BENG0003 Chap.8 Recycle, Bypass and Multiple-Unit Balances
Recycle, Bypass and Multiple-Unit Balances
Recycle, Bypass and Multiple-Unit Balances extends the Week 10 mass-balance method to the Week 13 flowsheets where streams loop back, skip a unit or pass through several units in series.
It defines recycle as material returned from a later point for further processing, bypass as part of the feed skipping a unit and rejoining the product, and purge as a continuous bleed from a recycle that stops an unwanted component accumulating. It lists the reasons a plant adds each stream, from higher overall conversion and catalyst or cell recycle to reflux and diluting a thick slurry.
The core skill is choosing system boundaries: around the whole process, around a mixing point, around a single unit or around a splitting point. The chapter explains why the overall boundary and a unit inside the loop say nothing about the recycle, while a mixer or separator boundary crossed by it does. Degrees of freedom are handled by counting unknowns against independent equations before any algebra.
Worked examples solve an evaporator bypass, a filtrate recycle, a centrifuge and dryer in series, and a purge on a water loop, and every balance closes with a check.
What this chapter covers
- 01
Recycle, bypass and purge streams defined
- 02
Why plants use recycle and cell recycle
- 03
Bypass around an evaporator with a mixing point
- 04
Choosing overall, mixer, unit and splitter boundaries
- 05
Which boundaries reveal the recycle flow
- 06
Counting unknowns against independent equations
- 07
Units in series solved one boundary at a time
- 08
Sizing a purge from the impurity balance
Worked example · free
Size the bypass around a sugar evaporator
- 2Overall boundary, sugar: 0.10 x 1,200 = 0.25P, so P = 480 kg/h. Overall total: 1,200 = P + W, so the water evaporated is W = 720 kg/h.
- 2Evaporator boundary, sugar: 0.10E = 0.40 x concentrate, so concentrate = 0.25E and the water removed is 0.75E = 720 kg/h, giving E = 960 kg/h through the evaporator.
- 1Splitting point: bypass B = 1,200 - 960 = 240 kg/h, so the bypassed fraction is 240/1,200 = 0.20.
- 1Mixing point check: 240 kg/h concentrate at 40% plus 240 kg/h bypass at 10% gives 480 kg/h carrying 96 + 24 = 120 kg/h sugar, which is 25%.
Key terms
- Bypass stream
- Part of a feed that is split off before a unit, skips it, and rejoins the product downstream.
- Purge stream
- A small continuous withdrawal from a recycle loop that keeps an unwanted component below a tolerable level.
- Recycle ratio
- Flow returned in the recycle divided by a chosen product or outlet flow, used to describe how much material circulates.
- Degrees of freedom
- Number of unknowns minus the number of independent equations available; zero means the balance can be solved.
- Splitting point
- Junction where one stream divides into two or more with identical composition, such as a recycle and a purge.
Recycle, Bypass and Multiple-Unit Balances FAQ
What is the difference between recycle and bypass in mass balances?
Recycle takes material that has already left a unit and returns it upstream, so it forms a closed loop. Bypass divides the fresh feed before a unit so that part skips it and rejoins further on, so no loop forms. On a flowsheet, follow the arrow: a stream running backwards is a recycle, one running forwards around a unit is a bypass.
Why can't the overall balance give the recycle flow?
The recycle starts and ends inside the overall boundary, so it never crosses that line and never appears in the overall equations. To find it you need a boundary that it does cross, usually around the mixer where fresh feed and recycle meet, or around the separator or splitter where it is drawn off.
Why do processes with recycle need a purge?
Any component that enters with the fresh feed but cannot leave with the product will circulate and build up in the loop. A purge removes part of the recycle continuously, so at steady state the inert leaves as fast as it enters. Its size follows from one balance on that component around the whole plant.
How many equations can I write for one system boundary?
With n components you can write n independent balances: either one balance per component, or a total balance plus n minus one component balances. Writing all n plus the total adds no new information, and neither does the rule that mass fractions sum to one once every component balance is already used.
How do I start a multiple-unit mass balance problem?
Draw and label every stream, list the basis and assumptions such as steady state and no reaction, then count unknowns and independent equations for each possible boundary. Open the boundary where the counts match, often the overall one, and carry each solved flow into the next unit. End by checking that every unit closes.
Exam move
Begin by redrawing the lecture flowsheets for recycle, bypass and purge from memory, adding dashed boundaries around the whole process, the mixer, each unit and the splitter. For each boundary, list which streams cross it; this alone shows why only some boundaries reveal a recycle.
Then work the distillation reflux exercise from the lecture notes, followed by your own variations with a bypass and a purge, always writing the unknown count and equation count next to each boundary before any algebra. Use the steps taught for single-unit balances in the same order: flowsheet, basis, assumptions, balances, table and check.
Close every problem with a check on a boundary you did not use to solve it, since a balance that closes there is strong evidence the streams are right. Finally, time yourself on one two-unit series problem.