resolution, show the conversion applied, and only then state the result supported by the record. For titration data, preserve every trial, identify the concordant values, and explain any exclusion rather than erasing it. Keep the selected mean, conversion factors, amount ratio, final unit, and uncertainty visible through the calculation. This recording audit lets another student reproduce the numerical decision and exposes any unsupported precision.

The decision that organizes this unit

Define the system and choose the route before calculating

Combine independent analytical signals only after each measurement has been translated into a bounded chemical constraint.

First move

Name the measured signal, its unit, range, and uncertainty before proposing a structure or concentration.

Mechanism route and repair branches

Relationships to preserve

  • Mass spectra is shown through assign m/z and ion role.
  • Infrared is shown through bond and region stated.
  • Experimental data is shown through unit, spread, anomaly, conclusion.
  • Combined spectra is shown through assign every signal.
  • Calibration is shown through equation, unit, interpolation.
  • Planning is shown through variables, repeats, safety, criterion.

Representations to read

  • a labeled mass or infrared spectrum
  • a calibration graph with equation, units, and supported range
  • a measurement table that retains repeats, spread, and anomalies
  • a combined spectral-assignment table
  • a calibration line with gradient, intercept, range, and units
  • a planned results table with repeats, uncertainty, and an evaluation criterion

Branches to reject

  • using one peak as a complete structural identity
  • extrapolating beyond the supported calibration range
  • reporting more precision or certainty than the instrument and data support
  • forcing one structure before assigning every supplied signal
  • ignoring a non-zero calibration intercept
  • proposing an improvement without linking it to random variation or consistent bias
Key conceptWhy it's hardWhat scores
Mass spectraPosition and abundance differAssign m/z and ion role
InfraredAbsence can constrainBond and region stated
Experimental dataPrecision differs from accuracyUnit, spread, anomaly, conclusion
Assessment

How Cambridge International AS & A Level Chemistry (9701) assesses Analysis (AS & A Level)

What a complete response must make visible

Match the task to evidence that a reader can audit, then check the most likely reasoning failure before finalizing the response.

TaskEvidence to showHurdle
Infrared Spectroscopy: Identifying Functional Groupsmolecular ion; calibration curve; measurement uncertaintyusing one peak as a complete structural identity
Mass Spectrometry: Isotopic Abundance, Relative Atomic Mass and Molecular Ion, [M+1] and [M+2] Peaksmolecular ion; calibration curve; measurement uncertaintyextrapolating beyond the supported calibration range
Mass Spectrometry: Fragmentation and Identifying Moleculesmolecular ion; calibration curve; measurement uncertaintyreporting more precision or certainty than the instrument and data support
Thin-Layer Chromatography and Gas/Liquid Chromatography (A Level)proton NMR; non-zero intercept; percentage uncertaintyforcing one structure before assigning every supplied signal
Carbon-13 NMR Spectroscopy (A Level)proton NMR; non-zero intercept; percentage uncertaintyignoring a non-zero calibration intercept
Proton NMR Spectroscopy (A Level)proton NMR; non-zero intercept; percentage uncertaintyproposing an improvement without linking it to random variation or consistent bias
Worked examples

Combine mass and infrared evidence

Read each question as it appears on the exam paper, choose your answer, then tap it to see the feedback.

Practice 1: Combine mass and infrared evidence

Q. Which approach gives the structure with the evidence needed for all four marks? Read the exam question below, choose one option, then tap it to check.
9701/42 · Question 3A Level Structured Questions · 120 minutes

Compound X has the molecular formula C₃H₆O.

The mass spectrum of X has a molecular ion peak at m/z 58 and a strong fragment peak at m/z 43. Its infrared spectrum has an absorption near 1715 cm⁻¹ and no broad O–H absorption. Deduce the structure of X and explain how the evidence supports your answer.

[4]

Show all necessary working.

Account for every item of spectral evidence.

A. Identify propanone from the C=O absorption alone.

❌ Not quite 😭 The absorption supports a carbonyl group, but one peak does not establish the complete structure. This leaves the formula, molecular ion, missing O–H absorption and fragment unaccounted for.

Prep with Sia Agent

Free download for Mac and Windows. Choose your computer:

Mac (Apple silicon) · Mac (Intel) · Windows

B. Calculate one degree of unsaturation, assign C=O and the missing O–H, then check propanone against m/z 58 and 43.

✅ Correct! 😊 This builds independent constraints before naming the molecule. Propanone fits the formula and molecular ion, while CH₃CO⁺ explains the strong fragment at m/z 43.

C. Choose propan-1-ol because the formula contains one oxygen atom.

❌ Not quite 😭 An oxygen atom does not automatically mean an alcohol. Propan-1-ol has a different molecular formula, and the absent broad O–H absorption conflicts with that choice.

Prep with Sia Agent

Free download for Mac and Windows. Choose your computer:

Mac (Apple silicon) · Mac (Intel) · Windows

D. Assign m/z 43 as the molecular ion and propose an aldehyde without checking the other data.

❌ Not quite 😭 The molecular ion is stated to be m/z 58, so m/z 43 must be treated as a fragment. An unsupported aldehyde also fails to reconcile every supplied signal.

