EE509 High Voltage Engineering
EE509 Overview
- The Hong Kong Polytechnic University
- Semester 1, 2026/27
- Postgraduate electrical engineering
- Three-hour closed-book examination
What the subject asks you to do
High Voltage Engineering connects microscopic discharge physics with the design and operation of power equipment. The subject begins with electric fields, dielectric stress and the roles played by gaseous, liquid and solid insulation.
- Assessed by A closed-book written examination and continuous assessment.
- Core method Select the physical mechanism before choosing an equation.
- Hardest step Keeping model conditions, units and phase quantities consistent.
- How to prepare Rebuild derivations, then finish with an engineering decision.
What you get in the full EE509 Exam Bible
- 10 chapters, 32 pages — every examinable topic
- 26 original practice questions, each with a model answer in the Examination format
- 10 worked examples, solved the way EE509 marks
- 11 computed figures, redrawn from the course’s own numbers
- Exam-morning plan for the Examination (60%) — what to revise last, where marks are lost
Free on this page: assessment table, chapter map, one worked example, key terms, FAQ. The rest is in the full exam bible.
How EE509 is assessed
| Component | Weight | Format |
|---|---|---|
| Examination | 60% | Three-hour, closed-book, end-of-subject written examination |
| DO: 4 Assignments (Insulation Breakdown) + 1 Log (In-house Workshop), Optional | 20% | Published alternatives: assignments 20% and log 0%, or assignments 16% and log 4% |
| HKEI: 3 Assignments (High Voltage Equipment) | 18% | After-class exercises for equipment lectures |
| HKEI: 1 Attendance (Visit to HK Electric) | 2% | Attendance record for the industry visit |
The official table totals 100%. Within the university continuous-assessment share, it publishes two alternatives: assignments carry 20% and the optional workshop log 0%, or assignments carry 16% and the log 4%. The combined row above preserves the fixed 20% share without inventing which branch applies in the live gradebook.
Assessment structure
The segment widths reproduce the four published shares and total 100%.
What other students are asking about EE509
- Where can I find lecture notes or study guides for EE509 at PolyU?
- The EE509 study guide in AskSia Library covers High Voltage Engineering in 10 chapters, with the assessment table, a chapter-by-chapter topic map, key terms and a worked example, free to read on this page.
- Is there a final exam in EE509, and how much is it worth?
- Yes. In the offering this AskSia Library guide is built from, Examination carries 60% of the EE509 mark; the full split is Examination 60%, DO: 4 Assignments (Insulation Breakdown) + 1 Log (In-house Workshop), Optional 20%, HKEI: 3 Assignments (High Voltage Equipment) 18%, HKEI: 1 Attendance (Visit to HK Electric) 2%.
- What does EE509 cover on insulation families and failure modes?
- In AskSia Library's EE509 guide, the Insulation Families and Failure Modes chapter explains gas avalanches, liquid impurity paths, solid flashover, tracking and treeing.
- What does EE509 cover on insulating materials in equipment?
- In AskSia Library's EE509 guide, the Insulating Materials in Equipment chapter explains temperature, moisture, loss, fabrication and equipment interfaces.
- What does EE509 cover on ionization and electron avalanches?
- In AskSia Library's EE509 guide, the Ionization and Electron Avalanches chapter explains collision, photon, secondary and attachment processes.
What EE509 covers
The guide moves from electric field stress and insulation selection into gaseous ionization, Townsend and streamer breakdown, Paschen behaviour, corona, vacuum insulation and liquid breakdown.
Electric Fields and Dielectric Stress
potential gradients, flux density, capacitance and design stressVoltage becomes a local stress through geometry
Electric field intensity is force per unit charge, while electric flux density follows the field through the permittivity of the medium.
- Electric field intensity and force on charge
- Flux density, permittivity and dielectric constant
- Potential gradient and field direction
- Current density and conductivity
- Capacitance as charge per potential difference
- Breakdown strength versus design stress
Insulation Families and Failure Modes
gas avalanches, liquid impurity paths, solid flashover, tracking and treeingOne purpose, different failure physics
Gases, liquids and solids all prevent unwanted current, but a useful diagnosis separates their mechanisms. Gas failure grows from electron collisions and avalanches.
