PHYS5044 Chap.7 Operational Amplifier Configurations
Operational Amplifier Configurations
Operational Amplifier Configurations covers the circuits that turn a raw sensor output into a clean, scaled voltage. An op amp multiplies the difference between its inputs by a very large open-loop gain, and negative feedback lets external components fix the result. The chapter builds the standard stages from two working assumptions: no current flows into the inputs, and the two inputs settle at the same voltage.
From those it derives the inverting and non-inverting gains, the unity-gain follower used to stop a sensor being loaded, the summing stage, the difference stage that rejects a voltage shared by both inputs, and the integrator whose output ramps at a rate set by the input and the RC product.
It then removes the infinite-gain assumption, showing that the closed-loop gain equals one over the sum of the inverse open-loop gain and the feedback fraction, so a high-gain stage needs far more open-loop gain than a buffer for the same accuracy. Resistor mismatch in a difference stage and rail saturation in an integrator close the chapter as the two practical limits students most often overlook.
What this chapter covers
- 01
Two working assumptions under negative feedback
- 02
Inverting, non-inverting and follower gains
- 03
Finite open-loop gain and the feedback fraction
- 04
Difference stages and common-mode rejection
- 05
Integrator ramps, slopes and rail saturation
- 06
A fixed order of work for any op amp circuit
Worked example · free
How much open-loop gain a gain of 250 really needs, and up to what frequency
- 1The feedback fraction is R1/(R1 + Rf) = 1/250, so the ideal gain is 250 and G = 1/(1/Av + 1/250).
- 1The fractional error is (250/Av)/(1 + 250/Av); setting it to 0.001 gives Av = 250 × 0.999/0.001 = 249,750.
- 1The open-loop gain is 107/f, so 107/f ≥ 249,750 holds only below f = 40 Hz.
- 2Two stages of √250 = 15.81 each, allowed 0.05% apiece, need Av ≥ 15.81 × 0.9995/0.0005 = 31,600, which holds below 107/31,600 = 316 Hz.
Key terms
- Open-loop gain
- The amplification an op amp applies to its input difference with no feedback connected, often 105 or more at DC.
- Feedback fraction
- This is the share of the output voltage returned to the inverting input, set by the feedback network.
- Virtual ground
- An inverting input held at zero volts by feedback even though it is not wired to ground.
- Common-mode rejection ratio
- Differential gain divided by common-mode gain, usually quoted in decibels for a difference stage.
- Voltage follower
- A unity-gain non-inverting stage that copies a voltage while drawing almost no current from its source.
Operational Amplifier Configurations FAQ
Why can I assume both op amp inputs sit at the same voltage?
With negative feedback the output moves until the input difference is tiny, because any remaining difference is multiplied by a very large open-loop gain. The assumption fails if the output hits a supply rail or the feedback is positive, so check both before relying on it.
When does a finite open-loop gain matter?
It matters when the closed-loop gain is high or the accuracy target is tight. The fractional error is about the ideal gain divided by the open-loop gain, so a gain of several hundred with a modest op amp can miss its target by a few percent.
What does a voltage follower actually gain me?
It has no voltage gain, but it presents a very high input resistance to the sensor and a very low output resistance to the next stage. A sensor with a large internal resistance therefore keeps its full voltage instead of being divided down by the load.
Why do resistor tolerances matter in a difference stage?
Common-mode cancellation depends on two resistor ratios being equal. A one percent mismatch can let a large shared voltage through with a gain near one hundredth, which may be comparable to the wanted millivolt signal. Matched resistor networks or a trim fix this.
How do I find when an integrator saturates?
For a steady input the output changes at minus the input voltage divided by RC. Divide the voltage headroom to the rail by that slope to get the time to saturation, and add a reset switch or a large resistor across the capacitor so offsets cannot drive it there.
Exam move
Start by deriving the inverting and non-inverting gains from the two working assumptions until each takes under a minute. Then redo them with impedances so the integrator and a low-pass stage follow from the same steps. Next, practise the finite-gain formula: pick a feedback fraction, compute the closed-loop gain for three open-loop gains and express each error as a percentage, keeping the sign.
Work one difference stage with a deliberately mismatched resistor and find the common-mode leak and the rejection ratio in decibels. Finish each problem by checking the output against the supply rails.
Once those feel routine, mix the stages: put a follower after a high-resistance sensor, a difference stage after a bridge, then an integrator, and trace one voltage through all three, writing the gain, the sign and the unit at every arrow.
Working through Operational Amplifier Configurations in PHYS5044? Sia is AskSia’s AI Physics tutor — ask any PHYS5044 Operational Amplifier Configurations question and get a clear, step-by-step explanation grounded in how PHYS5044 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.