Hong Kong Baptist University · FACULTY OF PHYSICS

PHYS7470 Chap.4 Activity Data, Factors and CO2e

- one subject, every graph, every model, every mark
6 Chapters4-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 4 of 8 · PHYS7470

Activity Data, Factors and CO2e

Quantification is an evidence chain

A credible inventory preserves the path from source records to activity data, matched emission factors, gas masses, global warming potential and CO2e. The calculation is reproducible only when each transition is visible. A final corporate total cannot reveal whether one source used the wrong denominator, mixed grams with kilograms or treated purchases as releases.

Source-level worksheets retain the original quantity, unit, factor, factor version, gas, GWP basis, assumptions and converted result before any roll-up occurs.

Select records closest to the activity

Metered electricity, fuel logs, travel distance and material quantities can all serve as activity data, but the closest available record is not always consumption.

Stocked material requires a balance because purchases increase inventory. Opening stock plus inflows must be reconciled with closing stock, transfers, recovery and disposal before a use or release estimate is accepted. When a flow is unknown, it is disclosed as an assumption rather than silently entered as zero.

That distinction keeps uncertainty attached to the source that created it.

Factors need a matching basis

Emission factors carry a denominator, geography, time period and sometimes a technology or supplier. The denominator must cancel the activity unit, and the factor basis should fit the source as closely as the available evidence permits.

Recent factors improve relevance, while consistent factors protect comparison through time.

If the coefficient changes between periods, the report explains whether the historical series was recalculated so a factor update is not mistaken for an operational improvement.

Calculate by gas and round after checking

A gas-specific factor produces a gas mass that must be converted to a common mass unit and multiplied by the appropriate GWP. A factor already stated in CO2e does not receive GWP again.

Working gas by gas makes gram-to-kilogram conversions and high-GWP contributions visible. Retain full precision until the source result has been reviewed, then choose a reporting precision for the roll-up. Late rounding protects small contributions that can become material after conversion.

In this chapter

What this chapter covers

  • 01

    Source records

  • 02

    Factor selection

  • 03

    Stock balances

  • 04

    Gas-specific factors

  • 05

    GWP conversion

  • 06

    Inventory roll-up

Worked example · free

Calculate a multi-gas source

Q [8 marks]. Convert fuel activity with CO2, CH4 and N2O factors. This practice mark allocation helps sequence unit conversion, gas conversion and addition; it is not an official assessment scheme.
The inventory narrows through controlled choices.The inventory narrows through controlled choices. Records become comparable emissions only after each activity is paired with a factor whose denominator matches the recorded unit.records and activity datamatched factorsCO2e roll-up
The inventory narrows through controlled choices. Records become comparable emissions only after each activity is paired with a factor whose denominator matches the recorded unit.
  • 4Calculate each gas mass with its own units.
  • 4Apply GWP and sum CO2e.
The model keeps gram and kilogram conversions visible before adding CO2e contributions.
Sia tip — Read the factor numerator before adding GWP.
Glossary

Key terms

Stock Balance
Opening stock plus inflows minus closing stock and documented outflows.
Factor Basis
The geography, period, technology and unit underlying an emission factor.
Inventory Roll-up
The controlled addition of checked source-level CO2e results into category and corporate totals, performed only after activity units, factor bases, gas conversions, assumptions and rounding have been reviewed, reconciled and retained for independent recalculation.
FAQ

Activity Data, Factors and CO2e FAQ

Why not treat purchases as emissions?

Purchases can increase inventory without proving consumption or release. Opening stock, closing stock, transfers, recovery and disposal must be reconciled so the estimated activity reflects material that actually left the balance. Unknown flows remain assumptions beside the estimate rather than unexplained zeroes. This distinction prevents stored material from being assigned an atmospheric impact prematurely.

When should results be rounded?

Keep sufficient precision through mass conversion and GWP multiplication, then round at the source reporting stage. Early rounding can distort small methane or nitrous-oxide quantities after their warming conversion. Preserve the unrounded value in the worksheet even when the report displays fewer decimals.

What belongs in a calculation sheet?

Record activity, unit, factor, factor unit, factor version, gas, GWP basis, assumptions and final CO2e for every source. Preserve the original record reference so another auditor can reproduce it. Category subtotals should reconcile with the source rows before they enter the corporate roll-up.

Study strategy

Exam move

Build one row per source and audit the units from left to right. For stock-based estimates, list every inflow and outflow before calculating. For multi-gas factors, convert each gas mass separately, apply GWP only where needed and delay rounding. Recalculate at least one material source independently, then trace its value from the original record through the source sheet to the final inventory roll-up.

Add fields for factor geography, year, technology or supplier and version so a coefficient change remains distinguishable from lower activity. Work one example with grams of methane and nitrous oxide beside kilograms of carbon dioxide; convert the masses before adding CO2e. Work another example whose factor numerator already states CO2e and explain why a second GWP multiplication would be wrong.

When a stock flow is missing, write the assumption on the row rather than entering an unexplained zero. Before accepting the corporate total, sum the source rows independently and compare category subtotals with the roll-up. The aim is not only a correct number but a trail from original record to reported tonnes that a second analyst can reproduce.

Working through Activity Data, Factors and CO2e in PHYS7470? Sia is AskSia’s AI Physics tutor — ask any PHYS7470 Activity Data, Factors and CO2e question and get a clear, step-by-step explanation grounded in how PHYS7470 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 16 of your subjects at Hong Kong Baptist University, plus 1,000+ more Bibles across the AskSia library.
Sia - your PHYS7470 tutor, unlimited, worked the way the exam marks it
The full 4-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works