RF Simulation, Measurement and Calibration is about trusting a result. A simulator solves the circuit equations it is given, and an instrument reports the quantity it was set up to measure, so both only describe the stated stimulus, operating point, bandwidth and reference plane.

The chapter starts with the device model: bias, transconductance, output conductance and voltage headroom must be right before any RF analysis means anything.

It then matches each design question to an analysis: DC and S-parameter solutions for bias and small-signal response, transient runs for startup and clipping, harmonic balance or shooting methods for periodic large-signal behaviour, periodic noise for mixers and oscillators, and envelope methods for long modulated waveforms.

On the measurement side, a vector network analyser records complex wave ratios, S11 and S21, whose log-magnitude display converts directly into reflected power and return loss, while a spectrum analyser shows power against frequency and needs its resolution bandwidth, attenuation and detector chosen deliberately.

Calibration removes systematic error: SOLT uses known short, open, load and thru standards, and TRL builds its standards in the device medium with a line whose extra phase must stay well away from 0 and 180 degrees. The chapter finishes with the receiver and transmitter tests that a radio must pass, from gain and noise figure to EVM, LO leakage and emission limits.

In this chapter

What this chapter covers

  • 01

    Device models, bias and voltage headroom before RF analysis

  • 02

    Choosing DC, transient, harmonic balance, periodic noise or envelope analysis

  • 03

    S-parameters, reflection coefficient and return loss

  • 04

    Spectrum analyser settings and analyser-generated distortion

  • 05

    SOLT and TRL calibration and on-wafer probing

  • 06

    Receiver tests: gain, linearity, noise figure, matching and I/Q balance

  • 07

    Transmitter tests: output power, OIP3, EVM, LO leakage and emissions

Worked example · free

Find the usable band of a TRL line standard

Q [4 marks]. A TRL kit uses a line 4 mm longer than its thru, with a phase velocity of 1.5 x 10^8 m/s. Using a single-line window of 20 to 160 degrees, find the phase difference per GHz and the frequency range over which the line can be used.
Phase difference between a TRL line standard 4 mm longer than the thru, with 1.5e8 m/s phase velocity, rises 9.6 degrees per GHz; it stays inside the 20 to 160 Phase difference between a TRL line standard 4 mm longer than the thru, with 1.5e8 m/s phase velocity, rises 9.6 degrees per GHz; it stays inside the 20 to 160 degree window only from 2.08 to 16.67 GHz.2.08 GHz16.67 GHz20°160°usable bandfrequency (GHz)020line minus thru phase
Phase difference between a TRL line standard 4 mm longer than the thru, with 1.5e8 m/s phase velocity, rises 9.6 degrees per GHz; it stays inside the 20 to 160 degree window only from 2.08 to 16.67 GHz.
  • 1Phase difference = 360 x f x 0.004 / (1.5 x 10^8), which is 9.6 degrees per GHz. The marks shown are an original practice allocation, not a University of Leeds marking scheme.
  • 1Lower edge: 20 / 9.6 = 2.08 GHz.
  • 1Upper edge: 160 / 9.6 = 16.67 GHz.
  • 1Outside 2.08 to 16.67 GHz the line and thru are too close in phase, so a second line length is needed to extend coverage.
The line adds 9.6 degrees per GHz and is usable from 2.08 to 16.67 GHz; multiline TRL extends the band. These marks are not an official university marking scheme.
Sia tip — Check the phase difference at both band edges before choosing a TRL line; near 0 or 180 degrees the calibration becomes ill-conditioned.
Glossary

Key terms

Harmonic balance
A frequency-domain solver that finds the periodic steady state of a nonlinear circuit with its harmonics.
Return loss
The ratio of incident to reflected power at a port, the negative of S11 in dB.
Resolution bandwidth
The analyser filter width that sets frequency selectivity and the noise admitted per point.
Reference plane
The boundary at which reported waves, powers and S-parameters are defined.
FAQ

RF Simulation, Measurement and Calibration FAQ

What does S11 = -10 dB mean in power terms?

The log-magnitude display shows 20 log10 of the reflection coefficient, so -10 dB means a magnitude of 0.316. Squaring gives 0.10, so 10% of the incident power reflects and about 90% enters the port. The return loss is the positive 10 dB.

Why can a linear noise simulation be wrong for a mixer?

A mixer is driven by a large LO and switches periodically, which translates noise from several sidebands into the output band. A DC-biased linear noise analysis misses that folding. Solve the periodic operating state first with harmonic balance or shooting, then run periodic noise and check its convergence.

How do I know whether the analyser created the IM3 product I see?

Raise the analyser input attenuation by 10 dB while keeping the device drive fixed. A product generated in the device stays roughly constant on the calibrated display, while one generated inside the analyser mixer falls by about 20 dB in the cubic region.

Why do simulation and measurement disagree?

First compare like with like: the same bias, temperature, frequency grid, port definitions and reference planes. A fixture between the measured planes, missing parasitics, model limits or calibration error are then the usual causes, and each needs a check that distinguishes it.

Study strategy

Exam move

Revise this chapter as a set of decisions you can justify in one sentence each. For simulation, make a two-column list of design questions and the analysis that answers them, and add the setting that must converge, such as time step for transient or the number of harmonics for harmonic balance.

For network analysis, practise converting S11 and S21 log-magnitude readings into reflection magnitude, reflected and transmitted power, return loss and VSWR, since a past paper opens with exactly that conversion for a power divider. For spectrum analysis, explain how resolution bandwidth changes the displayed noise but not a resolved tone, and how input attenuation exposes analyser-generated distortion.

For calibration, work one TRL line-length problem and say what goes wrong near 180 degrees. Then connect the chapter to the laboratories: for each of the five labs, list the analysis used, the settings to record and the hand calculation that checks it, because the report rubric awards half its marks to calculations, CAD methods, results and analysis.

Finally, rehearse a short paragraph that explains a mismatch between simulation and measurement using a controlled comparison, the structure the outline recommends for the report discussion.

Working through RF Simulation, Measurement and Calibration in ELEC5333M? Sia is AskSia’s AI Electrical Engineering tutor — ask any ELEC5333M RF Simulation, Measurement and Calibration question and get a clear, step-by-step explanation grounded in how ELEC5333M is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 8 of your subjects at University of Leeds, plus 1,000+ more Bibles across the AskSia library.
Sia - your ELEC5333M tutor, unlimited, worked the way the exam marks it
The full 3-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works
ELEC5333M · Wireless Communications Systems Design - independent study guide on the AskSia Library. More University of Leeds subjects · Microeconomics across all universities