Prep with Sia Agent

Free download for Mac and Windows. Choose your computer:

Mac (Apple silicon) · Mac (Intel) · Windows

Full explanation
  • Step 1C₃H₆O has one degree of unsaturation, so a double bond or ring must be present.
  • Step 2The absorption near 1715 cm⁻¹ supports C=O; the missing broad O–H absorption argues against an alcohol.
  • Step 3Propanone, CH₃COCH₃, has the correct formula and relative molecular mass of 58.
  • Step 4Cleavage produces CH₃CO⁺ at m/z 43, so the proposed structure accounts for every observation.
Answer. B. Calculate one degree of unsaturation, assign C=O and the missing O–H, then check propanone against m/z 58 and 43.
Model solution. The structure is CH₃COCH₃ because formula, molecular ion, carbonyl absorption, missing O–H, and fragment are all assigned.
Mark scheme focus. Translate each spectrum feature into a chemical constraint, then accept a structure only when its formula, molecular ion, functional group and fragment all agree.

Practice 2: Use a calibration equation within its range

Q. Which calculation and conclusion correctly use the calibration line? Read the exam question below, choose one option, then tap it to check.
9701/42 · Question 6A Level Structured Questions · 120 minutes

A calibration line for solutions from 0.50 to 4.00 mmol dm⁻³ has the equation A = 0.160c + 0.020, where A is absorbance and c is concentration in mmol dm⁻³.

An unknown solution gives A = 0.420. Calculate its concentration and explain whether the calibration is being used by interpolation or extrapolation.

[4]

Show all necessary working.

Give your answer in mmol dm⁻³.

A. c = 0.420 ÷ 0.160 = 2.63 mmol dm⁻³; interpolation

❌ Not quite 😭 This divides by the gradient but ignores the non-zero intercept. Although 2.63 lies within the stated range, the concentration is not calculated from the complete equation.

Prep with Sia Agent

Free download for Mac and Windows. Choose your computer:

Mac (Apple silicon) · Mac (Intel) · Windows

B. c = (0.420 − 0.020) ÷ 0.160 = 2.50 mmol dm⁻³; interpolation

✅ Correct! 😊 This rearranges the full calibration equation and retains the intercept. The result lies between 0.50 and 4.00 mmol dm⁻³, so it is an interpolation.

C. c = (0.420 + 0.020) ÷ 0.160 = 2.75 mmol dm⁻³; extrapolation

❌ Not quite 😭 Adding the intercept reverses the required rearrangement. The claimed extrapolation is also wrong because the calculated value remains inside the supported concentration range.

Prep with Sia Agent

Free download for Mac and Windows. Choose your computer:

Mac (Apple silicon) · Mac (Intel) · Windows

D. c = 0.160 × 0.420 + 0.020 = 0.087 mmol dm⁻³; interpolation

❌ Not quite 😭 The equation predicts absorbance from concentration, so multiplying absorbance by the gradient does not invert it. The resulting value is outside the stated range and cannot be called interpolation.

Prep with Sia Agent

Free download for Mac and Windows. Choose your computer:

Mac (Apple silicon) · Mac (Intel) · Windows

Full explanation
  • Step 1Keep the response and concentration distinct: A is measured, while c is required.
  • Step 2Rearrange the complete line, including its intercept: c = (A − 0.020) ÷ 0.160.
  • Step 3Substitution gives c = (0.420 − 0.020) ÷ 0.160 = 2.50 mmol dm⁻³.
  • Step 4Because 2.50 mmol dm⁻³ lies within 0.50–4.00 mmol dm⁻³, the use is interpolation.
Answer. B. c = (0.420 − 0.020) ÷ 0.160 = 2.50 mmol dm⁻³; interpolation
Model solution. A = 0.160c + 0.020, so c = (A − 0.020) ÷ 0.160. For A = 0.420, c = (0.420 − 0.020) ÷ 0.160 = 2.50 mmol dm⁻³. This concentration lies within the calibrated range of 0.50 to 4.00 mmol dm⁻³, so the result is obtained by interpolation, not extrapolation.
Mark scheme focus. Use the complete calibration equation with correct units and state whether the result lies inside the supported calibration range.
Glossary

Key terms for Unit 4: Analysis (AS & A Level)

