ELEC1130 Chap.4 Superposition and Thevenin Models

- one subject, every graph, every model, every mark
6 Chapters4-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 4 of 9 · ELEC1130

Superposition and Thevenin Models

Superposition and Thevenin Models simplify linear circuits without losing their terminal behaviour. Superposition isolates each independent source and adds signed voltage or current responses. A Thevenin model uses open-circuit voltage and the resistance seen at a chosen terminal pair.

Load calculations and limiting cases then verify the equivalent against the original network.

Superposition applies to linear voltage and current responses. Analyse one independent source at a time while replacing every other independent ideal source by its zero-value model. A zeroed ideal voltage source is a short circuit; a zeroed ideal current source is an open circuit. Preserve dependent sources if they exist.

Record each partial response against the same original arrow or polarity and add the signed values. Do not superpose power directly, because squaring or multiplying responses introduces cross-terms that are absent from a simple sum.

A Thevenin model belongs to a specified pair of terminals. Remove the load and calculate the open-circuit voltage with its stated polarity.

Next find the resistance looking into those terminals after deactivating independent sources, or apply a test source when the circuit demands it. Reconnect the load only when both parameters are established. The simplified source-plus-resistance network must then reproduce the original load voltage and current, although it need not reproduce internal branch quantities.

Use limiting cases as model checks.

Infinite load resistance should give zero current and the open-circuit voltage. A shorted load should give zero terminal voltage and the short-circuit current. Maximum resistive load power occurs when load resistance equals Thevenin resistance, but that condition delivers only half the generated power to the load. Distinguish maximum power from maximum efficiency or voltage fidelity before recommending a connection.

In this chapter

What this chapter covers

  • 01

    Linear response

  • 02

    Source deactivation

  • 03

    Signed superposition

  • 04

    Open-circuit voltage

  • 05

    Thevenin resistance

  • 06

    Maximum power transfer

Worked example · free

Find a Thevenin equivalent

Q [6 marks]. A linear network consists of a 12 V source feeding 2 kilohms to terminal a, with 4 kilohms from a to terminal b. Construct its Thevenin equivalent at a-b, attach a 2-kilohm load and verify the terminal voltage directly in the original circuit. These marks are an original practice allocation, not a published university marking scheme.
The flow separates one linear network into single-source cases, preserves the response sign in each case, and recombines those signed contributions at the choseThe flow separates one linear network into single-source cases, preserves the response sign in each case, and recombines those signed contributions at the chosen branch.linear networktwo sourcessource A alonesource B alonesigned responseA + B
The flow separates one linear network into single-source cases, preserves the response sign in each case, and recombines those signed contributions at the chosen branch.
  • 2Open-circuit voltage is 8.0 V.
  • 2Deactivation places 2 kilohms parallel 4 kilohms, giving 1.333 kilohms.
  • 2The 2-kilohm loaded voltage is 4.80 V.
Vth is 8.0 V, Rth is 1.333 kilohms and the 2-kilohm loaded voltage is 4.80 V. Direct reduction of the original divider produces the same terminal result.
Sia tip — Remove the load for voltage and deactivate independent sources for resistance.
Glossary

Key terms

Source deactivation
Source deactivation sets an independent ideal source to zero using its ideal internal model.
Thevenin voltage
Thevenin voltage is the open-circuit voltage at a specified terminal pair.
Test source
A test source probes terminal voltage-current response while dependent sources remain active.
FAQ

Superposition and Thevenin Models FAQ

Does superposition apply to power?

No. Add signed voltage or current responses first, then calculate nonlinear power from the total. Squaring each source contribution separately and adding those powers generally misses cross-terms and gives the wrong result.

What replaces a zeroed voltage source?

When an ideal voltage source is assigned zero volts, it becomes a short circuit because its terminal voltage is fixed at zero. By contrast, a zeroed ideal current source becomes an open circuit.

Where is a Thevenin model valid?

It reproduces behaviour only at the stated terminal pair within the linear assumptions. Moving the load to another pair usually changes both the open-circuit voltage and the resistance seen from that port.

How can I verify a Thevenin equivalent?

Use the equivalent and original network to predict voltage or current for two different loads. Agreement at both points tests the open-circuit intercept and the terminal resistance together.

What happens to dependent sources?

Dependent sources remain active when independent sources are deactivated. Apply a test source at the terminal pair and divide its voltage by the resulting current to find resistance.

Is maximum power transfer always best?

No. Equal source and load resistances maximise resistive load power but deliver only half the generated power to the load. Voltage accuracy and efficiency usually require different resistance relationships.

What does source transformation preserve?

It preserves the terminal voltage-current relation when source value, resistance and reference direction are transformed consistently. It does not claim that every internal branch current remains identical.

Which limits check a Thevenin model?

An infinite load should recover open-circuit voltage and zero current, while a short load should give zero terminal voltage and the predicted short-circuit current under the same reference polarity.

Why state the terminal pair?

The equivalent parameters belong to one identified port. Moving the load to different nodes changes the open-circuit voltage and resistance seen there, even when the original internal network has not changed.

Study strategy

Exam move

Draw a new circuit for every single-source case and keep the original response arrow. For Thevenin work, separate the open-circuit and deactivated-source states. Reconnect the load only after both parameters are known. Check open- and short-load limits, then solve the original circuit directly for one load as an independent verification.

Working through Superposition and Thevenin Models in ELEC1130? Sia is AskSia’s AI Electrical Engineering tutor — ask any ELEC1130 Superposition and Thevenin Models question and get a clear, step-by-step explanation grounded in how ELEC1130 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 8 of your subjects at University of Leeds, plus 1,000+ more Bibles across the AskSia library.
Sia - your ELEC1130 tutor, unlimited, worked the way the exam marks it
The full 4-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial