ELEC5570M Control Systems Design
ELEC5570M Overview
- University of Leeds
- Semester 1 2026/27
- 6 chapters
- Electrical Engineering
ELEC5570M Control Systems Design develops the modelling and analysis habits needed to connect a physical plant with a controller design.
- Assessment Assignment 30%, Final Assessment 70%.
- Model first Keep the physical boundary and assumptions visible.
- Check poles Stability precedes final-value and transient claims.
- Use Minerva Confirm the final format and later-unit material on the live module site.
How ELEC5570M is assessed
| Component | Weight | Format |
|---|---|---|
| MATLAB-based assignment and report | 30% | Covers Units 1 and 2. Released 16 November 2026 and due 26 November 2026. |
| Final Assessment | 70% | Covers Units 1, 2 and 3 in the January examination period. Published submission time is three hours. |
Current ELEC5570M dates
| Date | Item | Control |
|---|---|---|
| 16 November 2026 | Assignment release | The MATLAB-based assignment and report contributes 30%. |
| 26 November 2026 | Assignment deadline | The published deadline is 2:00 pm UK time. |
Dates are as published in the Semester 1, 2026/27 module introduction and assessment overview. Confirm exact deadlines and submission settings in the live LMS.
What ELEC5570M covers
Six connected chapters develop the captured Unit 1 route from feedback structure and physical modelling to transfer functions, state space, specifications and stability.
Feedback Control Foundations
Open-loop, feed-forward and closed-loop structures, signal dependencies, disturbances and feedback trade-offs.Feedback Control Foundations identifies the signals and decisions that make a control strategy open loop, feed-forward or closed loop. A system description begins with a boundary, objective, input, output, control action, disturbance and constraint.
- System boundaries and objectives
- Open-loop control
- Feed-forward compensation
- Closed-loop feedback
- Reference and error signals
- Disturbance rejection
Physical and Mathematical Modelling
System boundaries, approximations, equilibrium and compatibility relations, component laws and dynamic equations.Physical and Mathematical Modelling separates the real plant, a chosen physical approximation, its mathematical equations and the later analysis. The boundary determines which flows, forces, currents and voltages cross into the model.
- Dynamic investigation stages
- System boundaries
- Equilibrium relations
- Compatibility relations
- Electrical component laws
- Mechanical free bodies
Laplace Models and Transfer Functions
Single-sided transforms, initial conditions, zero-state input-output ratios, limit theorems and frequency response.Laplace Models and Transfer Functions converts time-domain differential equations into algebraic s-domain relations.
- Single-sided Laplace transform
- Derivative and integral rules
- Initial conditions
- Transfer-function definition
- Initial and final values
- Frequency response
Poles, Zeros and Feedback Blocks
Response modes, residues, canonical negative feedback, nested-loop reduction and characteristic equations.Poles, Zeros and Feedback Blocks connects algebraic structure with time response and signal flow. Poles create natural response modes: their real parts control decay or growth and their imaginary parts control oscillation.
- Pole locations
- Zero influence
- Response residues
- Block-diagram elements
- Canonical feedback
- Nested-loop reduction
State-Space Models
State selection, matrix dimensions, input and output equations, transfer-function recovery and state feedback.State-Space Models arrange dynamic systems as first-order equations. The state vector contains variables that determine future behaviour with the future input. For n states, p inputs and m outputs, A is n by n, B is n by p, C is m by n and D is m by p.
- State selection
- First-order equations
- Matrix dimensions
- Output equations
- Transfer-function recovery
- State feedback
Performance Specifications and Stability
Second-order response indices, pole regions, steady-state error, left-half-plane stability and Routh tests.Performance Specifications and Stability turns desired response features into conditions on a closed-loop characteristic equation.
- Second-order standard form
- Damping and natural frequency
- Rise and peak time
- Overshoot and settling
- Steady-state error
- Routh stability
The captured teaching material begins by distinguishing open-loop, feed-forward and closed-loop strategies, then turns physical electrical and mechanical systems into differential equations. Laplace transforms convert those equations into transfer functions, while poles, zeros and block diagrams reveal response modes and feedback structure. State-space models retain internal variables and support multi-variable reasoning.
The final part of the captured Unit 1 material translates response requirements into damping, natural frequency, overshoot, settling time, steady-state error and stability conditions.
The published assessment has two components. A MATLAB-based assignment and report covers Units 1 and 2 and contributes 30%.
The Final Assessment covers Units 1, 2 and 3 and contributes 70%; the module introduction places it in January and gives a three-hour submission time. The captured source does not state the final question count, section structure, book status or module-specific permitted materials, so those operational details must be checked on Minerva.
This guide follows the detailed Unit 1 evidence available in the source.
It does not fabricate teaching content for the later controller-design and digital-control units whose lecture materials were not captured. Each numerical model is original, while the equations and solution habits are grounded in the Leeds notes and solved example sheets.
The recurring method is to define the boundary and signals, write the governing relation, arrange the model, calculate with visible assumptions, and finish with a physical interpretation.
Worked example · free
Read a second-order response from its denominator
- 2Match s squared plus 2 zeta omega n s plus omega n squared: omega n is 4 rad/s and zeta is 0.625.
- 2Compute damped frequency as 3.123 rad/s, giving peak time 1.006 s.
- 2Use 4 divided by zeta omega n to estimate settling time as 1.60 s.
- 2Evaluate the exponential overshoot relationship to obtain about 8.08%.
