EE509 Chap.6 Measuring Townsend Coefficients
Measuring Townsend Coefficients
Linearisation reveals the primary coefficient
The experiment varies electrode distance while holding field intensity fixed. Divider readings are converted to actual gap voltage and current is normalised by its initial value.
Taking the natural logarithm converts primary exponential growth into a straight line: the slope of ln(I/I0) against distance is alpha.
Region choice is part of the measurement
The initial linear region represents primary growth. Upward departure indicates secondary feedback and should not be included in the alpha fit.
Gamma is then estimated separately near the spark distance through the secondary current relationship. A complete report labels axes and units, marks instrument limits and explains why the selected points belong to one physical regime.
What this chapter covers
- 01
Voltage-divider conversion
- 02
Field consistency across distances
- 03
Current normalisation
- 04
Natural-log linearisation
- 05
Primary-region slope for alpha
- 06
Secondary-region estimate for gamma
- 07
Audit protocol: retain raw readings, document the divider conversion, verify constant field, normalise current consistently, fit only the physically identified primary interval, test endpoint sensitivity, estimate gamma separately in the secondary region, and archive exclusions, units and instrument limits so another reader can reproduce every inference
Worked example · free
Fit alpha from two primary points
- 2Find the vertical change.
- 2Find the distance change.
- 2Divide and state reciprocal units.
Key terms
- Normalised Current
- Measured current divided by a consistent initial current to remove the scale of the source.
- Linearisation
- A transformation that turns an exponential relationship into a straight line for parameter estimation.
- Primary Region
- The near-linear log-current interval dominated by primary avalanche growth.
- Instrument Limit
- A measurement boundary created by apparatus range or sensitivity rather than by the gas.
Measuring Townsend Coefficients FAQ
Why plot the natural logarithm of current ratio?
Primary Townsend growth is exponential, so taking the natural logarithm produces a line whose slope is alpha. A raw current plot obscures that slope and makes secondary curvature harder to separate from primary growth.
Why are the final high-current points excluded from the alpha fit?
They contain secondary cathode feedback and no longer follow the primary relation alone. Including them steepens the fitted slope and assigns secondary growth incorrectly to alpha.
What should be reported with gamma?
State the assumed spark distance, the alpha value used, the current relationship and any apparatus limit near breakdown. Gamma is not just a graph label; it depends on how the secondary region and breakdown condition were identified.
Exam move
Create a small table with measured voltage, converted gap voltage, distance, field, current, normalised current and natural log. Mark the primary interval before calculating any slope. Then identify the secondary upturn and write the separate equation used for gamma. This mirrors the logic in the official worked assignment answer without copying its data.
Rehearse the reduction as an audit trail rather than a calculator sequence. Preserve the original meter readings, record the divider ratio once and place converted gap voltage in a new column. Divide by electrode spacing to confirm that the intended field is constant across the series. Choose and identify the initial current before calculating ratios.
Use natural logarithms because the linearized Townsend relation follows the exponential with base e. Keep distance in the unit that the reported alpha will use. Plot before fitting. Mark the photoelectric or baseline region, the straight primary-growth interval and the secondary upturn. Select the primary interval from physical behaviour rather than from whichever points give the largest correlation coefficient.
Calculate one slope by hand so that the regression output has an independent check. Move each endpoint once and note the change; a large change means the coefficient is sensitive to region selection and should not be reported with excessive precision. Treat residual patterns as evidence.
Random scatter may reflect measurement noise, a low-current plateau may reflect the instrument floor, and systematic upward departure at larger separation signals secondary feedback. Do not force those behaviours into one straight line. Estimate gamma only after alpha is established, using the secondary relationship and a clearly stated spark-distance or near-breakdown assumption.
Finish the report with a reproducibility packet: raw and converted tables, axes and units, selected observations, excluded observations with reasons, fitted expression, parameter units and instrument limits. Add a second field series as a consistency check without pooling unlike regimes. If reduced quantities disagree, report the disagreement as a result to investigate.
This workflow matches the assessment emphasis on labelled regions and defensible coefficients while keeping every inference traceable to a measured quantity.
Working through Measuring Townsend Coefficients in EE509? Sia is AskSia’s AI Electrical Engineering tutor — ask any EE509 Measuring Townsend Coefficients question and get a clear, step-by-step explanation grounded in how EE509 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.