University of Leeds · FACULTY OF ELECTRICAL ENGINEERING

ELEC1130 Chap.1 Voltage, Current and Resistance

- one subject, every graph, every model, every mark
6 Chapters3-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 1 of 9 · ELEC1130

Voltage, Current and Resistance

Voltage, Current and Resistance establishes the reference language used throughout circuit analysis. Current is the rate of charge flow, voltage compares potential between two points, and resistance links the voltage across a component with the current through it under stated conditions.

The chapter also distinguishes series ammeter placement from parallel voltmeter placement and interprets negative results against chosen arrows.

A reference direction is a deliberate mathematical choice, not a prediction. Mark a branch-current arrow and a voltage polarity before applying a component relation.

If the calculated current is negative, retain the sign through every later equation and conclude that the physical flow opposes the arrow. This discipline prevents a convenient sign change from breaking KCL, KVL or power calculations. For an ohmic resistor, use the voltage across that resistor and the current through the same resistor.

A node voltage elsewhere in the network cannot be divided by a resistance unless those two quantities describe the same terminals and branch.

Measurement belongs inside the circuit model. An ammeter enters the current path in series and ideally has very small resistance. A voltmeter compares two nodes in parallel and ideally has very large resistance.

Real meters are finite, so their connection can change the quantity being observed. Estimate the expected scale, choose a safe range and decide what loading direction is plausible before energising a laboratory circuit. After taking a reading, compare it with the predicted sign, unit and order of magnitude.

This prediction-measurement-explanation loop turns a displayed number into evidence about the component and the chosen model.

Unit control provides a second independent check. Convert milliamps to amps and kilohms to ohms before substitution, keep full precision during intermediate work, and restore the most readable prefix only in the final line.

Voltage divided by resistance must produce current; voltage multiplied by current must produce power. When the unit does not match the requested quantity, revisit the equation before blaming the calculator.

In this chapter

What this chapter covers

  • 01

    Charge flow and current

  • 02

    Potential difference

  • 03

    Ohm's law

  • 04

    Reference directions

  • 05

    Ammeter placement

  • 06

    Voltmeter loading

Worked example · free

Infer resistance from a measured operating point

Q [4 marks]. A bench measurement shows a resistor carrying 20 mA at 6.0 V with current entering the positive-labelled terminal. Find resistance and predict current at 9.0 V if it remains ohmic. State the unit conversion and the current direction. These marks are an original practice allocation, not a published university marking scheme.
The straight current-voltage line passes through the measured point; its constant slope shows linear behaviour and corresponds to the reciprocal of resistance.The straight current-voltage line passes through the measured point; its constant slope shows linear behaviour and corresponds to the reciprocal of resistance.6 V20 mAslope = 1/Rvoltagecurrent
The straight current-voltage line passes through the measured point; its constant slope shows linear behaviour and corresponds to the reciprocal of resistance.
  • 2Convert 20 mA to 0.020 A and divide 6.0 V by current to obtain 300 ohms.
  • 2Use 9.0/300 to predict 0.030 A, or 30 mA.
Resistance is 300 ohms and the predicted current is 30 mA in the labelled positive direction. The second point preserves the linear 50 mA-per-volt conductance trend.
Sia tip — Convert prefixes before division and interpret the answer against the reference arrow.
Glossary

Key terms

Current reference
A current reference is the arrow chosen as positive for a branch calculation.
Ohmic component
An ohmic component has a linear current-voltage relation over the stated range.
Meter loading
Meter loading is the change in a circuit quantity caused by the instrument's finite resistance.
FAQ

Voltage, Current and Resistance FAQ

What does negative current mean?

It means the physical current flows opposite the chosen reference arrow; it does not make the solution invalid. Keep the negative value through the algebra, then report the real direction clearly in the final sentence.

Why is a voltmeter connected in parallel?

A voltage is a difference between two terminals, so the instrument must compare those same points while drawing little current. Its high input resistance limits the loading change imposed on the circuit.

Why convert milliamps first?

Base units keep voltage, current and resistance dimensionally consistent and prevent thousand-fold errors. Write the conversion explicitly, retain full precision during calculation and restore the requested prefix only at the end.

How should I record a meter reading?

Record the instrument mode, range, probe or lead positions, measured value and expected value. That context lets another person reproduce the observation and decide whether loading, polarity or a connection explains any disagreement.

What shows that a resistor is ohmic?

Several current-voltage points should follow an approximately straight line through the origin over the stated operating range. A changing slope indicates that one constant resistance does not describe the complete behaviour.

How can I diagnose an unexpected zero?

Check whether the measured nodes are genuinely at equal potential, whether an open path prevents current, and whether the meter mode and range match the quantity. Change one test condition at a time.

What is a useful direction check?

For a positive resistor, increasing applied voltage while conditions remain unchanged should increase current in the same reference direction. A prediction that moves oppositely needs its polarity, sign or model reviewed.

Why use several operating points?

One voltage-current pair gives one resistance estimate, but several points reveal whether the slope stays constant. Plotting them distinguishes linear behaviour from temperature, bias or device nonlinearity across the tested range.

What belongs in the final sentence?

State the magnitude with units, the actual direction relative to the reference and whether the result supports the assumed component model. This interpretation keeps a correct calculation tied to the physical circuit and exposes a sign that was never explained.

Study strategy

Exam move

Draw the reference arrow and polarity before every calculation. Drill base-unit conversions, then solve paired voltage-current problems and predict the direction before using a calculator. In laboratory preparation, identify the expected range and meter placement on the diagram. Finish each answer with the physical direction, magnitude and one unit check.

Working through Voltage, Current and Resistance in ELEC1130? Sia is AskSia’s AI Electrical Engineering tutor — ask any ELEC1130 Voltage, Current and Resistance question and get a clear, step-by-step explanation grounded in how ELEC1130 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 8 of your subjects at University of Leeds, plus 1,000+ more Bibles across the AskSia library.
Sia - your ELEC1130 tutor, unlimited, worked the way the exam marks it
The full 3-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial