The University of Hong Kong · FACULTY OF ENVIRONMENTAL SCIENCE

CCST9016 Chap.6 Solar Cells, Modules and PV Performance

- one subject, every graph, every model, every mark
7 Chapters4-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 6 of 7 · CCST9016

Solar Cells, Modules and PV Performance

A photovoltaic cell makes electrical output directly

A photovoltaic cell absorbs photons in a semiconductor and creates mobile charge carriers. A built-in electric field at a junction separates those carriers, allowing current to flow through an external circuit. The explanation requires both absorption and selective charge movement.

Saying that sunlight simply becomes electricity skips the mechanism that produces voltage and determines why material properties, recombination and contacts matter.

The current-voltage curve contains several different quantities

Short-circuit current is measured when voltage is zero, so electrical power is zero at that endpoint. Open-circuit voltage is measured when current is zero, so power is also zero there.

The useful operating region lies between them. Multiplying current and voltage at each point produces a power curve with a maximum-power point. A controller seeks that point as irradiance and temperature change.

Reading the largest current or voltage alone does not identify maximum output.

Efficiency needs incident area and irradiance

Photovoltaic efficiency is maximum electrical power divided by solar power incident on the active or specified module area. If irradiance is G and area is A, incident power is GA. Maximum output is Vmpp times Impp. The area convention and test conditions matter.

A cell efficiency measured under standard laboratory conditions cannot be treated as annual system yield without accounting for weather, temperature, orientation and system losses.

Cells form modules and arrays

Series connection raises voltage while current is limited by the weakest series path. Parallel connection raises current while voltage remains associated with the branch operating point.

Cells are packaged into modules for protection and electrical connection, and modules form strings and arrays. Bypass diodes can reduce damage and loss when part of a module is shaded, but they do not make shade irrelevant. Mismatch changes the shape of the combined current-voltage curve.

Irradiance and temperature change performance differently

Higher irradiance generally raises current and available power.

Higher cell temperature commonly reduces voltage and therefore maximum power, even though current may change slightly. Module temperature can exceed air temperature, so a hot sunny installation can deliver less than a nameplate calculation based only on irradiance.

Dust, cable resistance, inverter conversion, mismatch and degradation add further losses between direct-current module output and exported alternating-current energy.

Power rating is not energy yield

A rated kilowatt is capacity under specified conditions.

Energy yield accumulates power over time and depends on the irradiance profile, orientation, shading, temperature, availability and balance-of-system performance. Capacity factor or specific yield can summarise a period, but they answer different questions. For design, state whether the target is peak power, annual energy, reliable supply at a particular time or avoided grid purchase.

The preferred orientation or storage choice can change with that target.

In this chapter

What this chapter covers

  • 01

    Photon absorption and charge separation

  • 02

    Junction field, current and voltage

  • 03

    Short circuit and open circuit endpoints

  • 04

    Maximum-power point on the current-voltage curve

  • 05

    PV efficiency from incident and electrical power

  • 06

    Series strings, parallel branches and mismatch

  • 07

    Temperature, shading and balance-of-system losses

Worked example · free

Calculate module efficiency at the maximum-power point

Q [10 marks]. AskSia-authored practice. A module of area 1.65 m2 operates at 31.0 V and 8.4 A at its maximum-power point under irradiance of 900 W/m2. Calculate maximum electrical power and module efficiency. If cell temperature later reduces maximum-power voltage by 7% while current remains unchanged, estimate the new power. The marks shown are an AskSia study allocation, not the University's marking scheme.
The blue current curve and orange power curve share the voltage axis.The blue current curve and orange power curve share the voltage axis. Power vanishes at both endpoints and peaks only where current and voltage remain nonzero. Maximum power lies between short circuit and open circuit maximum power short-circuit currentopen-circuit voltagepowervoltage
The blue current curve and orange power curve share the voltage axis. Power vanishes at both endpoints and peaks only where current and voltage remain nonzero.
  • 2Multiply maximum-power voltage and current to find electrical output.
  • 4Calculate incident solar power from irradiance and area, then efficiency.
  • 4Apply the voltage reduction and recompute output under the stated simplification.
Maximum electrical power is 31.0 x 8.4 = 260.4 W. Incident solar power is 900 x 1.65 = 1485 W, so efficiency is 260.4/1485 = 0.175, about 17.5%. After a 7% voltage reduction, maximum-power voltage is 31.0 x 0.93 = 28.83 V. With current held at 8.4 A, estimated power is 28.83 x 8.4 = about 242.2 W. This simplified estimate excludes any simultaneous current or curve-shape change.
Sia tip — Use maximum-power voltage and current together. Open-circuit voltage and short-circuit current never occur at the same operating point.
Glossary