- Gaseous avalanche breakdown
- Liquid self healing and contamination
- Solid flashover and tracking
- Treeing at internal imperfections
- Partial discharge in voids
- Interfaces as retained damage sites
Insulating Materials in Equipment
temperature, moisture, loss, fabrication and equipment interfacesSelection is a constrained engineering decision
Insulation is required between turns, coils, phases and earth.
- Inter-turn and inter-coil insulation
- Phase-to-phase and phase-to-earth duties
- Temperature classes and useful life
- Moisture and dielectric loss
- Organic, inorganic and polymer families
- Interfaces, casting and impregnation
Ionization and Electron Avalanches
collision, photon, secondary and attachment processesElectron energy drives multiplication
An applied field accelerates free electrons from cathode toward anode. If a collision transfers more than the molecular ionization energy, another electron and a positive ion are produced.
- Electron kinetic energy in a field
- Collision ionization threshold
- Photoelectric ionization and wavelength
- Secondary cathode emission
- Primary and secondary coefficients
- Electron attachment in electronegative gas
Townsend Current Growth and Breakdown
primary exponential growth, secondary feedback and the spark criterionPrimary growth is exponential
At low pressure in a uniform field, the increase in electron population over a small distance is proportional to the population already present.
- Population balance over a small distance
- Exponential primary current growth
- Secondary cathode feedback
- Townsend spark criterion
- Spark distance and circuit limitation
- Low-pressure uniform-field validity
Measuring Townsend Coefficients
linearised current plots, slope selection and breakdown-region estimationLinearisation reveals the primary coefficient
The experiment varies electrode distance while holding field intensity fixed. Divider readings are converted to actual gap voltage and current is normalised by its initial value.
- Voltage-divider conversion
- Field consistency across distances
- Current normalisation
- Natural-log linearisation
- Primary-region slope for alpha
- Secondary-region estimate for gamma
Attachment and Streamer Breakdown
net electron growth, space charge and rapid filamentary dischargeAttachment changes net carrier growth
Electronegative molecules capture electrons and form heavy negative ions. Eta counts attachment events per electron per distance, so net multiplication depends on alpha minus eta.
- Direct and dissociative attachment
- Attachment coefficient eta
- Net alpha minus eta growth
- Critical field-to-pressure condition
- Space-charge field at avalanche head
- Rapid plasma streamer formation
Paschen Law and Corona Performance
pressure-distance behaviour, inception thresholds and line lossesPaschen behaviour has one physical minimum
Spark voltage depends on pressure-distance product and gas density. Below the minimum, collisions are too rare for efficient ionization.
- Pressure-distance product
- Paschen minimum and two branches
- Temperature and gas-density correction
- Disruptive critical voltage
- Visible corona inception
- Peek and Peterson loss ranges
Post-Breakdown and Vacuum Insulation
glow, arc, particle exchange and field-emission failureGlow and arc are different operating states
After spark breakdown, a discharge can pass through normal and abnormal glow before transitioning into an arc. Glow is luminous and comparatively modest in current.
- Townsend-to-glow transition
- Normal and abnormal glow
- Glow-to-arc transition
- Particle-exchange vacuum mechanism
- Anode-heating field emission
- Cathode microprojection heating
Liquid Purification and Breakdown
test preparation, pure-liquid current regions and impurity bridgesPreparation and measurement belong to one loop
Distillation removes heavy particles while vapour carries gas, water and fine material onward.
- Closed-cycle liquid purification
- Breakdown test-cell geometry
- Pure-liquid current regions
- Gas-bubble elongation
- Water-droplet shape instability
- Particle chains and sublinear gap scaling
It then develops gaseous breakdown through ionization, Townsend avalanches, electron attachment, streamer formation, Paschen behaviour and corona.
Liquid insulation is treated as a condition-sensitive system in which purification, electrode geometry and bubbles, droplets or particles can control the observed strength.
How the assessment changes your study method
The examination carries sixty per cent and is conducted in written form, without books, for three hours.
