The University of Hong Kong · FACULTY OF ENVIRONMENTAL SCIENCE

CCST9016 Chap.5 Solar Irradiance and Thermal Systems

- one subject, every graph, every model, every mark
7 Chapters4-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 5 of 7 · CCST9016

Solar Irradiance and Thermal Systems

Begin with radiation arriving at a surface

Solar irradiance is radiant power per unit area, commonly expressed in watts per square metre. It is not energy until multiplied by area and time, and it is not automatically the useful output of a collector. The amount intercepted depends on atmospheric conditions, location, time and surface orientation.

Beam radiation arriving normal to a surface has a larger projected contribution than the same beam arriving obliquely. With a consistently defined incidence angle, the direct component on the surface follows a cosine projection.

Geometry is a definition problem before it is arithmetic

Angles can be measured from the surface normal, horizontal plane or another reference.

A cosine expression is correct only for its stated definition. If the angle from the normal is zero, the beam is perpendicular and the projection factor is one. At ninety degrees, the beam is parallel to the surface and the direct projection is zero.

Sketching the normal and incident ray is the quickest protection against using the complementary angle or producing a physically reversed result.

A collector is an energy balance

A solar thermal collector absorbs part of the incident radiation and transfers part of that absorbed energy to a working fluid. Reflection, imperfect absorption and heat loss to the surroundings reduce useful output.

Useful thermal power can be framed as mass flow rate multiplied by specific heat capacity and temperature rise. Collector efficiency compares that useful thermal power with solar power incident on the collector aperture.

The fluid equation and solar equation should agree when measured over the same steady period and boundary.

Temperature raises value and loss together

Higher delivery temperature can make heat more useful for some services, but it generally increases heat loss to cooler surroundings. A collector suitable for domestic water heating may not be appropriate for a high-temperature industrial process.

Selective surfaces, glazing and insulation can reduce losses, while concentration increases flux but depends strongly on direct radiation and tracking. Technology choice therefore starts with required temperature and demand timing rather than the word solar.

Storage connects collection to demand

Sunlight and heat demand rarely align perfectly.

Thermal storage shifts energy across time, but storage volume, insulation, temperature range and loss rate constrain its value. A water store holds sensible heat proportional to mass, heat capacity and temperature change. The calculation describes stored thermal energy, not necessarily usable energy; a minimum delivery temperature can leave part of the store unavailable.

Controls, pumps and backup supply complete the system.

Evaluate a complete solar-thermal service

A useful design estimate combines irradiance, orientation, area, collector performance and operating time, then checks whether demand can accept the heat. Annual output requires changing weather and losses rather than one noon rating.

A system can have a well-performing collector but poor utilisation because the store is full or demand is absent. Report solar fraction, useful heat or displaced fuel with a clear baseline, and separate measured performance from a theoretical optical estimate.