Key terms
- Open-loop control
- A strategy in which control action does not depend on measured output.
- Closed-loop control
- A strategy in which measured output influences control action through an error signal.
- Feed-forward control
- A strategy that adjusts control action from a measured disturbance before output error develops.
- Transfer function
- The zero-initial-condition ratio of output transform to input transform for a linear system.
- Pole
- A denominator root that determines a natural response mode.
- Zero
- A numerator root that changes how response modes appear in a chosen channel.
- State variable
- A variable in a minimal set that determines future model behaviour with the future input.
- Damping ratio
- The dimensionless parameter that shapes second-order oscillation and overshoot.
- Natural frequency
- The frequency scale set by the constant term of a normalised second-order denominator.
- Settling time
- The time required for a response to enter and remain within a stated final-value band.
- Steady-state error
- The limiting difference between reference and output when that limit exists.
- Routh array
- A coefficient construction whose first-column sign changes count right-half-plane roots.
ELEC5570M FAQ
How difficult is this module?
The source does not publish a difficulty rating or pass rate. It does show a broad mathematical workflow: physical modelling, transforms, matrix models, transient specifications and stability. The final contributes 70%, covers all three units and has a published three-hour duration, so fluency in choosing and checking a method matters as much as algebraic execution.
What is the assessment structure?
A MATLAB-based assignment and report contributes 30% and covers Units 1 and 2. The Final Assessment contributes 70% and covers Units 1, 2 and 3. The assignment release and deadline are published for November 2026, while the final is placed in the January examination period.
What is known about the Final Assessment?
The captured module introduction states that it is in January, lasts three hours and covers all three units. It does not publish the number of sections, question types, per-question marks, book status or a module-specific permitted-materials list. Check the current Minerva instructions for those operational details.
Does this guide cover every unit in the module?
It develops the detailed Unit 1 teaching files available in the capture. The syllabus names Unit 2 controller design and Unit 3 digital control, but their lecture materials were not present. Use the official Minerva resources for those units rather than treating generic control theory as course-specific evidence.
Are past final papers available in the captured folder?
No past final paper or final marking scheme appears in the captured folder. It does contain example sheets, worked solutions and four Unit 1 examples. The practice here is original and follows demonstrated method types without copying or lightly rewriting proprietary question stems.
How should I begin a modelling problem?
Choose the system boundary, define variables and positive directions, write equilibrium or compatibility relations, and then apply component laws. Only after the physical equation is stable should you transform it or arrange it into state space. This sequence makes signs, units and assumptions auditable.
How should I check a stability answer?
Use the closed-loop characteristic equation, not the open-loop denominator alone. Confirm that every pole has negative real part, or apply the Routh first-column sign test when parameters remain symbolic. Then check performance separately, because a stable design can still be too slow or too oscillatory.
Questions students ask in each ELEC5570M chapter
- Why can feedback become unstable?
- Delay, phase shift or an incorrect action direction can make the controller reinforce a deviation instead of opposing it. Stability depends on the complete loop dynamics, not on the controller label alone. Chapter 01 · Feedback Control Foundations
- How detailed should a model be?
- Use the simplest representation that preserves mechanisms relevant to the design question. A model can be too simple to represent the plant or too complex to support clear analysis. Chapter 02 · Physical and Mathematical Modelling
- Why are initial conditions zero in a transfer function?
- The definition isolates the system's input-output dynamics. Non-zero initial energy contributes a separate natural-response term rather than changing the transfer function. Preserve that term when the full response, rather than the transfer ratio, is required. Chapter 03 · Laplace Models and Transfer Functions
- What does moving a pole left do?
- A more negative real part produces faster exponential decay. For a complex pair, the imaginary part still sets oscillation frequency while the real part sets the envelope. Chapter 04 · Poles, Zeros and Feedback Blocks
- Is state selection unique?
- No. Invertible coordinate changes can describe the same dynamics. Choose states that make physical interpretation or design convenient and record their order explicitly. Keep that ordering consistent in every matrix and feedback vector. Chapter 05 · State-Space Models
- What does damping ratio control?
- For the standard second-order model it governs oscillatory character and percentage overshoot. Together with natural frequency it also sets the real pole part and settling rate. Chapter 06 · Performance Specifications and Stability
How to study for the exam
Study the captured Unit 1 material as a connected modelling chain. Begin with signal paths: name the reference, output, disturbance, controller and measurement, and decide whether action is open loop, feed-forward or feedback. Next practise moving from a physical boundary to equations by writing balances and component laws before simplifying.
Transform those equations with initial conditions visible, then set them to zero only when forming a transfer function. Read poles as modes and zeros as influences on modal amplitude, and reduce block diagrams from the innermost complete loop outward. For state space, define the state order beside every matrix and verify dimensions before inversion.
Finish with second-order specifications, steady-state error and Routh stability, always checking closed-loop poles before applying limit theorems. Rework the captured example-sheet solution types with fresh numbers. Maintain an error log organised by boundary, sign, units, initial condition, coefficient matching, matrix order and stability condition.
Complete revision for Units 2 and 3 from Minerva because those teaching files were not present in the capture.
Your AI Electrical Engineering tutor for ELEC5570M
Stuck on a hard ELEC5570M question? Sia is AskSia’s AI Electrical Engineering tutor — ask any ELEC5570M Control Systems Design question and get a clear, step-by-step explanation grounded in how the course is actually taught and assessed. Read this whole study guide free, then take your hardest questions to Sia.