The current material does not publish its question layout, so revision should focus on durable methods rather than a guessed paper shape. Learn the physical conditions for each model, reproduce the important relationships with correct units, and practise turning a result into a decision. Continuous assessment includes insulation and equipment assignments plus practical learning records.
The published alternative inside one twenty per cent share is preserved in the assessment note below.
Where calculations go wrong
Most expensive errors occur before the calculator: voltage is used where phase voltage is required, millimetres are combined with reciprocal centimetres, radius is confused with diameter, temperature is left in Celsius inside a density relation, or a Townsend expression is applied to a rapid filamentary discharge.
Each chapter therefore pairs a mechanism with a validity check and a short closing sentence. The closing sentence says whether breakdown is self sustaining, whether corona is expected, whether a design limit is exceeded, or which contaminant-control test should follow.
Evidence boundaries
The current teaching set is strongest on insulation foundations, gaseous breakdown and liquid breakdown.
The official syllabus continues through solid insulation, partial discharge, high-voltage networks, gas insulated switchgear and cables. Those topics are acknowledged in the course map but are not expanded into unsupported chapters where detailed notes were not present. All practice scenarios in this guide are independently authored and use new values.
Worked example · free
Check a uniform-gap field before selecting insulation
- 2Convert the gap to centimetres.
- 2Calculate field as voltage divided by distance.
- 2Compare with the design limit and state the decision.
Key terms
- Dielectric Strength
- The maximum electric field stress an insulating material can withstand before breakdown.
- Field Stress
- The local electric field imposed on insulation by voltage, geometry and surrounding media.
- Townsend Coefficient
- A coefficient describing primary ionizing collisions per travel distance or secondary cathode emission per incident ion.
- Electron Attachment
- The capture of a free electron by a molecule to form a negative ion and suppress fast multiplication.
- Streamer
- A rapidly propagating conducting channel produced when avalanche space charge strongly distorts the applied field.
- Paschen Minimum
- The lowest spark voltage on the relationship between breakdown voltage and pressure-distance product.
- Disruptive Voltage
- The conductor voltage at which local ionization and corona begin.
- Visible Inception
- The higher threshold at which corona becomes visibly luminous around a conductor.
- Glow Discharge
- A luminous post-breakdown state with a distributed cathode region and comparatively modest current.
- Arc Discharge
- A high-current, low-gap-voltage plasma state associated with intense heating.
- Treeing
- Branching deterioration within solid insulation or at a conductor interface.
- Purification Loop
- A closed process combining distillation, condensation, drying, filtration and degassing before liquid testing.
EE509 FAQ
What is the examination format?
The published briefing states that the examination is a three-hour, closed-book, end-of-subject written examination worth sixty per cent. The captured material does not state question count, section structure, choice rules or special permitted aids, so prepare the mechanisms and calculations rather than assuming a paper layout.
How does the continuous-assessment alternative work?
One university share totals twenty per cent under either published branch. The four insulation assignments are worth twenty per cent with the optional workshop log at zero, or the assignments are worth sixteen per cent with the log at four. Check the live gradebook for the active branch.
Why is Townsend theory not used for every gas breakdown?
Townsend theory assumes a uniform field, relatively low pressure and enough time for avalanche and secondary processes to develop. Rapid filamentary discharge at atmospheric pressure needs streamer reasoning because avalanche space charge distorts the field and creates a fast conducting channel.
What is the safest way to start a corona calculation?
Convert line voltage to the required phase voltage, turn diameter into radius, correct gas density for pressure and temperature, and calculate the disruptive threshold. Only then compare the voltage ratio with the validity range of the selected empirical loss expression.
How should liquid breakdown be diagnosed?
Begin with condition history and impurity evidence. Gas bubbles, water droplets and solid particles move or deform differently in an electric field. Drying, degassing and filtration target different causes, so controlled repeat tests are more informative than treating one low result as a fixed material property.
Are past examination papers included?
No past examination paper is present in the available materials. The captured assessment examples are assignment questions and one official worked assignment answer. This guide uses their question types and method sequence to create new practice without implying access to a past exam.
What should the final line of a numerical answer say?
It should state the engineering consequence: whether a field exceeds the chosen design limit, whether a discharge reaches a self-sustaining criterion, whether corona is expected, whether an empirical formula is valid, or what diagnostic control should be applied next.
