40366 Chap.6 Metallography and Grain Size Measurement
Metallography and Grain Size Measurement
Why microstructure is worth the effort
Grain size, the balance of phases and the defects inside a metal connect what it is made of and how it was processed to how it behaves under load.
The metallography lab gives each group a carbon steel already mounted in Bakelite and ground to 1200 grit, and asks for three things: a properly prepared surface, a grain size measurement and an estimate of composition from the phases seen.
From scratches to grains
Preparation runs from a rough polish to a fine one.
A rough polish with a 6 µm abrasive takes out the grinding scratches, a fine polish at 0.25 µm removes the rough-polish marks, the sample is cleaned between stages and checked under the optical microscope, and staff supervise an etch in 2% Nital that reveals the structure.
Measuring what you see
Grain size is found with the Heyn linear intercept method: random test lines, a count of boundary crossings and a division of true length by that count, with at least 50 grains counted overall.
Images of all three samples need scale bars. Phase fractions measured with image analysis software then place each steel on the low-carbon side of the iron-carbon diagram, where the lever rule converts the pearlite fraction into a carbon content, assuming only ferrite and pearlite are present.
What this chapter covers
- 01
Microstructure as the link between processing and properties
- 02
Grinding, rough polishing and fine polishing
- 03
Etching with Nital to reveal grains
- 04
The Heyn linear intercept method
- 05
Scale bars and representative fields
- 06
Ferrite and pearlite in carbon steels
- 07
The lever rule below 0.76 wt% carbon
Worked example · free
Compare horizontal and vertical intercepts on a ceramic micrograph
- 1Scale: 10 mm on the print is 50 µm, so each printed millimetre is 5 µm and each 80 mm line is 400 µm.
- 1Horizontal count: the start is not counted and the far end on a boundary scores one half, so N = 22.5.
- 1Horizontal intercept: 400 ÷ 22.5 = 17.8 µm.
- 1Vertical intercept: 400 ÷ 12 = 33.3 µm.
- 1Ratio 33.3 ÷ 17.8 = 1.9: the grains are nearly twice as long vertically, so both directions must be measured and reported.
Key terms
- Microstructure
- Arrangement of grains, phases and defects in a material as seen at small scales under a microscope.
- Pearlite
- Layered mixture of ferrite and iron carbide that forms when carbon steel cools slowly through the eutectoid point.
- Ferrite
- Body-centred cubic iron holding very little carbon, the light-etching constituent in a slowly cooled low-carbon steel.
- Lever Rule
- Tie-line calculation that gives the proportion of each phase from the overall composition and the two phase-boundary compositions.
- Rough Polishing
- Polishing stage with a coarser abrasive, here 6 µm, whose job is to remove the scratches left by grinding.
Metallography and Grain Size Measurement FAQ
Why does my polished steel still show scratches under the microscope?
Straight parallel scratches usually mean the coarse polishing stage stopped before the grinding damage was gone. The finer abrasive that follows is too gentle to remove those marks, so go back a stage, check the whole surface under the microscope, clean the sample and only then return to fine polishing.
How many grains should I count for a reliable grain size?
The lab script asks for at least 50 grains in total, which usually means several test lines placed at random and in different directions. Record each line's true length and its crossing count, add them up, and divide the total length by the total count to get one mean intercept.
Do the ends of a test line count as grain boundary crossings?
Normally they do not, because an end point is simply where you stopped drawing. The exception is an end that lands exactly on a boundary, which is scored as half a crossing. Mark these cases on your print so a reader can follow the count.
Why is the Nital etch done with a member of staff?
Nital is an acid solution, so the etching step is carried out under the support of staff, with the protective equipment they specify and their instructions on handling and timing. Treat it as a supervised step: have your polished, clean sample ready and wait for the demonstrator before starting.
Why must every metallography image include a scale bar?
Grain size and spacing are lengths, and without a scale nobody can convert a measurement on the screen or print into micrometres. A scale bar survives resizing, whereas a magnification figure becomes wrong as soon as the image is enlarged or shrunk in a report.
Assessment move
Rehearse the preparation sequence until you can explain what each stage removes and why the order cannot be reversed. Then practise the intercept method on any grain image: draw lines in at least two directions, count crossings with the end-point rule, convert with the scale bar and compare the directions.
Finish with a lever-rule calculation from a stated carbon content to the expected pearlite fraction, using the tie line just above the eutectoid, and write one sentence on its assumptions. Keep your micrographs, counts and calculations together in one table so they can go straight into a report.
Before the session, sketch what a ferrite and pearlite structure should look like at two magnifications, so you know what a representative field is when you see it.
Working through Metallography and Grain Size Measurement in 40366? Sia is AskSia’s AI Engineering tutor — ask any 40366 Metallography and Grain Size Measurement question and get a clear, step-by-step explanation grounded in how 40366 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.