In this chapter

What this chapter covers

  • 01

    Irradiance as solar power per unit area

  • 02

    Incidence angle and cosine projection

  • 03

    Collector absorption and thermal loss

  • 04

    Fluid heat gain from mass flow and temperature rise

  • 05

    Collector efficiency at a stated boundary

  • 06

    Required temperature and collector choice

  • 07

    Thermal storage, demand timing and solar fraction

Worked example · free

Connect solar geometry to useful heat

Q [9 marks]. AskSia-authored practice. Beam irradiance normal to the sun is 820 W/m2. A 6.0 m2 flat collector has an incidence angle of 35 degrees from its normal and converts 52% of incident power to useful heat. Estimate useful thermal power and energy delivered during 2.5 hours at these constant conditions. The marks shown are an AskSia study allocation, not the University's marking scheme.
The orange rays carry equal spacing before meeting each surface.The orange rays carry equal spacing before meeting each surface. Oblique incidence spreads that input across a wider footprint, reducing direct-beam irradiance per square metre. The same beam spreads across more surface when incidence becomes oblique larger projected area θ smaller projected area Ė = Ėₙ cos θ
The orange rays carry equal spacing before meeting each surface. Oblique incidence spreads that input across a wider footprint, reducing direct-beam irradiance per square metre.
  • 3Project beam irradiance onto the collector using the stated angle definition.
  • 3Multiply by area and collector efficiency to find useful thermal power.
  • 3Multiply by time to find energy and state the constant-condition assumption.
Projected irradiance is 820 cos 35 degrees = about 672 W/m2. Incident collector power is 672 x 6.0 = about 4.03 kW. Useful thermal power is 0.52 x 4.03 = about 2.10 kW. Over 2.5 hours, useful energy is 2.10 x 2.5 = about 5.24 kWh of heat. The estimate assumes beam irradiance, angle and efficiency remain constant and excludes diffuse radiation, shading, pump demand, storage loss and any limit from absent heat demand.
Sia tip — Sketch the collector normal. A zero-degree incidence angle must give the maximum projected beam before you trust the cosine.
Glossary

Key terms

Solar Irradiance
Solar radiant power incident on unit area at a specified moment.
Beam Radiation
Solar radiation arriving directly from the apparent solar disc.
Diffuse Radiation
Solar radiation reaching a surface after scattering in the atmosphere.
Incidence Angle
The angle between an incoming ray and the surface normal unless otherwise defined.
Collector Aperture
The effective area through which solar radiation enters a collector.
Flat Collector
A non-concentrating solar thermal device that absorbs radiation on a planar surface.
Selective Surface
A surface designed for strong solar absorption and reduced thermal emission.
Sensible Heat
Thermal energy stored through a temperature change without a phase change.
Solar Fraction
The fraction of a defined heat demand supplied by solar energy.
Stagnation Temperature
Collector temperature reached when absorbed solar power equals losses with no useful heat removal.
FAQ

Solar Irradiance and Thermal Systems FAQ

What is the difference between irradiance and irradiation?

Irradiance is power per unit area at an instant, usually W/m2. Irradiation is energy per unit area accumulated over a period, such as kWh/m2 per day. Multiplying constant irradiance by time gives irradiation. Real sunlight changes, so measured irradiation normally comes from integrating a varying irradiance profile.

Why does collector orientation matter?

A tilted surface presents a projected area to the direct beam. When the beam aligns with the surface normal, the projection is greatest. At an oblique angle, less beam power falls on each unit of collector area. Orientation also changes diffuse and reflected contributions, so the simple cosine covers only the direct component.

Does a hotter collector always provide more useful energy?

No. Higher temperature may improve the quality of the heat for a demanding service, but it also increases losses to the surroundings. Useful output depends on the balance between absorbed solar power, heat removal and loss. The correct operating temperature is tied to the service, not simply maximised.

Why can storage capacity fail to increase solar fraction?

A larger store helps only if it can receive surplus heat and later deliver it above the required temperature. Excessive losses, weak stratification, pump controls or a demand pattern outside the storage duration can erase the benefit. Evaluate usable temperature range and timing rather than quoting storage volume alone.

Study strategy

Assessment move

Draw the sun ray, collector plane and surface normal before any solar-geometry calculation. Write the angle definition in words, then test the limiting cases of zero and ninety degrees. Build every numerical solution in four layers: projected irradiance, incident power, useful thermal power and energy over time. Keep W/m2, m2, W and Wh visibly distinct.

For collector questions, pair the solar-side balance with the fluid-side expression based on mass flow, heat capacity and temperature rise; disagreement signals a boundary, unit or measurement issue. For storage, sketch collection and demand across time and label the usable temperature range.

Practise choosing a collector by first stating the service temperature, climate input and demand pattern, then evaluating optical gain, thermal loss, pumping and storage. End each estimate with omitted effects such as diffuse radiation, shading, changing weather, controls or unused heat. That sentence is not an apology; it defines what the number can support.

A final retrieval drill is to explain why maximum incident radiation, maximum collector efficiency and maximum useful annual energy need not occur at the same operating condition.

A+Everything unlocked
Unlocks this Bible + all 52 of your subjects at The University of Hong Kong, plus 1,000+ more Bibles across the AskSia library.
Sia - your CCST9016 tutor, unlimited, worked the way the exam marks it
The full 4-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works