PGEE11213 Chap.4 Instrument Choice and Point Quality
Instrument Choice and Point Quality
Capability belongs to the complete system
Instrument choice must account for surface condition, access, range, feature scale, fixturing, environment, operator and analysis software.
A sensor specification alone does not prove that the complete method can resolve the decision on the actual component.
Control optical capture geometry
Point quality depends on incidence angle, range and smooth probe motion. Reflective or dark surfaces can reduce reliable return, while edges and radii may require a changed orientation.
Repair capture conditions before applying stronger filters that remove evidence.
Match resolution to the feature
Very fine settings increase point count, overlap and processing burden without guaranteeing better decisions. Conduct a short study on the critical feature, compare local coverage and fitted results, and choose the least demanding setting that preserves the required geometry and uncertainty.
What this chapter covers
- 01
Surface preparation
- 02
Incidence angle
- 03
Probe range
- 04
Resolution choice
- 05
Reference artefacts
- 06
Capability evidence
Worked example · free
Repair poor points near a radius
- 2Recognise that the surface normal changes around the radius.
- 2Adjust probe orientation and keep a stable useful range.
- 2Repeat the region and compare coverage before filtering.
Key terms
- Incidence Angle
- Incidence Angle is the angle between the sensor direction and the normal of the measured surface.
- Point Quality
- Point Quality indicates whether captured optical data meets selected geometric or signal conditions.
- Reference Artefact
- A Reference Artefact is calibrated geometry used to test a measurement chain at a relevant scale and range.
Instrument Choice and Point Quality FAQ
Why does surface condition affect optical measurement?
Dust, oil, reflectivity and dark finishes alter the light returned to the sensor and can create gaps or scatter. Cleaning or surface treatment may improve capture, but treatment can also change the measured surface. Record preparation and test a representative region before committing to the production method.
Is the highest resolution setting always safest?
No. Fine settings can increase overlap, noise, processing time and sensitivity to surface effects without changing the fitted result. Compare the setting with the smallest relevant feature and tolerance, then inspect local spacing and repeatability. Use the lightest setting that preserves the engineering conclusion.
What does a calibrated artefact prove?
It can test scale, probing, alignment and environmental behaviour when its geometry and range resemble the task. Measure it through the same complete workflow. A successful check on unrelated geometry may show that the instrument functions but may not validate the feature algorithm or setup used on the component.
How should poor point quality be investigated?
Return to the raw observations before changing filters. Map invalid points, scatter and missing regions against surface material, incidence angle, stand-off, scan direction, motion and environmental conditions. Repeat a small controlled area while changing only one factor, then compare point spacing, residual spread and a stable reference feature.
Check calibration status and the complete optical path before blaming the component. If a coating or exposure change is necessary, record it as part of the method and verify that it does not alter the measurand. Deleting inconvenient points without a documented physical reason can hide bias and must not substitute for controlled capture.
Assessment move
Create a fault tree for one poor scan: surface, incidence, range, speed, overlap, exposure and filtering. Change only one factor per trial and predict whether it should repair gaps, scatter or both. Then plan a capability check with a reference artefact and state which parts of the production chain it validates. End by comparing point count with actual spatial resolution on the critical feature.
Sketch the probe ray and surface normal at a plane, a radius and a deep edge, then rank the expected incidence quality without relying on software colours. Design a controlled trial with one surface patch captured at two orientations and two resolutions; identify the metrics that would decide whether coverage, fitted size and extrema remain stable.
Contrast missing data with noisy data and assign a different first intervention to each. Next, choose a tactile and an optical route for the same component, listing feature access, deformation risk, reflectivity, coverage and cycle time. Include one shared reference feature that can reveal a frame disagreement.
Finish by drafting a process instruction with an explicit stop condition: if the quality indicator, coverage or reference check leaves the validated range, preserve raw data and escalate instead of applying stronger filtering until the display appears acceptable. Add an artefact trial at the low, middle and high ends of the working range and predict which scale or geometry effects might emerge.
Separate short-term repeatability from a reference bias in the results. Revisit surface treatment by listing what it improves and what physical change it may introduce. Compare a clean reflective surface, a coated surface and a tactile measurement without assuming one is automatically true.
Close by choosing the minimum evidence needed to release a new scan profile: critical-feature stability, coverage, repeat setup, reference check and documented settings.