PHYS7470 Chap.7 Electricity Bills, Demand and Power Factor
Electricity Bills, Demand and Power Factor
A bill prices more than energy
Electricity bills can combine customer charges, accumulated energy, peak demand, adjustments, ratchets and power-factor rules. Kilowatt-hours measure energy consumed over time, while kilowatts measure the rate of use during an interval. Confusing them attaches the wrong tariff rate to the wrong physical quantity.
Begin a bill analysis by listing each component, its driver and its calculation rule rather than treating the invoice total as a single energy price.
Short peaks can create long costs
Demand charges follow the highest relevant interval rather than total monthly consumption. Two large machines overlapping briefly can add little energy yet establish a costly peak.
A demand ratchet can then preserve a percentage of a prior peak as a minimum billed demand in later months. The physical event ends, but the tariff retains its memory.
Graphing actual peak and billed demand together reveals when the invoice is controlled by historical rather than current load.
Power factor enters through the tariff
The course's worked sequence corrects current demand using the tariff's power-factor rule, calculates the ratchet floor and selects the greater candidate. Tariff conventions vary, so the equation printed in the question or current schedule controls.
Improving power factor can lower the corrected candidate without lowering the bill when the ratchet remains higher. A useful result therefore names the binding constraint and does not assume that a technically beneficial change produces immediate savings.
Recommendations follow the charge driver
Reducing runtime and consumption targets energy charges.
Sequencing equipment can lower peak demand without materially changing kilowatt-hours. Event logging helps explain a solitary spike, while repeated low power factor may justify technical investigation. Customer charges may remain fixed and adjustments or taxes follow their own rules.
Calculate savings component by component, preserve the interval and look-back assumptions, and avoid counting one operational change against more than one bill line.
What this chapter covers
- 01
Energy charge
- 02
Demand charge
- 03
Demand ratchet
- 04
Power factor
- 05
Billed demand
- 06
Load control
Worked example · free
Apply correction and ratchet
- 3Calculate both candidate billed demands.
- 3Choose the maximum and price it.
Key terms
- Billed Demand
- The demand quantity selected by the tariff for charging.
- Demand Ratchet
- A minimum billed demand tied to a previous peak.
- Power Factor
- The ratio of real power to apparent power, used by some tariffs to adjust current demand and therefore relevant to cost only through the printed billing rule, current load and its interaction with any ratchet floor.
Electricity Bills, Demand and Power Factor FAQ
What is the difference between kW and kWh?
Kilowatts measure instantaneous or interval power demand, while kilowatt-hours accumulate energy use over time. They are priced by different bill components and cannot be substituted in one another's tariff formula. Equipment sequencing can reduce the first without materially changing the second. Runtime reduction targets the energy quantity instead.
Why can a short peak be expensive?
It can set the monthly demand charge and create a ratchet floor that affects later bills even when the extra energy consumed during the event is small. An event log helps connect the recorded peak with the operating cause.
How is billed demand selected?
Apply the tariff's power-factor rule to current demand, calculate any floor from the prior peak and ratchet percentage, then use the greater candidate when the tariff specifies a maximum test. Name the binding candidate before pricing the demand charge.
Exam move
Create a bill ledger for customer, energy, demand, adjustment and tax charges. Record the interval length, seasonal rule, power-factor convention, ratchet percentage and look-back period before modelling. Graph kilowatt-hours, actual peak, corrected demand and billed demand to expose the active constraint. For each recommendation, state exactly which bill line changes and which components remain fixed.
Rework the maximum test in a fixed order: calculate corrected current demand under the printed tariff rule, calculate the ratchet floor from the prior peak and select the greater amount. Name the binding candidate before multiplying by the demand rate. Add event notes for unusual peaks and test whether equipment sequencing changes kilowatts, kilowatt-hours or both.
If power-factor correction lowers current demand but the ratchet still binds, state that the technical effect does not yet change the billed-demand line. Recalculate a complete invoice component by component rather than applying a percentage to the total. This practice keeps physical controls connected to the tariff mechanism that can actually produce savings.
Working through Electricity Bills, Demand and Power Factor in PHYS7470? Sia is AskSia’s AI Physics tutor — ask any PHYS7470 Electricity Bills, Demand and Power Factor question and get a clear, step-by-step explanation grounded in how PHYS7470 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.