Measurement, Pipetting and Solutions

Measurement, Pipetting and Solutions connects instrument range, physical technique and concentration arithmetic. The smallest suitable micropipette generally gives the strongest control over a target volume. Aspiration begins from the first stop, while the second stop is used at the end of dispensing to expel residual liquid. Smooth plunger movement, correct tip immersion and bubble checks protect precision.

Solution preparation then preserves solute amount while changing total volume, so final volume rather than diluent volume belongs in the dilution relation. Water mass checks help distinguish systematic bias from variable delivery.

In this chapter

What this chapter covers

  • 01

    Pipette range selection

  • 02

    First and second stops

  • 03

    Aspiration errors

  • 04

    Water mass checks

  • 05

    Weight per volume solutions

  • 06

    Dilution calculations

Worked example · free

Prepare a five-fold dilution

Q [4 marks]. Prepare 25 mL at 0.16 mg/mL from a 0.80 mg/mL stock.
The sequence distinguishes the first stop used to aspirate the set volume from the second stop used only at the end of dispensing, preventing systematic over-deThe sequence distinguishes the first stop used to aspirate the set volume from the second stop used only at the end of dispensing, preventing systematic over-delivery.set rangefit tipfirst stopaspiratefirst stopto dispensesecond stopblow outpressing to the second stop before aspiration draws more than the set volume
The sequence distinguishes the first stop used to aspirate the set volume from the second stop used only at the end of dispensing, preventing systematic over-delivery.
  • 1Calculate a dilution factor of five.
  • 2Use 5 mL of stock and make the total volume to 25 mL.
  • 1Check that solute amount is unchanged before and after dilution.
Transfer 5 mL stock and add diluent to a final volume of 25 mL. This original revision allocation for Measurement, Pipetting and Solutions is not a published university marking scheme. This original revision allocation for Measurement, Pipetting and Solutions is not a published university marking scheme.
Sia tip — Never substitute the volume of diluent for final volume.
Glossary

Key terms

Pipette range
Pipette range is the interval of volumes the instrument is designed to transfer.
Dilution factor
Dilution factor is final volume divided by the volume of original sample used.
Precision
Precision describes agreement among repeated measurements.
FAQ

Measurement, Pipetting and Solutions FAQ

Why not always use the largest pipette?

A target near the low end of a large instrument can carry greater relative error. Choose the smallest pipette whose stated range comfortably includes the required volume.

What happens if I aspirate from the second stop?

Releasing the plunger from the second stop draws more than the set volume. The second stop is reserved for blowing out residual liquid during delivery.

How can water mass check delivery?

Near room temperature, one millilitre of water has a mass close to one gram. Converting the target volume to millilitres gives an approximate expected mass.

Study strategy

Exam move

Draw the pipette sequence from memory and label the first stop at aspiration and the second stop at final delivery. Practise selecting among overlapping pipette ranges, then predict whether common faults cause too much, too little, variable or contaminated transfer. For solution questions, write initial concentration, initial volume, final concentration and final volume before rearranging the equation.

Confirm that the amount of solute is conserved. Use water-mass examples to separate accuracy from precision and keep microlitre-to-millilitre conversion visible. Finish each calculation by naming whether the result describes stock, diluted tube or final solution, because many distractors use a correct number from the wrong sample stage. Rehearse pipetting as a physical sequence rather than a slogan.

Fit the correct tip, set a volume inside the instrument range, depress to the first stop before entering liquid, immerse only as far as needed, release smoothly and pause for aspiration. Deliver against the receiving vessel, press through the first stop to the second stop and withdraw while the plunger remains depressed. For each deliberate error, predict direction and variability.

Releasing too quickly can introduce bubbles and inconsistent aspiration; using the second stop during uptake draws excess liquid; failing to blow out can leave part of the intended volume behind. Changing tips protects sample identity when carry-over matters. Build volume-choice drills with overlapping pipettes.

Select the instrument that contains the target volume and measures it most appropriately, then check that the displayed digits are interpreted for that model. Keep microlitres and millilitres visible through the calculation instead of converting mentally. When checking performance with water, compare repeated masses with the expected mass for the delivered volume.

A tight cluster away from the expected value indicates repeatability with bias; a wide cluster indicates poor precision. Do not call an operation accurate merely because one reading happens to land near the target. Look at the pattern and the calibration conditions. For solutions, draw two labelled boxes for stock and final mixture. Place C1 and V1 in the stock box and C2 and V2 in the final box before using C1V1 = C2V2.

Explain the conservation idea: dilution changes total volume and concentration but not the amount of solute transferred. After solving V1, calculate diluent as final volume minus stock volume and reject any negative or impossible result. For mass concentration, show mass divided by final solution volume, not solvent volume alone. For molarity, convert grams per litre with molar mass so that units cancel to moles per litre.

End with a direction check: a dilution should have lower concentration than its stock, and a larger final volume at fixed concentration requires more solute. For a mixed drill, choose a pipette for the stock aliquot, calculate the dilution, predict the mass of an equivalent water delivery and explain how one handling fault would change the result.

This joins instrument choice, technique, units and calculation in one auditable chain.

Working through Measurement, Pipetting and Solutions in BIOL10401? Sia is AskSia’s AI Biology tutor — ask any BIOL10401 Measurement, Pipetting and Solutions question and get a clear, step-by-step explanation grounded in how BIOL10401 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 41 of your subjects at The University of Manchester, plus 1,000+ more Bibles across the AskSia library.
Sia - your BIOL10401 tutor, unlimited, worked the way the exam marks it
The full 2-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works