Key terms

Photovoltaic Effect
Generation of voltage and current when absorbed light creates and separates charge carriers.
Semiconductor
A material whose controllable electrical properties enable junction-based devices.
Charge Carrier
A mobile electron or hole that contributes to electrical conduction.
Short-Circuit Current
Cell or module current measured when terminal voltage is zero.
Open-Circuit Voltage
Terminal voltage measured when external current is zero.
Maximum-Power Point
The current-voltage operating point producing the greatest electrical power.
Fill Factor
The ratio of maximum power to open-circuit voltage times short-circuit current.
Module String
Modules connected in series to raise operating voltage.
Bypass Diode
A device providing an alternate current path around a shaded or limited cell group.
Specific Yield
Energy generated over a period divided by installed rated power.
FAQ

Solar Cells, Modules and PV Performance FAQ

Why is power zero at both ends of an IV curve?

At short circuit, current is high but terminal voltage is zero. At open circuit, voltage is high but current is zero. Since power equals voltage multiplied by current, both endpoints produce zero output. Maximum power occurs at an intermediate operating point where both quantities have useful values.

Can I multiply open-circuit voltage by short-circuit current?

That product is a reference rectangle used in the fill-factor definition, not an achievable operating output. The two values are measured under mutually exclusive terminal conditions. Use voltage and current from the same point on the curve, especially the stated maximum-power point, when calculating delivered electrical power.

Why does partial shading affect more than the shaded area?

Series-connected cells carry a common current, so one shaded cell group can limit the string and distort its operating curve. Bypass diodes can route current around affected groups, reducing severe loss and heating, but they also remove part of the module voltage. Array layout and multiple power maxima then matter.

What is the difference between rated power and annual energy?

Rated power is measured under specified test conditions at one operating point. Annual energy integrates changing power across weather, orientation, temperature, shade, downtime and conversion losses. Two equal-rated systems can therefore have different yields. Compare the metric that matches the service and time horizon of the decision.

Study strategy

Assessment move

Sketch an IV curve and mark short circuit, open circuit and maximum power before solving any photovoltaic question. Write P = VI beside the curve and test the two endpoints, where power must be zero. For efficiency, create separate lines for incident power GA and electrical power VmppImpp; divide only after confirming area and irradiance describe the same module boundary.

Practise changes qualitatively before calculating: more irradiance mainly raises current, higher temperature commonly lowers voltage, and series mismatch limits current. Build a second diagram from cell to module, string, array, inverter and grid, noting where direct-current ratings become alternating-current delivery and where losses enter.

For energy-yield questions, draw a daily power profile and treat energy as area under it instead of multiplying nameplate power by all hours. Add one limitation to every estimate, such as shading, temperature, inverter clipping, downtime or degradation. Finish by explaining why open-circuit voltage multiplied by short-circuit current is not usable output.

If that explanation is clear, the rest of the chapter becomes an organised set of operating points rather than disconnected terms.

A+Everything unlocked
Unlocks this Bible + all 52 of your subjects at The University of Hong Kong, plus 1,000+ more Bibles across the AskSia library.
Sia - your CCST9016 tutor, unlimited, worked the way the exam marks it
The full 4-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works