University College London · FACULTY OF ENVIRONMENTAL SCIENCE

BENV0090 Chap.3 Transport, Buildings and Industry Demand

- one subject, every graph, every model, every mark
6 Chapters3-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 3 of 10 · BENV0090

Transport, Buildings and Industry Demand

Transport, Buildings and Industry Demand reads the system from the end where people use energy. It distinguishes the service people want from the final and primary energy needed to supply it, and compares the inertia of vehicle fleets, building stocks and industrial plant. A clinic shows why an efficiency gain is not automatically an emissions cut: a heat pump's benefit depends on the carbon intensity of the grid.

The chapter also covers frictions and rebound in demand-side measures and prepares the demand-supply scenario tutorial, in which the target is zero CO2 relative to 1990 by 2050. Practice items compare electric and petrol cars per kilometre on clean and dirty grids, and test whether falling industrial output is a real demand-side success or production moved abroad.

In this chapter

What this chapter covers

  • 01

    Energy services and end use

  • 02

    Final versus primary energy

  • 03

    Transport fleet turnover

  • 04

    Building retrofit and heating

  • 05

    Industrial emissions and trade

  • 06

    Rebound and adoption frictions

Worked example · free

Find the grid intensity at which a heat pump pays off

Q [5 marks]. A home needs 10 MWh of heat a year. A gas boiler is 90% efficient and gas emits 0.18 t CO2 per MWh. A heat pump has a coefficient of performance of 3. Find the boiler's emissions and the grid intensity at which the heat pump breaks even. The marks shown are an original study allocation, not an official UCL marking scheme.
Both options deliver 10 MWh of heat.Both options deliver 10 MWh of heat. The boiler burns 11.1 MWh of gas; the heat pump with a coefficient of performance of 3 draws 3.3 MWh of electricity, which needs 6.7 MWh of primary fuel if generated at 50% efficiency.Gas boilerHeat 10.0Final gas 11.1Primary 11.1Heat pumpHeat 10.0Final power 3.3Primary 6.7MWh of energy
Both options deliver 10 MWh of heat. The boiler burns 11.1 MWh of gas; the heat pump with a coefficient of performance of 3 draws 3.3 MWh of electricity, which needs 6.7 MWh of primary fuel if generated at 50% efficiency.
  • 2Boiler gas use = 10 / 0.90 = 11.1 MWh; emissions = 11.1 x 0.18 = 2.0 t.
  • 1Heat pump electricity = 10 / 3 = 3.33 MWh.
  • 2Break-even intensity = 2.0 / 3.33 = 0.60 t per MWh of electricity.
On any grid cleaner than 0.60 t per MWh the heat pump emits less than the boiler; at 0.15 t it emits 0.5 t, a cut of three quarters. The marks are an original practice allocation.
Sia tip — Write the carbon intensity of the energy carrier beside every efficiency claim, then compare emissions, not energy.
Glossary

Key terms

Coefficient of performance
Heat delivered by a heat pump per unit of electricity it uses.
Rebound effect
Extra energy use that follows when efficiency makes an energy service cheaper.
Energy service
The useful outcome people want from energy, such as warmth, light or a journey.
Retrofit
Upgrading an existing building's fabric or heating system to cut its energy use or emissions.
FAQ

Transport, Buildings and Industry Demand FAQ

Why can demand measures be cheaper than new supply?

A unit of energy not used needs no generation, no network capacity and no imported fuel. That is why the demand-supply scenario often reaches deep targets at lower cost once demand settings are unlocked, provided the assumed behaviour is realistic.

Does electrification always cut emissions?

No. Electric cars and heat pumps use far less final energy, but their emissions depend on how the electricity is generated. On a coal-heavy grid the saving can vanish, so state the grid intensity behind any claim.

Why does industry need separate treatment?

Industry combines high-temperature heat, chemical process emissions and globally traded products. A country can cut industrial emissions by importing the same goods, so a demand-side analysis asks whether material use per unit of service actually fell.

What does the demand-supply scenario change from the previous week?

It reopens the supply-side model and unlocks demand settings, so groups can change how much energy transport, buildings and industry use as well as how it is supplied. The target tightens to zero CO2 relative to 1990 by 2050, and the group reaching it at the lowest cost with realistic outputs wins the prize.

Why is building retrofit so central to demand reduction?

Most buildings standing in 2050 already exist, so new standards alone will not change the stock in time. Insulating fabric and replacing heating systems in existing homes is the main lever, but upfront costs, disruption and doubts about installers slow adoption, which is why policy design matters as much as technology.

Study strategy

Assessment move

Practise moving between service, final and primary energy until it is automatic: write the chain for heating, a car journey and a steel product. For each sector, note the replacement cycle of its main assets, because it limits how fast demand can change. Rework the heat pump clinic with your own country's published grid intensity and decide whether the switch helps today.

Before the demand-supply tutorial, list the demand levers in the model and estimate which ones real households and firms could adopt by 2050; the presentation is stronger when it explains why a lever is plausible as well as what it does to the totals.

For each sector, keep a short note of the biggest frictions that slow change: upfront cost and hassle for homes, charging access and second-hand prices for vehicles, and international competition for industry. The behaviour-change review cited in later chapters gives evidence on several of these.

When you write about a demand target in the essay, separate how much energy a measure could save on paper from how much it is likely to save after rebound and partial adoption, and say which data would let you measure the difference.

A+Everything unlocked
Unlocks this Bible + all 32 of your subjects at University College London, plus 1,000+ more Bibles across the AskSia library.
Sia - your BENV0090 tutor, unlimited, worked the way the exam marks it
The full 3-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works