PHYS5044 Chap.3 Magnetic Sensing, Bridges and Null Measurements
Magnetic Sensing, Bridges and Null Measurements
Magnetic Sensing, Bridges and Null Measurements covers the sensors that turn a magnetic field into a voltage and the circuits that measure very small fractional changes. The Hall plate comes first: the Lorentz force pushes carriers to one edge of a thin slab until an electric field across the width balances it, giving a voltage proportional to drive current and flux density and inversely proportional to thickness.
Because nothing in that balance needs the field to change, a Hall plate reads steady fields, while an induction coil responds to the rate of change of field and gives no output at zero frequency. Magnetoresistive bridges complete the comparison. The second half turns to resistance changes of a part in a thousand, such as a strain gauge under load.
A Wheatstone bridge cancels the large unchanging part so that only the change appears; ratiometric readout ties the converter reference to the excitation so that supply drift cancels; and the null method reads the answer from a calibrated resistor at balance, independent of gain and excitation. Worked numbers follow one strain gauge from microstrain to converter code.
What this chapter covers
- 01
How the Lorentz force produces a Hall voltage
- 02
Hall plate, induction coil and magnetoresistive sensors compared
- 03
Frequency response of field sensors
- 04
Quarter bridge output and its small-signal form
- 05
Ratiometric readout and supply cancellation
- 06
Null balance with a calibrated resistor
Worked example · free
Work backwards from a bridge reading to strain
- 1Write the exact output as Vout = Vex x / (2(2 + x)) and set it equal to 1.00 mV with Vex = 2.5 V.
- 2Rearrange: 2.5x = 0.002(2 + x), so x = 0.004 / 2.498 = 1.6013 × 10−3.
- 1Divide by the gauge factor: strain = 1.6013 × 10−3 / 2.1 = 762.5 microstrain.
- 1The small-signal form x = 4Vout/Vex gives 1.6000 × 10−3, or 761.9 microstrain, which is 0.08% low.
Key terms
- Hall coefficient
- A material constant linking the Hall field to current density and flux density; it is large when carriers are few.
- Gauge factor
- The ratio of fractional resistance change to strain for a strain gauge, about 2 for metal foil.
- Ratiometric measurement
- A readout that expresses a sensor output as a fraction of the same reference that drives it, so drift in that reference cancels.
- Null measurement
- A method in which a calibrated element is adjusted until a detector reads zero, so the answer comes from that element rather than a gain.
- Quarter bridge
- Wheatstone bridge with one active sensing arm and three fixed resistors of equal value, giving about a quarter of the excitation times the fractional change.
Magnetic Sensing, Bridges and Null Measurements FAQ
Why is a Hall plate made thin?
The Hall voltage is inversely proportional to the thickness of the plate, so a thinner plate gives more output for the same drive current and field. Semiconductors are chosen for the same reason: few carriers mean a large Hall coefficient and therefore a larger voltage per tesla.
When should I use an induction coil instead of a Hall sensor?
Use a coil when the field changes quickly and no power supply is wanted. Its output is proportional to the rate of change of field, so it rises with frequency and can be very quiet at high frequency, but it reads nothing for a steady field.
Why put a strain gauge in a bridge?
The gauge changes by about a part in a thousand, which is tiny next to its full resistance and next to supply drift. A balanced bridge cancels the unchanging part so only the change appears at the output, where an instrumentation amplifier can raise it before conversion.
What does ratiometric readout cancel?
It cancels changes in the excitation. The bridge output is proportional to the excitation, so if the converter uses that same voltage as its reference, a sag in the supply scales signal and reference together and the digital code stays the same. A fixed reference would pass the drift through.
Why does a null method give the best precision?
At balance the detector reads zero, so its gain and the excitation only affect how sharply the zero is found. The result comes from a calibrated resistor, which can be very stable, so drifts elsewhere in the circuit drop out. The cost is speed, because each zero must be found.
Exam move
Draw the Hall plate from memory with current, field, charge build-up and the voltage across the width, then write the voltage formula and say what each design lever does. Build a three-column comparison of Hall plate, induction coil and magnetoresistive sensor by frequency behaviour.
For bridges, derive the quarter-bridge output once, then practise forward and backward calculations between microstrain and millivolts with the exact and small-signal forms. Finish by explaining in two sentences each why ratiometric readout cancels supply drift and why a null measurement is independent of gain, because those explanations are asked for in words.
Then take one sensing task, such as a steady current or a vibrating field, and justify a sensor choice by its frequency response rather than by its responsivity alone.
Working through Magnetic Sensing, Bridges and Null Measurements in PHYS5044? Sia is AskSia’s AI Physics tutor — ask any PHYS5044 Magnetic Sensing, Bridges and Null Measurements question and get a clear, step-by-step explanation grounded in how PHYS5044 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.