How should I revise closed book?
Rebuild a compact relationship map from memory, then solve short questions without notes. Mark conditions and units before arithmetic. After each result, write one sentence comparing it with a threshold or mechanism. This rehearses the logical solution style described in the published grading information.
Questions students ask in each EE509 chapter
- Why can the same voltage be safe in one gap and unsafe in another?
- Field depends on how rapidly potential changes with position. A wider uniform gap spreads the same voltage over more distance, while a sharp electrode can concentrate the gradient locally. Compare calculated local stress with the stated design criterion rather than judging voltage alone. Chapter 01 · Electric Fields and Dielectric Stress
- Why is self healing not the same as harmless failure?
- A gas can recombine and a liquid can refill a puncture while adjacent solids retain erosion, contamination or deposited products. Assess the whole insulation system and its interfaces, not only whether the main medium appears to recover. Chapter 02 · Insulation Families and Failure Modes
- Why is dielectric strength not enough for selection?
- Continuous temperature, moisture, mechanical form, frequency-dependent loss and manufacturing route can each eliminate a material before its maximum strength matters. Selection begins with the service location and hard limits, then compares electrical properties among surviving candidates. Chapter 03 · Insulating Materials in Equipment
- Why does higher field increase ionization?
- Electrons gain more kinetic energy between collisions, so a greater share of collisions exceed the molecular ionization threshold. The result is a higher probability of carrier multiplication, not merely a direct proportional increase in current. Chapter 04 · Ionization and Electron Avalanches
- Why must alpha times distance be dimensionless?
- It appears inside an exponential. If alpha is per centimetre, distance must be in centimetres. A millimetre-centimetre mismatch changes the exponent by a factor of ten and can create an enormous numerical error. Chapter 05 · Townsend Current Growth and Breakdown
- Why plot the natural logarithm of current ratio?
- Primary Townsend growth is exponential, so taking the natural logarithm produces a line whose slope is alpha. A raw current plot obscures that slope and makes secondary curvature harder to separate from primary growth. Chapter 06 · Measuring Townsend Coefficients
- What does eta greater than alpha mean physically?
- Electron removal exceeds ionizing production under the stated conditions, so the free-electron population cannot sustain ordinary avalanche growth. It does not mean breakdown is impossible under every stronger field or different pressure. Chapter 07 · Attachment and Streamer Breakdown
- Why does voltage rise on both sides of the Paschen minimum?
- At low pressure-distance product, electrons make too few collisions. At high product, collisions are frequent but energy gained between them is smaller. The minimum balances collision opportunity with energy per free path. Chapter 08 · Paschen Law and Corona Performance
- Why can a vacuum break down if it has no gas?
- A perfect vacuum would prevent collision multiplication, but real electrodes contain projections, absorbed gases and surface material. Emission and heating can release particles or vapour, creating the matter needed for a discharge. Chapter 09 · Post-Breakdown and Vacuum Insulation
- Why must a liquid test describe preparation?
- Purity, dissolved gas, water, particles, electrode condition and gap all affect the measured result. A number without those conditions is not a transferable material strength and cannot be scaled safely to equipment. Chapter 10 · Liquid Purification and Breakdown
How to study for the exam
Use three passes. First rebuild electric field, dielectric stress and the differences between gas, liquid and solid failure. Second reproduce the ionization chain, Townsend growth, the spark criterion, attachment and streamer formation from memory. Third solve one Paschen or corona setup and one liquid-diagnosis problem each day.
For every numerical exercise, write the regime, equation, unit conversion, result and engineering conclusion on separate lines. Keep an error log grouped by model choice, units, phase conversion, geometry and interpretation. The evening before the examination, review only that error log and the conditions under which each equation is valid. Do not invent a paper structure that the teaching material does not publish.
Your AI Electrical Engineering tutor for EE509
Stuck on a hard EE509 question? Sia is AskSia’s AI Electrical Engineering tutor — ask any EE509 High Voltage Engineering question and get a clear, step-by-step explanation grounded in how the course is actually taught and assessed. Read this whole study guide free, then take your hardest questions to Sia.