AERO61021 Chap.5 Sensor Response Time and Dynamic Signals
Sensor Response Time and Dynamic Signals
Sensor Response Time and Dynamic Signals deals with measurements that change while you are taking them. The chapter first separates a time-varying record into a steady mean and a fluctuating part, the DC and AC components, and shows why sampling through time is essential when an average would conceal the behaviour of interest. It then models the sensor itself.
Most transducers behave as first-order systems, so their output approaches a sudden change in input along an exponential curve controlled by one time constant. You learn to recover that time constant from a data-sheet rise time quoted at a stated percentage, and to predict how long a reading needs to settle.
The last step drives the same sensor with a sinusoid: the output is attenuated by a magnitude ratio and delayed by a phase angle, and both grow with the product of time constant and angular frequency. Working these relations with consistent units and radians gives you a quantitative way to judge whether a sensor is fast enough for the signal you intend to record, a judgement that recurs in control and filter design.
Every worked number uses original values so the method can be rehearsed independently.
What this chapter covers
- 01
Periodic, quasi-periodic and transient signals
- 02
Mean and fluctuating components of a signal
- 03
First-order exponential response to a step input
- 04
Recovering a time constant from a rise time
- 05
Magnitude ratio for a sinusoidal input
- 06
Phase angle and time lag between input and output
- 07
Links to control loops and filter design
Worked example · free
Find a time constant from a 90% rise time and test a slow oscillation
- 2Use the rearranged first-order law with zero starting output: t/τ = −ln(1 − 0.90) = ln(10) = 2.303, so τ = 46 / 2.303 = 20.0 s.
- 1After one time constant the output reaches 1 − e^(−1), which is about 63% of the step.
- 1Angular frequency is ω = 2π × 0.02 = 0.126 rad/s, so τω = 20.0 × 0.126 = 2.51.
- 2The magnitude ratio is M = 1 / √(1 + 2.51²) = 1 / 2.70 = 0.37, so only about 37% of the input swing appears at the output.
Key terms
- Time constant
- The time constant is the parameter of a first-order system that sets how quickly its output approaches a new input level.
- Rise time
- Rise time is the time a sensor takes to reach a stated percentage of a step change in its input.
- Magnitude ratio
- The magnitude ratio is the fraction of an input oscillation's amplitude that survives at the sensor output.
- Phase lag
- Phase lag is the angle by which a sensor's output oscillation trails the input oscillation.
- Fluctuating component
- The fluctuating component is the zero-mean part of a signal left after its steady mean is removed.
Sensor Response Time and Dynamic Signals FAQ
Why does a slow sensor shrink an oscillating signal?
A first-order sensor is always chasing its input. When the input reverses before the output has caught up, the output turns back early and never reaches the full peak. The faster the oscillation relative to the time constant, the smaller the fraction that survives, which is what the magnitude ratio expresses through the product of time constant and angular frequency.
Does a 90% rise time equal the time constant?
No. For a first-order sensor the time constant is the time to about 63% of a step. A 90% rise time is about 2.3 time constants and a 95% figure about 3.0, so always divide by the logarithm that matches the quoted percentage before using the value in any further calculation.
What is the difference between DC and AC components?
The DC component is the steady mean of a record and the AC component is the oscillation about that mean, which averages to zero. Adding them reconstructs the original signal. Separating them helps because the mean describes the operating condition while the fluctuation carries unsteadiness, vibration or noise.
Assessment move
Build this chapter around one sensor and three questions: how long does it take to settle, how much of an oscillation does it pass, and how late is that oscillation. Begin by sketching a step response freehand and marking the 63% and 95% points at one and three time constants; if you can draw it from memory you can sanity-check any later answer.
Then practise the rearrangement of the first-order law until you can move between a rise time at any percentage and the time constant in one line, remembering that the logarithm term is negative and cancels the minus sign. Make a short table of percentage against multiples of τ for 50, 63, 90 and 95 percent and verify each entry yourself.
For oscillating inputs, always compute ω from f first and keep phase in radians when you divide by ω to obtain a time lag. Work the module notes' own check case, a time constant near 61 s at 0.011 Hz, and confirm you obtain a magnitude ratio of about 0.23, a lag near 77 degrees and a delay near 19 s; reproducing a known answer is the best proof your calculator is in the right mode.
Next, invent variations: halve the time constant, double the frequency, and predict the direction of change before calculating. For signals, practise decomposing a sketched periodic record into a mean and a fluctuation and explain in words what each part tells an experimenter.
In the laboratory and the group project, use these ideas to decide whether a chosen sensor can follow the phenomenon at all, and write that justification into your report rather than assuming every instrument responds instantly. As a last check, keep a one-page sheet listing the three relations for magnitude ratio, phase and time lag together with a fully worked example in your own numbers.
Reworking that sheet from a blank page each week is quicker than rereading notes and exposes slips in units or calculator mode immediately.