Models, uses, and boundaries

Data Map
Mean and range preserve center and spread. Use this data map when the question calls for the relationship described here.
Spectral Constraint
Formula and mass bound the candidates. Use this spectral constraint when the question calls for the relationship described here.
Calibration
Division by slope produces concentration. Use this calibration when the question calls for the relationship described here.
Alvc-U4-A01
The diagram labels lid, front, spot, origin, solvent, and measurement direction. Use this alvc-u4-a01 when the question calls for the relationship described here.
Repeats
The mean displays contributing measurements. Use this repeats when the question calls for the relationship described here.
Analysis Map
A defensible structure lies at intersecting evidence. Use this analysis map when the question calls for the relationship described here.
Structure
Formula and environments converge on propanoic acid. Use this structure when the question calls for the relationship described here.
Linear Fit
Rearrangement retains the measured intercept. Use this linear fit when the question calls for the relationship described here.
Alvc-U8-A01
The setup labels vessel, heater, probe, delivery path, syringe, and timer. Use this alvc-u8-a01 when the question calls for the relationship described here.
Uncertainty
The ratio shows why small readings carry larger percentages. Use this uncertainty when the question calls for the relationship described here.
FAQ

Cambridge International AS & A Level Chemistry (9701) Unit 4 FAQ

How much of Cambridge International AS & A Level Chemistry (9701) does Unit 4 carry?

Cambridge International does not publish a per-unit weighting for this exam.

What is the first move on a Analysis (AS & A Level) problem?

Name the measured signal, its unit, range, and uncertainty before proposing a structure or concentration.

Which relationships should I preserve?

Mass spectra is shown through assign m/z and ion role. Infrared is shown through bond and region stated. Experimental data is shown through unit, spread, anomaly, conclusion. Combined spectra is shown through assign every signal. Calibration is shown through equation, unit, interpolation. Planning is shown through variables, repeats, safety, criterion.

Which representations should I practice?

Practice moving among a labeled mass or infrared spectrum, a calibration graph with equation, units, and supported range, a measurement table that retains repeats, spread, and anomalies, a combined spectral-assignment table, a calibration line with gradient, intercept, range, and units, a planned results table with repeats, uncertainty, and an evaluation criterion.

What error should I check before submitting an answer?

Check for using one peak as a complete structural identity; extrapolating beyond the supported calibration range; reporting more precision or certainty than the instrument and data support; forcing one structure before assigning every supplied signal; ignoring a non-zero calibration intercept; proposing an improvement without linking it to random variation or consistent bias.

Evidence workshop

Continue from the free model into complete practice

The full unit guide continues with the chapter’s worked examples, figures, scoring tables, and answer checks.

  • Combine mass and infrared evidence
  • Interpolate a calibration with uncertainty
  • Measure a retention factor from one origin
  • Match precision to the instrument

Full unit practice. Open the complete guide for the full evidence workshop and synthesis.

Study strategy

How to study Cambridge International AS & A Level Chemistry (9701) Unit 4

Start with the organizing decision

Before solving, restate the decision in operational terms: Combine independent analytical signals only after each measurement has been translated into a bounded chemical constraint.. Your first written move should be to Name the measured signal, its unit, range, and uncertainty before proposing a structure or concentration..

Practice the same idea in several representations

Rotate through a labeled mass or infrared spectrum, a calibration graph with equation, units, and supported range, a measurement table that retains repeats, spread, and anomalies, a combined spectral-assignment table, a calibration line with gradient, intercept, range, and units, a planned results table with repeats, uncertainty, and an evaluation criterion. Use each representation to practice Infrared Spectroscopy: Identifying Functional Groups, Mass Spectrometry: Isotopic Abundance, Relative Atomic Mass and Molecular Ion, [M+1] and [M+2] Peaks, Mass Spectrometry: Fragmentation and Identifying Molecules, Thin-Layer Chromatography and Gas/Liquid Chromatography (A Level), Carbon-13 NMR Spectroscopy (A Level), Proton NMR Spectroscopy (A Level), and explain what stays invariant when the surface form changes.

Turn each error into a repair check

After every attempt, audit the response for using one peak as a complete structural identity; extrapolating beyond the supported calibration range; reporting more precision or certainty than the instrument and data support; forcing one structure before assigning every supplied signal; ignoring a non-zero calibration intercept; proposing an improvement without linking it to random variation or consistent bias. Then redo only the first step that made the reasoning diverge, keeping units, direction, and model conditions visible.

Confirm current course details in the official Cambridge International syllabus for the 2025-2027 administration.

Next

Where to go next

Return to the Cambridge International AS & A Level Chemistry (9701) to see every unit and plan your revision.

AskSia is not affiliated with or endorsed by Cambridge University Press & Assessment. Cambridge International is a trademark of Cambridge University Press & Assessment.
A+Everything unlocked
Unlocks this guide + all 4 Cambridge International as & A Level Chemistry (9701) sections - and more exam prep guides across AskSia.
Sia - your Cambridge International as & A Level Chemistry (9701) prep tutor, unlimited, worked the way the exam marks it
The full 13-page guide + practice bank with worked solutions
Chrome extension - bring Sia to any practice question on the web
Bilingual EN / Chinese on every guide and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works
Cambridge International as & A Level Chemistry (9701) · Analysis (AS & A Level) - independent study guide on the AskSia Library. More Cambridge International as & A Level Chemistry (9701) prep
Unlock the full Cambridge International as & A Level Chemistry (9701) guide + 4 Cambridge International as & A Level Chemistry (9701) sections
$0.99 Trial