The Chinese University of Hong Kong · FACULTY OF HEALTH & MEDICINE

BMEG5720 Chap.5 Ion Channels and Electrophysiology

- one subject, every graph, every model, every mark
8 Chapters5-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 5 of 6 · BMEG5720

Ion Channels and Electrophysiology

Channels use gradients that transporters maintain

Ion channels create selective aqueous pores and conduct ions rapidly down electrochemical gradients. Voltage, ligand or mechanical force can gate them.

Unequal ion concentrations and selective permeability create resting membrane voltage, while thresholded channel feedback generates regenerative action potentials.

Recording mode defines interpretation

Voltage clamp fixes voltage and measures current; current clamp injects current and records voltage. Patch configurations change membrane area, surface orientation, intracellular access and resolution.

The correct method follows the experimental question rather than a hierarchy of techniques.

Separate selectivity, gating and direction

Selectivity determines which ion fits the pore, gating determines when the pore opens, and the electrochemical gradient determines movement while it is open. Mixing those properties produces vague explanations.

A mutation may change opening probability without changing ion selectivity, while a concentration change can reverse current direction without changing the channel protein.

Action-potential threshold is a feedback transition. Below threshold, local voltage changes decay. Above threshold, voltage-sensitive inward current opens more channels and creates a regenerative event.

Inactivation leaves membrane behind the wave temporarily unavailable, while membrane ahead remains excitable. Frequency and recruitment then encode stimulus strength without enlarging each action potential.

Experimental reasoning begins with the boundary. Voltage clamp controls voltage; current clamp controls injected current.

Cell-attached recording preserves intracellular regulation, inside-out exposes the cytoplasmic surface, outside-out exposes the extracellular surface, and whole-cell access combines many channels while exchanging soluble contents. State what must remain intact before selecting the method, then connect the measured current to the physiological output.

In this chapter

What this chapter covers

  • 01

    Selective ion pores

  • 02

    Electrochemical gradients

  • 03

    Resting membrane potential

  • 04

    Voltage, ligand and mechanical gating

  • 05

    Action-potential threshold

  • 06

    Voltage clamp and current clamp

  • 07

    Patch configurations

  • 08

    Beta-cell insulin secretion

Worked example · free

Choose a clamp method

Q [6 marks]. The mark allocation here is not part of a published University assessment scheme. You need to measure current through channels while membrane voltage is stepped through selected values. Which clamp mode is required, and what does it measure?
Voltage clamp imposes membrane voltage and records the current needed to maintain it, whereas current clamp injects current and records the voltage a cell produVoltage clamp imposes membrane voltage and records the current needed to maintain it, whereas current clamp injects current and records the voltage a cell produces.The controlled variable determines the recording modeVoltage clampHold voltageMeasure currentCurrent clampInject currentMeasure voltageSwap what is imposed and what is allowed to respond.
Voltage clamp imposes membrane voltage and records the current needed to maintain it, whereas current clamp injects current and records the voltage a cell produces.
  • 2Identify the controlled variable.
  • 2Select the recording mode.
  • 2State the measured response.
Membrane voltage is the controlled independent variable, so voltage clamp is required. The amplifier supplies the current needed to hold each commanded voltage, and that recorded current reveals the voltage-dependent conductance and gating of the channels under study.
Sia tip — Say what is held and what is measured before naming the clamp.
Glossary

Key terms

Selective Permeability
Preferential passage of particular ions according to pore size, charge and channel structure.
Depolarisation
A membrane-voltage change that makes the cell interior less negative relative to the exterior.
Voltage Clamp
A method that imposes membrane voltage and records the current required to maintain it.
Current Clamp
A method that injects current while allowing membrane voltage to respond freely.
Gigaohm Seal
A high-resistance seal between patch pipette and membrane that limits leakage current.
FAQ

Ion Channels and Electrophysiology FAQ

Why are ion channels always passive transport routes?

Channels provide pores but do not couple ion movement to an energy source. Ions therefore move down their electrochemical gradients while a channel is open. Pumps and coupled transporters expend energy to establish the unequal concentrations that make channel current possible.

In an unfamiliar problem, name the ion, compare its concentration on both sides, include the electrical attraction or repulsion at the stated voltage and then predict current direction. Only after that should you infer depolarisation or hyperpolarisation. This order avoids assigning a fixed voltage effect to an ion regardless of its gradient.

How do voltage clamp and current clamp differ?

Voltage clamp holds membrane voltage at a command value and measures the current needed to do so, making it useful for channel conductance. Current clamp injects a chosen current and records the resulting voltage, making it useful for resting potentials and action potentials.

Why does closing a potassium channel stimulate insulin secretion?

In beta cells, glucose metabolism raises ATP and closes ATP-sensitive potassium channels. Reduced outward potassium current depolarises the membrane, opening voltage-sensitive calcium channels. Calcium entry then triggers insulin exocytosis, so channel closure links nutrient metabolism to secretion.

Study strategy

Exam move

For each ion-current problem, write the concentration gradient, electrical force, channel state and current direction. Draw an action potential with the refractory region behind the wave. Compare patch modes by membrane integrity, exposed surface and cellular access.

Finally, rehearse the beta-cell chain from glucose through ATP, potassium-channel closure, depolarisation, calcium entry and insulin release without skipping a step. Interpret experiments in the order imposed by the apparatus. Specify the command variable, measured response, ionic solutions and membrane face exposed to each solution.

A current change after a ligand is meaningful only if the voltage protocol and comparison condition are clear. Single-channel recordings reveal openings and conductance, whereas whole-cell recordings sum activity across many channels and can lose soluble intracellular regulators. Neither scale is automatically superior.

Choose the boundary that preserves the mechanism of interest, include a matched control, repeat the command waveform and relate the electrical observation to excitability, contraction or secretion rather than stopping at the trace. State what the method cannot preserve as well as what it measures.

A+Everything unlocked
Unlocks this Bible + all 13 of your subjects at The Chinese University of Hong Kong, plus 1,000+ more Bibles across the AskSia library.
Sia - your BMEG5720 tutor, unlimited, worked the way the exam marks it
The full 5-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works