University of Glasgow · FACULTY OF ENGINEERING

ENG4179 Chap.3 Sorption Storage and Heat Upgrading

- one subject, every graph, every model, every mark
6 Chapters3-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 3 of 9 · ENG4179

Sorption Storage and Heat Upgrading

Sorption Storage and Heat Upgrading follows a sorbate and sorbent through charging, separated storage and heat-releasing discharge. Adsorption acts at a surface, while absorption acts within another phase. Reaction enthalpy sets an ideal capacity, but conversion, transport and heat-exchanger effectiveness determine useful delivery.

Pressure and temperature levels connect the reactor to evaporation or condensation and can support heat upgrading when every energy input remains inside the boundary. A complete cycle account locates the sorbate after charge, storage and discharge.

Separate rows should record regeneration heat, low-grade source heat, useful reactor heat, condenser rejection and auxiliary work, with every performance ratio naming its numerator and denominator. Recalculate a bed after changing only reacted fraction, exchanger effectiveness or discharge time so capacity and power effects remain distinct.

Sketch equilibrium pressure against temperature qualitatively and predict whether warming the condenser or cooling the reactor supports the intended step. Compare two faults: adequate material capacity with slow mass transfer, and fast reaction with poor bed conduction. Pressure history, sorbate flow, internal temperature gradient and water-loop heat rate help separate them.

For adsorption, relate pore access and particle size to pressure drop; for absorption, relate solution concentration and circulation to exchanger duty. A separated store near ambient can reduce thermal standing loss without eliminating leakage, parasitic power or degradation. Include cycling decline when assessing long-term active capacity.

A strong recommendation identifies the material state, controlling equilibrium, transport bottleneck, external heat-transfer path and delivery temperature. If a heat-output ratio exceeds one, explain the low-grade source contribution instead of treating the number as a conservation failure. The final intervention should target a named mechanism and specify the measurement that would verify improvement.

In this chapter

What this chapter covers

  • 01

    Adsorption

  • 02

    Absorption

  • 03

    Desorption charge

  • 04

    Separated storage

  • 05

    Sorption discharge

  • 06

    Heat upgrading

Worked example · free

Estimate sorption-bed delivery

Q [7 marks]. Calculate theoretical, reacted and useful heat from a bed with stated conversion and delivery efficiency.
The loop separates sorbent and sorbate during charging, preserves the separated states, then releases heat when sorption resumes.The loop separates sorbent and sorbate during charging, preserves the separated states, then releases heat when sorption resumes.chargedesorb vapourstoreseparate statesdischargesorb and heatreset material pair
The loop separates sorbent and sorbate during charging, preserves the separated states, then releases heat when sorption resumes.
  • 4Multiply active mass by reaction enthalpy and reacted fraction.
  • 3Apply heat-exchanger delivery and convert energy to average power.
The chapter separates material conversion from heat-transfer delivery so improvement targets remain distinct. The marks are original revision weighting, not a university scheme.
Sia tip — Do not merge reaction conversion and heat-exchanger efficiency into an unexplained loss.
Glossary

Key terms

Sorbent
The material that takes up another substance by adsorption or absorption.
Sorbate
The substance taken up by a sorbent during a sorption process.
Reaction extent
A measure of how far a specified reaction or sorption transition has progressed.
FAQ

Sorption Storage and Heat Upgrading FAQ

How do adsorption and absorption differ?

Adsorption concentrates molecules on a surface, while absorption distributes them within another phase. Their transport, equipment and pressure-drop considerations therefore differ, so equipment assumptions must follow the identified mechanism.

Why can standing loss be small?

After charging separates the material pair, energy can remain as chemical potential near ambient temperature instead of relying on a continuously hot body. Leakage and degradation can still occur.

What limits discharge power?

Mass transfer, reaction kinetics, equilibrium pressure, bed thermal conductivity and heat-exchanger area can all restrict how quickly stored reaction energy reaches the load. Measuring the discharge curve helps locate the active limit.

Study strategy

Exam move

Draw the sorption cycle as three states: charging separates the pair, storage preserves separation, and discharge reunites sorbate and sorbent while releasing heat. Beside each arrow, write the heat and mass transfer that drives it. Keep ideal reaction capacity, reacted fraction and useful delivery as separate lines in numerical work.

Practise identifying whether a proposed improvement addresses kinetics, mass transfer, bed heat transfer or external heat exchange. Compare adsorption and absorption through molecule location rather than memorised equipment names. For heat-upgrading questions, label source heat, regeneration heat, useful heat and auxiliary work before quoting any performance ratio.

End each answer with the required pressure and temperature conditions, because a capacity total alone does not prove that a cycle can deliver the requested temperature. Add a state table containing sorbent condition, sorbate location, pressure, temperature and heat interaction. During charging, identify the heat that drives desorption and where the released sorbate is collected.

During storage, state how the separated pair is isolated. During discharge, show how sorbate reaches the reactor and where useful heat leaves. Practise theoretical capacity from active mass and reaction enthalpy, then add conversion, inactive mass and delivery effectiveness separately. Calculate average power only after useful energy is known and time is in seconds.

Compare the average with any peak requirement instead of assuming a smooth discharge. Review adsorption through surface area, pore transport and bed thermal contact. Review absorption through solution concentration, circulation and liquid heat exchange. This prevents similar terminology from hiding different equipment.

For temperature upgrading, include low-grade source heat, regeneration heat and auxiliary work inside the boundary. Write any coefficient denominator in words. Explore equilibrium qualitatively by changing reactor, evaporator or condenser temperature and predicting the pressure consequence.

Pair each improvement with a penalty: smaller particles can aid mass transfer but raise pressure drop; extra fins improve heat transfer but displace active material; higher regeneration temperature can improve conversion but demand a better source. Add cycling degradation to the capacity chain so initial performance is not presented as lifetime performance.

Use a diagnostic sequence when useful power is low: verify sorbate inventory, equilibrium driving force, mass transfer, reaction conversion, bed conduction and external heat exchange. A final recommendation should locate the limiting component, propose one measurable intervention and state the temperature and pressure conditions under which the promised heat can actually be delivered.

A+Everything unlocked
Unlocks this Bible + all 26 of your subjects at University of Glasgow, plus 1,000+ more Bibles across the AskSia library.
Sia - your ENG4179 tutor, unlimited, worked the way the exam marks it
The full 3-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works