University of Glasgow · FACULTY OF ENGINEERING

ENG4179 Chap.4 TES Exergy and Flexibility

- one subject, every graph, every model, every mark
6 Chapters4-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 4 of 9 · ENG4179

TES Exergy and Flexibility

TES Exergy and Flexibility asks whether stored heat is useful at the required temperature and time. Energy measures quantity, while exergy measures ideal work potential relative to an environment. Conversion irreversibility is separated from enclosure heat loss.

Flexibility requires charging power, holding duration, discharge power and temperature compatibility, so an energy-capacity number cannot by itself prove that a community, underground or industrial store can meet its service. Revision should maintain parallel energy and exergy ledgers.

The energy ledger follows quantities through charge, holding, discharge and conversion; the exergy ledger adds the temperature of each interaction and one declared environment. Compare equal-energy stores at several delivery temperatures and explain why work potential falls as heat approaches ambient, while recognising that low-temperature heat can still suit a matching load.

Draw flexibility events with surplus start time, available power, charging limit, holding interval, demand peak and discharge limit. Integrate only the power the store can accept. On discharge, apply stated losses, divide by load with consistent units and verify temperature sufficiency. Contrast a short high-power peak with a long low-power duty to expose different services at equal capacity.

For underground options, include geology, well spacing, pumping, distribution temperature and seasonal loss; for community systems, add network length, diversity and coincident peak demand. State whether a round-trip figure returns heat or electricity and whether conversion equipment and auxiliaries sit inside its boundary. Vary the dominant uncertain input rather than reporting one precise estimate.

A defensible conclusion reports usable capacity, charge rate, discharge rate, temperature and duration, then identifies the field measurement needed for any ungrounded term.

In this chapter

What this chapter covers

  • 01

    Thermal exergy

  • 02

    Reference environment

  • 03

    Conversion irreversibility

  • 04

    Charging power

  • 05

    Discharge duration

  • 06

    System flexibility

Worked example · free

Compare equal heat at two temperatures

Q [6 marks]. Estimate ideal exergy when equal energy is supplied at different temperatures above one environment.
Equal energy bars can carry unequal exergy: useful-work potential falls as stored heat approaches the environmental temperature.Equal energy bars can carry unequal exergy: useful-work potential falls as stored heat approaches the environmental temperature.100 energy60 exergy100 energylowerexergyhigh temperaturelow temperature
Equal energy bars can carry unequal exergy: useful-work potential falls as stored heat approaches the environmental temperature.
  • 3Convert all temperatures to kelvin and calculate the ideal work fraction.
  • 3Multiply by heat quantity and interpret against the required service.
Higher-temperature heat has more ideal work potential, but lower-temperature heat may still suit a matching load. The marks are original revision weighting, not a university scheme.
Sia tip — Use one environmental reference and absolute temperature for both alternatives.
Glossary

Key terms

Reference environment
The ambient condition relative to which exergy and equilibrium are evaluated.
Round-trip efficiency
Useful energy recovered divided by energy supplied across a complete storage cycle.
Flexibility
Ability to shift energy in time while meeting required rate, duration and quality.
FAQ

TES Exergy and Flexibility FAQ

Can equal energy stores have different value?

Yes. Temperature level changes work potential and load compatibility, while power and timing determine whether the energy can be used when demanded. Compare all three before selecting a store.

What does thermal exergy measure?

It estimates the maximum useful work obtainable as heat is brought reversibly toward environmental equilibrium. Real equipment produces less because irreversibility remains in each conversion component.

How is duration estimated?

Divide usable delivered energy by required discharge power, then verify that temperature and hardware can sustain that power over the calculated interval. Otherwise the duration is only an energy estimate.

Study strategy

Exam move

Keep three columns in every system comparison: energy quantity, temperature quality and time-rate service. Use kelvin when applying an exergy relation and state the environmental reference. Draw conversion equipment and storage enclosure separately so heat leakage is not confused with turbine, compressor or heat-exchanger irreversibility.

For flexibility questions, calculate usable energy after losses, divide by load only after units match, and add a temperature-sufficiency check. Rework one problem with unchanged capacity but lower charging power to see why surplus capture falls. Rework another with equal energy at different temperatures to explain exergy.

In written recommendations, name the service and site constraint before choosing underground, community-scale or shorter-duration storage. A technology label is never a substitute for a complete duty statement. Maintain separate energy and exergy ledgers. The energy ledger follows quantities through charge, holding, discharge and conversion. The exergy ledger adds each interaction temperature and one reference environment.

Recalculate equal-energy cases at several delivery temperatures so the fall in work potential near ambient becomes intuitive. Connect each result to a load, because modest-exergy heat can still be valuable for a matching district loop. Build flexibility event diagrams containing surplus start time, available power, charging limit, holding interval, demand peak and discharge limit. Integrate only the power the store can accept.

On discharge, reduce energy by the stated losses, divide by load with consistent units and verify that temperature remains adequate. Compare a short high-power peak with a long low-power duty to show why equal capacities provide different services. For underground cases, add geology, well spacing, pumping, distribution temperature, seasonal loss and monitoring.

For community systems, add diversity, network length and peak coincidence. Ask whether round-trip efficiency returns heat or electricity and whether pumps, compressors and conversion equipment are inside its boundary. Practise identifying the dominant uncertainty and varying it rather than repeating one central estimate.

A complete conclusion reports usable capacity, maximum charge rate, discharge rate, delivery temperature and duration. If one is ungrounded, name the field measurement or test needed. This creates a conditional engineering recommendation instead of a capacity-only promise.

A+Everything unlocked
Unlocks this Bible + all 26 of your subjects at University of Glasgow, plus 1,000+ more Bibles across the AskSia library.
Sia - your ENG4179 tutor, unlimited, worked the way the exam marks it
The full 4-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works