The Chinese University of Hong Kong · FACULTY OF HEALTH & MEDICINE

BMEG5720 Chap.2 Cardiovascular and Respiratory Physiology

- one subject, every graph, every model, every mark
8 Chapters4-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 2 of 6 · BMEG5720

Cardiovascular and Respiratory Physiology

Pressure differences create expansion and flow

This chapter links lung mechanics, ventilation, diffusion, oxygen transport and circulation. Transpulmonary pressure keeps the elastic lung expanded, compliance describes its volume response, and airway resistance opposes flow.

Partial pressure drives diffusion, while oxygen content and cardiac output determine delivery to tissues.

Cellular calcium reaches organ-level pressure

Cardiac output and peripheral resistance organise blood pressure. Vascular smooth-muscle tone depends strongly on intracellular calcium, while pressure and shear provide mechanical signals to vessel walls and endothelium.

Each measurement belongs to a boundary, so interpretation begins by asking what crossed which boundary.

Do not collapse movement, exchange and delivery

Minute ventilation measures gas moved per minute. Diffusion describes transfer across the alveolar barrier. Oxygen content describes how much oxygen a litre of blood carries, mostly on haemoglobin. Cardiac output describes how many litres move each minute.

A disturbance can affect one stage while leaving another close to normal, which is why a single number rarely locates the limit.

Compliance and resistance also answer different mechanical questions. Low compliance means a given pressure change produces too little volume change. High resistance means flow is limited along the airway.

Destruction of lung tissue can raise compliance while worsening recoil and exchange, so easier expansion is not automatically better function. State the measured property before applying a clinical label.

Circulation repeats the product structure. Arterial pressure reflects both cardiac output and peripheral resistance, while oxygen delivery reflects cardiac output and blood oxygen content.

Recalculate the product whenever factors move in opposite directions. Then connect vascular tone to calcium-dependent smooth-muscle contraction and endothelial responses to shear, keeping force across the wall separate from tangential force along it.

In this chapter

What this chapter covers

  • 01

    Alveolar and intrapleural pressure

  • 02

    Transpulmonary pressure and lung recoil

  • 03

    Compliance against airway resistance

  • 04

    Minute ventilation

  • 05

    Partial pressure and diffusion

  • 06

    Haemoglobin-bound oxygen

  • 07

    Cardiac output and oxygen delivery

  • 08

    Peripheral resistance and vascular calcium

Worked example · free

Separate blood flow from oxygen content

Q [6 marks]. The marks used to pace this calculation are not a University marking scheme. Cardiac output changes from 5.0 to 6.5 L/min while oxygen content remains 188 mL/L. Calculate both delivery rates and interpret the change.
Ventilation supplies alveolar gas, diffusion transfers oxygen, haemoglobin determines most blood content, and cardiac output sets how much oxygenated blood reacVentilation supplies alveolar gas, diffusion transfers oxygen, haemoglobin determines most blood content, and cardiac output sets how much oxygenated blood reaches tissues each minute.Oxygen delivery joins gas exchange to blood flowVentilationDiffusionBlood contentCardiac outputdelivery = oxygen content × cardiac output
Ventilation supplies alveolar gas, diffusion transfers oxygen, haemoglobin determines most blood content, and cardiac output sets how much oxygenated blood reaches tissues each minute.
  • 2Calculate the initial delivery.
  • 2Calculate the later delivery and difference.
  • 2Identify which factor changed.
Initial delivery is 5.0 × 188 = 940 mL/min. Later delivery is 6.5 × 188 = 1,222 mL/min, an increase of 282 mL/min. Oxygen content per litre is unchanged, so the rise comes from increased blood flow rather than greater oxygen loading.
Sia tip — Keep litres beside cardiac output until multiplication shows exactly which unit cancels.
Glossary

Key terms

Transpulmonary Pressure
Alveolar pressure minus intrapleural pressure, providing the distending pressure across the lung.
Minute Ventilation
The volume of gas moved between atmosphere and lungs each minute.
Diffusion Capacity
A measure combining properties that determine gas transfer for a given pressure difference.
Peripheral Resistance
The opposition to blood flow produced mainly by small arteries and arterioles.
Shear Stress
Tangential frictional force applied by flowing blood to the vessel wall.
FAQ

Cardiovascular and Respiratory Physiology FAQ

Why can high lung compliance still be abnormal?

Compliance describes ease of expansion, not overall gas-exchange quality. Destruction of alveolar walls can make a lung easier to stretch while reducing recoil and exchange area. Interpretation must therefore pair compliance with airway behaviour, volumes and gas transfer rather than treating a high value as healthy. Always state the pressure difference across the structure and the associated volume change.

Then ask whether recoil, airway resistance, diffusion area or barrier thickness has changed independently. This separates a mechanical measurement from the later steps that determine alveolar exchange and oxygen delivery.

Does higher minute ventilation guarantee higher oxygen transfer?

No. Minute ventilation measures gas movement, while transfer also depends on effective alveolar ventilation, diffusion area and thickness, partial-pressure differences and matching with blood flow. Extra ventilation can reach poorly perfused regions or fail to overcome an impaired exchange barrier.

How can pressure fall when cardiac output rises?

Blood pressure depends on both cardiac output and peripheral resistance. If output rises modestly while resistance falls by a larger proportion, their product can decrease. Recompute both factors before assigning the direction, especially when vasodilation and reflex cardiac changes occur together.

Study strategy

Exam move

Keep a four-column sheet for pressure, flow, content and resistance. Recompute ventilation, partial pressure, oxygen delivery and indexed blood pressure with new values and units. Then explain one respiratory and one cardiovascular disturbance without a disease label: name the changed mechanical or transport property, follow it to the measurement, and identify one additional observation that would distinguish competing limits.

Build an integrated chain beginning with a pressure or concentration difference and ending with tissue delivery. Inspiration changes the distending pressure, alveolar ventilation refreshes gas, diffusion crosses a thin barrier, haemoglobin increases carrying capacity, and cardiac output transports the content. Test the chain by changing one variable at a time.

Raising ventilation does not replace missing haemoglobin, and adequate oxygen content cannot compensate indefinitely for inadequate flow. State the measured variable at every transition and avoid substituting partial pressure for content. Add units before calculating, keep pressure compartments explicit and distinguish resistance to flow from compliance of an elastic structure.

This routine locates whether the main limit lies in ventilation, exchange, circulation or final delivery.

A+Everything unlocked
Unlocks this Bible + all 13 of your subjects at The Chinese University of Hong Kong, plus 1,000+ more Bibles across the AskSia library.
Sia - your BMEG5720 tutor, unlimited, worked the way the exam marks it
The full 4-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works