University of Glasgow · FACULTY OF PHYSICS

PHYS5044 Chap.6 Spectroscopy and Imaging at Extreme Wavelengths

- one subject, every graph, every model, every mark
6 Chapters3-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 6 of 12 · PHYS5044

Spectroscopy and Imaging at Extreme Wavelengths

Spectroscopy and Imaging at Extreme Wavelengths follows measurement beyond the visible band, out to thermal infrared and in to X-rays. One relation ties the chapter together: transmitted intensity falls exponentially with the product of an attenuation coefficient, a concentration and a path length, with separate terms for absorption and scattering.

Gas sensing uses it with the path known and the concentration unknown; gases have narrow line spectra, so a laser tuned on and off a line, or a scrubbed reference sample, supplies the incident intensity and drifts cancel in the ratio. Radiography uses the same law with the material known and the thickness unknown, and the half-value thickness shows why softer X-rays give more contrast but fewer transmitted photons.

Thermal imaging relies on emitted rather than transmitted light: the Wien law places the peak of a black body at about 10 µm for room temperature objects, and a hot target is often easiest to spot at shorter wavelengths where its background is faint. Resolving power, the wavelength divided by the smallest separable interval, links spectrometer design to the lines you need to split.

In this chapter

What this chapter covers

  • 01

    The attenuation law with absorption and scattering terms

  • 02

    Obtaining the incident intensity in gas sensing

  • 03

    X-ray attenuation and half-value thickness

  • 04

    Black-body emission and the Wien peak

  • 05

    Choosing an infrared band for contrast

  • 06

    Resolving power and grating size

Worked example · free

Judge X-ray energies for a 10 mm aluminium plate from the attenuation curves

Q [6 marks]. This weighting is a study guide choice; it is not the University allocation. Use the attenuation curves for aluminium at 30 keV and 50 keV, whose half-value thicknesses are 2.28 mm and 6.98 mm. For a plate 10 mm thick, find the transmitted fraction at each energy and the fractional drop in signal caused by an extra 1 mm of metal, then recommend an energy for spotting thickness variations. AskSia set these marks for practice only; they are not the University's official weighting.
Transmitted fraction of a narrow X-ray beam against aluminium thickness at 30 keV and 50 keV; dashed lines mark the half-value thickness of each beam, 2.28 mm aTransmitted fraction of a narrow X-ray beam against aluminium thickness at 30 keV and 50 keV; dashed lines mark the half-value thickness of each beam, 2.28 mm and 6.98 mm.2.28 mm6.98 mm010200.51.030 keV50 keValuminium thickness in mmtransmitted fraction
Transmitted fraction of a narrow X-ray beam against aluminium thickness at 30 keV and 50 keV; dashed lines mark the half-value thickness of each beam, 2.28 mm and 6.98 mm.
  • 1Recover the coefficients: μ = ln 2 / half-value thickness, giving 3.04 per cm at 30 keV and 0.99 per cm at 50 keV.
  • 2Through 1.0 cm the fractions are e−3.04 = 0.048 at 30 keV and e−0.99 = 0.37 at 50 keV.
  • 2An extra 0.1 cm multiplies the signal by e−0.304 = 0.74 at 30 keV, a 26% drop, and by e−0.099 = 0.91 at 50 keV, a 9.5% drop.
  • 1The softer beam gives almost three times the contrast but passes under 5% of the photons, so choose 30 keV only if the source is bright enough; otherwise 50 keV.
About 4.8% passes at 30 keV and 37% at 50 keV; 1 mm extra cuts the signal by 26% and 9.5% respectively, so 30 keV wins on contrast if photons allow.
Sia tip — Contrast per millimetre is the coefficient itself, so the steeper curve always shows thickness changes more strongly.
Glossary

Key terms

Half-value thickness
The thickness of a material that transmits exactly half of a narrow incident beam, equal to ln 2 divided by the attenuation coefficient.
Line spectrum
An absorption pattern made of narrow, separated features, typical of gases at low pressure where molecules rarely collide.
Wien displacement law
Rule giving the wavelength of peak black-body emission as a constant of 2.898 × 10−3 m K divided by temperature.
Resolving power
Ratio of a wavelength to the smallest wavelength interval a spectrometer can separate at that wavelength.
Scrubbed reference
Sample of the same air with the target gas removed, used to supply the incident intensity for the ratio.
FAQ

Spectroscopy and Imaging at Extreme Wavelengths FAQ

Why do gas sensors often use lasers rather than LEDs?

Gas molecules collide rarely, so their absorption appears as narrow lines. A narrow laser line can sit exactly on one of those features and be strongly absorbed, while a broad LED spectrum would spread most of its power between lines where the gas hardly absorbs.

How is the incident intensity found in a gas measurement?

It must come from a reading with no absorption by the target gas but the same optics. Common choices are a wavelength just off the absorption line, or the same sample after the gas has been removed. Taking the ratio then cancels lamp drift and window losses.

Why do thermal cameras work near ten micrometres?

Objects near room temperature emit most strongly at around that wavelength, as the Wien law predicts for roughly 300 K. A camera there sees emitted heat rather than reflected light, so warm skin, leaking windows or hot machinery stand out without any illumination.

Are softer X-rays always better for radiography?

They show thickness changes more strongly because the attenuation coefficient is larger, but they also let fewer photons through. For thick or dense objects the transmitted signal can become too weak and noisy, so a harder beam may give the better image overall.

What sets the resolving power of a grating?

It equals the diffraction order times the number of grating lines that are illuminated. Filling more of the grating with a collimated beam, or working in a higher order, therefore raises the resolving power and lets closer spectral lines be separated.

Study strategy

Exam move

Begin with the attenuation law and practise inverting it for each unknown in turn: concentration, path length and coefficient. For every gas problem, write down first which reading plays the part of the incident intensity. Then work the X-ray case: compute half-value thicknesses from coefficients and back again, and estimate the contrast an extra millimetre produces.

Use the Wien law for three temperatures, from a room to a furnace, and compare where each peak falls with common detector bands. Finish with resolving power, finding the lines a grating must illuminate to split a close pair, and state each result as a decision rather than a bare number. Then redo one problem with a different gas, metal or temperature and predict the direction of each change before calculating.

Working through Spectroscopy and Imaging at Extreme Wavelengths in PHYS5044? Sia is AskSia’s AI Physics tutor — ask any PHYS5044 Spectroscopy and Imaging at Extreme Wavelengths question and get a clear, step-by-step explanation grounded in how PHYS5044 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 26 of your subjects at University of Glasgow, plus 1,000+ more Bibles across the AskSia library.
Sia - your PHYS5044 tutor, unlimited, worked the way the exam marks it
The full 3-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works