Chapter 6 of 6 · ELEC5570M

Performance Specifications and Stability

Performance Specifications and Stability turns desired response features into conditions on a closed-loop characteristic equation. In the standard second-order model, natural frequency sets a time scale while damping ratio shapes oscillation and overshoot. Rise time, peak time, settling time and percentage overshoot impose different pole-region constraints.

Steady-state error follows from the error transfer function and a valid final-value theorem. Stability requires every closed-loop pole to have negative real part. The Routh array counts right-half-plane roots through sign changes in its first column and is especially useful when gains remain symbolic.

In this chapter

What this chapter covers

  • 01

    Second-order standard form

  • 02

    Damping and natural frequency

  • 03

    Rise and peak time

  • 04

    Overshoot and settling

  • 05

    Steady-state error

  • 06

    Routh stability

Worked example · free

Calculate second-order response indices

Q [8 marks]. For denominator s squared plus 5s plus 16, find natural frequency, damping, peak time, settling time and overshoot.
The curve labels rise, peak and settling landmarks on an underdamped step response, with the dashed line showing the final value around which the transient decaThe curve labels rise, peak and settling landmarks on an underdamped step response, with the dashed line showing the final value around which the transient decays.final valuepeakrisepeak timesettling
The curve labels rise, peak and settling landmarks on an underdamped step response, with the dashed line showing the final value around which the transient decays.
  • 2Match coefficients to obtain omega n=4 and zeta=0.625.
  • 2Compute damped frequency 3.123 rad/s and peak time 1.006 s.
  • 2Estimate settling time as 1.60 s.
  • 2Evaluate percentage overshoot as about 8.08%.
The response indices are omega n 4 rad/s, zeta 0.625, peak time 1.006 s, settling time 1.60 s and overshoot 8.08%. The practice weighting is not official.
Sia tip — Normalise the denominator and verify stability before using response formulas.
Glossary

Key terms

Peak time
The time at which an underdamped step response first reaches its maximum.
Percentage overshoot
The first peak above final value expressed as a percentage of final value.
Asymptotic stability
The property that every natural mode decays to zero with time.
FAQ

Performance Specifications and Stability FAQ

What does damping ratio control?

For the standard second-order model it governs oscillatory character and percentage overshoot. Together with natural frequency it also sets the real pole part and settling rate.

Why check stability before steady error?

The final-value theorem requires the relevant poles to lie in the left half-plane. An unstable response does not approach the finite value suggested by an invalid limit calculation.

What does a Routh sign change count?

Each sign change down the first column corresponds to one right-half-plane root. Zero sign changes is the condition for no unstable roots under the ordinary criterion construction.

Why normalise a second-order denominator before matching formulas?

The standard form has a leading coefficient of one, so its s coefficient equals 2 zeta omega_n and its constant term equals omega_n squared. Matching an unnormalised polynomial directly assigns the wrong frequency and damping ratio whenever the leading coefficient differs from one.

Divide the complete denominator first, retain units, and then check that the reconstructed coefficients reproduce the original polynomial after multiplication by the removed factor.

How does a pole plot encode settling and oscillation?

For a complex pair, the negative real part sets the exponential decay envelope and the imaginary magnitude sets the damped oscillation frequency. Distance from the origin gives natural frequency, while the angle relative to the negative real axis relates to damping ratio. A vertical boundary can represent a minimum decay rate, and a constant-damping sector can limit overshoot.

Acceptable poles must satisfy all specified regions rather than only lying somewhere in the left half-plane.

What input information is needed for steady-state error?

The error depends on both the loop and the input type. A step, ramp and higher-order polynomial input contribute different powers of 1/s, so the same system can have different limiting errors for each. Form the correct error transfer expression, insert the input transform, and only then take the limit after checking pole conditions.

Quoting a type number or a constant without identifying the input can conceal an otherwise incorrect conclusion.

What if the first element of a Routh row is zero?

A zero leading element prevents the next ordinary division even when the rest of the row is not zero. Replace it temporarily with a small positive epsilon, continue the array and inspect the sign behaviour as epsilon approaches zero from above. A complete row of zeros is a different special case and signals symmetric roots; it requires an auxiliary polynomial.

Distinguishing these cases avoids silently dividing by zero or reporting a false stable range.

Why is stability not the same as satisfactory performance?

Left-half-plane poles guarantee decay for a continuous linear model, but they may lie so close to the imaginary axis that settling is unacceptably slow or oscillation is excessive. Stable poles can also produce poor tracking, large control effort or weak robustness.

Apply time-domain and steady-state specifications after establishing stability, then consider whether the controller remains feasible under uncertainty and actuator constraints. A stable design is a prerequisite, not the final performance verdict.

Study strategy

Exam move

Normalise every characteristic polynomial before matching it to the standard second-order denominator. Extract natural frequency from the constant term and damping ratio from the s coefficient, then compute damped frequency, peak time, settling time and overshoot with units visible. Sketch the corresponding pole pair and connect real part with decay and imaginary part with oscillation.

Translate maximum settling time into a vertical pole boundary and maximum overshoot into a damping-ratio sector. For steady-state error, form the error transfer function, insert the specified input transform and verify final-value conditions. Build Routh arrays from descending coefficients and count sign changes down the first column. When a gain remains symbolic, solve the first-column inequalities for a stable range.

Finish by checking performance inside that range because left-half-plane poles can still be slow or lightly damped. Record errors under unnormalised coefficients, wrong input type, invalid final-value use, row sign error and stability confused with acceptable performance.

Working through Performance Specifications and Stability in ELEC5570M? Sia is AskSia’s AI Electrical Engineering tutor — ask any ELEC5570M Performance Specifications and Stability question and get a clear, step-by-step explanation grounded in how ELEC5570M is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 8 of your subjects at University of Leeds, plus 1,000+ more Bibles across the AskSia library.
Sia - your ELEC5570M tutor, unlimited, worked the way the exam marks it
The full 4-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works