MECH60561 Chap.7 Dynamic Finite Element Problems
Dynamic Finite Element Problems
Dynamic Finite Element Problems adds mass, damping, initial conditions and time to the stiffness framework. Free vibration reveals natural frequencies and mode shapes through an eigenvalue problem. Forced vibration compares excitation frequency with natural response and explains resonance, while damping changes peak amplitude and decay.
The chapter also treats time-step selection, energy behaviour and the distinction between a physical mode and an unintended rigid-body motion. Frequency-unit conversion, modal participation and load-history definition keep a smooth numerical response from being mistaken for a complete dynamic explanation. Time-step refinement tests peak, phase and energy rather than trusting plot smoothness.
What this chapter covers
- 01
Undamped free vibration
- 02
Natural frequencies
- 03
Mode shapes
- 04
Forced response and resonance
- 05
Critical and under damping
- 06
Mass representation
- 07
Time marching and energy checks
Worked example · free
Calculate one natural frequency
- 3Divide stiffness by mass and take the square root for angular frequency.
- 3Divide by two pi for hertz and invert for the period.
- 2Compare forcing and natural frequency in matching units and state resonance sensitivity.
Key terms
- Mode shape
- The relative displacement pattern associated with a natural frequency.
- Resonance
- Large dynamic amplification when excitation lies near a natural response frequency under low damping.
- Time marching
- A numerical process that advances dynamic state variables through discrete times.
Dynamic Finite Element Problems FAQ
What does a near-zero frequency mean?
It can represent an intended rigid-body mode in a free-free model or an unintended missing constraint or disconnected part in a supported model. Inspect the mode shape, supports and connectivity before removing or ignoring it.
How does damping affect resonance?
In the simple linear response, more damping lowers and broadens the resonant peak and causes free vibration to decay faster. The damping model still needs physical justification or sensitivity testing because excessive numerical damping can suppress real response.
How should I choose a time step?
Base the step on the shortest important period the analysis must resolve and on the integration method. Repeat the calculation at a finer step and compare peak, phase, energy and frequency content. A smooth plot alone is not evidence of adequate resolution.
Exam move
Connect each dynamic quantity to the static framework. Stiffness stores strain energy, mass represents inertia and damping represents energy loss. Calculate single-degree natural frequency until conversion among radians per second, hertz and period is automatic. Then read multi-degree modes as relative shapes whose magnitude is arbitrary.
Inspect low modes for expected global motion and near-zero modes for missing support or disconnection. Practise forced-response sketches that place excitation below, near and above a natural frequency and state how damping changes the peak. For transient analysis, estimate important periods before choosing time step and duration.
Record initial displacement, velocity and the full load history because a step, impulse and ramp with the same peak can create different motion. Use energy behaviour and time-step refinement as independent numerical checks. Review errors under units, mass scale, support, mode interpretation, damping and resolution.
Finish every answer with the analysis type, frequency or time context and the physical meaning of the reported peak. Build a unit-conversion drill before modal interpretation. Given any angular frequency, calculate hertz and period, then reverse the calculation. Add a forcing frequency in a different unit and do not compare them until both use the same clock.
This prevents a false resonance claim caused by confusing radians with cycles. Next vary stiffness and mass separately and predict the square-root response. A doubled stiffness does not double natural frequency, and a doubled mass lowers it by a factor of the square root of two. For a multi-degree model, list the first several modes with a short physical label rather than only numbers.
Inspect whether each shape respects supports and connectivity. A near-uniform translation in a fixed-base model points to missing restraint or disconnection. Close or repeated frequencies require comparison of the modal subspace rather than sign-sensitive point checks, because eigenvector signs and combinations are not unique. For harmonic response, sketch amplification against frequency ratio at two damping levels.
State where the peak lies, what damping changes and which mode dominates. Confirm that the applied load can actually excite that mode through spatial participation. A natural frequency alone does not guarantee a large response. For transients, derive the time-step target from the shortest important period and repeat at a finer resolution. Compare peak magnitude, time of peak, phase and energy behaviour.
Run long enough to distinguish initial transient from continuing forced response. Review the complete load history and initial conditions; a hidden ramp changes frequency content. Track total model mass and its distribution because an apparently correct static model can have poor dynamic properties. Finish each dynamic report with the mass model, damping assumption, frequency or time resolution and a sensitivity statement.