University of Birmingham · FACULTY OF ENGINEERING

40366 Chap.3 Pressure Measurement and Duct Flow

- one subject, every graph, every model, every mark
7 Chapters4-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 3 of 12 · 40366

Pressure Measurement and Duct Flow

Pressure in five words

The A3 fluids lab is the first chance to run a wind tunnel, a small suction tunnel with a 150 by 150 mm working section. It starts by separating static, dynamic and total pressure, and by distinguishing absolute pressure, measured from vacuum, from gauge pressure, measured from the room.

A pitot-static tube senses total and static pressure, and their difference gives the airspeed through the square-root relation.

Continuity and Bernoulli

A duct of changing cross-section is fitted with a row of static tappings and pitot positions.

Continuity says area times velocity stays constant at low speed, so a narrower section flows faster; Bernoulli says static plus dynamic pressure stays constant in the ideal case. Students predict the speed and pressure at each tapping, then compare the measured values with the predictions and explain the differences.

Instruments

A third activity works through manometer calculations.

A U-tube reads a difference as a liquid head using the density of the manometer liquid, an inclined tube trades range for finer resolution, and a barometer with a sealed end reads absolute atmospheric pressure. These ideas return in the lift and drag lab and in later years when airspeed and altitude measurement are corrected for higher speeds.

In this chapter

What this chapter covers

  • 01

    Static, dynamic and total pressure

  • 02

    Absolute and gauge pressure

  • 03

    Pitot-static tubes and airspeed

  • 04

    Continuity in a duct of changing area

  • 05

    Bernoulli and the static pressure dip

  • 06

    Total pressure losses in real ducts

  • 07

    U-tube, inclined and barometer readings

Worked example · free

Size a duct throat for a target suction

Q [5 marks]. AskSia-authored practice. In a fan-driven duct a pitot tube reads a total gauge pressure of 25.0 Pa, taken as the same at every station with no losses. The inlet, 0.090 m² in area, has a static gauge pressure of −14.2 Pa. A designer wants −36.25 Pa at a throat to drive a sampling line. With air density 1.225 kg/m³, find the inlet speed, the throat speed and the throat area. The marks shown are AskSia study marks and not an official University scheme.
Figure 3.1.Figure 3.1. An AskSia fan-driven duct with a measured total gauge pressure of 25.0 Pa. The upper sketch gives the speed at each station; the lower line shows static gauge pressure falling from −14.2 Pa at the inlet to the −36.25 Pa target at the throat.FlowInlet 8.0 m/sThroat 10.0 m/sExit 8.0 m/sTotal 25.0 Pa0 Pa ambient−14.2 Pa−36.25 PaStatic gauge pressure
Figure 3.1. An AskSia fan-driven duct with a measured total gauge pressure of 25.0 Pa. The upper sketch gives the speed at each station; the lower line shows static gauge pressure falling from −14.2 Pa at the inlet to the −36.25 Pa target at the throat.
  • 1Inlet dynamic pressure = total minus static = 25.0 − (−14.2) = 39.2 Pa.
  • 1Inlet speed = √(2 × 39.2 ÷ 1.225) = √64 = 8.0 m/s.
  • 1Throat dynamic pressure = 25.0 − (−36.25) = 61.25 Pa, so throat speed = √(2 × 61.25 ÷ 1.225) = √100 = 10.0 m/s.
  • 1Continuity: throat area = 0.090 × 8.0 ÷ 10.0 = 0.072 m².
  • 1Check: the throat is smaller and faster, and its static pressure is lower, consistent with total pressure held constant.
The inlet flows at 8.0 m/s and the throat must run at 10.0 m/s, which continuity delivers with a throat of 0.072 m². The static gauge pressure then falls from −14.2 Pa at the inlet to the −36.25 Pa target.
Sia tip — Subtract static from total before taking any square root, and keep the minus signs of gauge readings inside brackets.
Glossary

Key terms

Static Pressure
Pressure exerted by a fluid independent of its motion, sensed by a port that faces across the flow.
Total Pressure
Static plus dynamic pressure, picked up by a pitot opening that points straight into the oncoming flow.
Pitot-Static Tube
Probe combining a forward-facing total pressure opening with side static ports, used to work out airspeed.
Continuity Equation
Statement that mass flow is the same at every section of a duct, so area times velocity is constant at low speed.
Inclined Manometer
Liquid gauge whose tube is tilted so a small vertical head moves the meniscus a longer distance along the scale.
FAQ

Pressure Measurement and Duct Flow FAQ

How do you calculate airspeed from a pitot-static tube?

Subtract the static reading from the total reading to get the dynamic pressure in pascals, double it, divide by the air density and take the square root. At standard sea level the density is 1.225 kg per cubic metre, and the result comes out in metres per second.

Why must the wind tunnel fan speed be changed gradually?

Sudden changes in fan speed wear or damage the motor, so the script steps the fan up in increments of no more than twenty percentage points and brings it down through intermediate settings, letting the readings settle each time before you record them.

Which density goes into the manometer equation?

Use the density of the liquid in the manometer, such as water, never the density of the air being measured. Mixing them up gives a pressure roughly eight hundred times too small, which any sanity check on the result should catch.

What does an inclined manometer improve?

Tilting the tube makes a given vertical head move the liquid further along the scale, because the head equals the scale movement times the sine of the angle. Readings become finer, at the cost of a smaller range, which suits small pressure differences.

What is the difference between absolute and gauge pressure?

Absolute pressure is measured from a perfect vacuum, while gauge pressure is measured relative to the local surroundings. Most manometers and dial gauges display gauge pressure, while a barometer, with its sealed vacuum end, reads absolute pressure.

Study strategy

Assessment move

Start by building a one-page table of the five pressure terms with their symbols, how each is measured and its sign inside a suction tunnel. Then practise the chain from millimetres of water to pascals to metres per second until it is automatic, keeping the two densities apart.

For the duct activity, predict the velocity and static pressure at each tapping from the area ratio before the session, so the measured values have something to be compared with. Afterwards plot measured against predicted, look for where they part company, and write down your own explanation for the gap.

Finish by working one manometer and one barometer conversion of your own, choosing fluids and readings different from the worksheet so the method is tested rather than memorised.

Working through Pressure Measurement and Duct Flow in 40366? Sia is AskSia’s AI Engineering tutor — ask any 40366 Pressure Measurement and Duct Flow question and get a clear, step-by-step explanation grounded in how 40366 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 17 of your subjects at University of Birmingham, plus 1,000+ more Bibles across the AskSia library.
Sia - your 40366 tutor, unlimited, worked the way the exam marks it
The full 4-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works
40366 · LC Practical and Design Skills for Materials Science/Aerospace Engineering - independent study guide on the AskSia Library. More University of Birmingham subjects · Microeconomics across all universities