The Hong Kong Polytechnic University · FACULTY OF ELECTRICAL ENGINEERING

EE509 Chap.1 Electric Fields and Dielectric Stress

- one subject, every graph, every model, every mark
7 Chapters2-page Bible
Our own words - no uploaded lecturer files
Updated for this semester
Chapter 1 of 10 · EE509

Electric Fields and Dielectric Stress

Voltage becomes a local stress through geometry

Electric field intensity is force per unit charge, while electric flux density follows the field through the permittivity of the medium. Potential records work per charge and the electric field is the negative spatial gradient of potential. The negative sign gives direction toward lower potential.

This is why a nameplate voltage is not yet an insulation demand: spacing, electrode shape and material boundaries decide how sharply potential changes and where the field is concentrated.

Design compares demand with capability

Dielectric breakdown strength is the maximum stress a material can withstand before losing insulation. Calculated field stress is the operating demand.

Pressure, temperature, humidity, waveform, surface condition and material imperfections alter the margin, so a catalogue strength cannot be treated as a universal limit. A sound answer states geometry, converts length units, calculates field and names the criterion used for comparison.

In this chapter

What this chapter covers

  • 01

    Electric field intensity and force on charge

  • 02

    Flux density, permittivity and dielectric constant

  • 03

    Potential gradient and field direction

  • 04

    Current density and conductivity

  • 05

    Capacitance as charge per potential difference

  • 06

    Breakdown strength versus design stress

  • 07

    Revision protocol: state geometry and waveform, standardise the distance unit, predict where stress peaks, calculate the supported field quantity, compare it with the named design or breakdown criterion, and finish with a direction and order-of-magnitude check that can expose a hidden unit conversion

Worked example · free

Check a uniform insulation gap

Q [6 marks]. A new example applies 21 kV across a 7 mm uniform gap. Find field stress and compare it with an 18 kV/cm design limit. The marks shown for this AskSia exercise are not an official PolyU allocation.
Potential falls as position increases.Potential falls as position increases. The red arrow shows that electric field magnitude is the steepness of the blue potential profile, with direction toward lower potential.E = minus gradientdistancepotentialhighlow
Potential falls as position increases. The red arrow shows that electric field magnitude is the steepness of the blue potential profile, with direction toward lower potential.
  • 2Convert millimetres to centimetres.
  • 2Divide voltage by distance.
  • 2State the design decision.
Seven millimetres is 0.7 cm. The field is 21/0.7 = 30 kV/cm, above the stated 18 kV/cm design limit. The design fails this criterion even though the calculation alone does not prove immediate physical breakdown.
Sia tip — Put the distance conversion on its own line before dividing.
Glossary

Key terms

Electric Field
Force per unit charge at a point, expressed in volts per metre or a consistent high-voltage unit.
Flux Density
Electric flux per area, related to field through the medium permittivity.
Equipotential Surface
A surface on which potential is constant, as occurs on a conductor in electrostatic equilibrium.
Design Stress
The permitted operating field used for an engineering check, normally below breakdown strength.
FAQ

Electric Fields and Dielectric Stress FAQ

Why can the same voltage be safe in one gap and unsafe in another?

Field depends on how rapidly potential changes with position. A wider uniform gap spreads the same voltage over more distance, while a sharp electrode can concentrate the gradient locally. Compare calculated local stress with the stated design criterion rather than judging voltage alone.

What unit mistake is most common in field calculations?

Combining kilovolts with millimetres while reporting kilovolts per centimetre. Convert the gap before division and verify that the exponent or ratio is dimensionally consistent. A hidden factor of ten can reverse the design conclusion.

Does exceeding a design stress prove breakdown occurred?

No. It proves the arrangement fails the stated design criterion. Breakdown strength and the permitted design stress are different thresholds, and the calculation should name which one is being applied rather than claiming more than the evidence supports.

Study strategy

Exam move

Rebuild the chain from potential to gradient, field, flux density and stress without notes. Work five short uniform-gap conversions, changing millimetres to centimetres before each division. Then sketch one non-uniform electrode and explain where stress concentrates. Finish every exercise with a comparison sentence that names the design or breakdown criterion.

Start a second pass by sorting each quantity into cause, response or limit. Potential difference and geometry establish the cause; field intensity and flux density describe the response; usable stress and breakdown strength supply different limits. Write the unit beside every symbol before calculating. For a parallel gap, use one consistent pair such as kilovolts and centimetres.

For a non-uniform gap, replace the single division with a sketch that identifies the likely peak. The purpose is not to invent a numerical field distribution but to show why an average value may miss the critical location. Next practise boundary reasoning. Mark a conductor as equipotential, show that its internal electrostatic field is zero, and draw field lines normal to the surface.

At a material interface, note that permittivity changes the relation between field and flux density. Use those statements to explain why voids, edges and protrusions deserve attention even when the applied voltage is unchanged. Build three short decision records. In each, list the supplied voltage, distance, waveform convention, material value and environmental conditions.

Calculate only what the data support, then label the conclusion as a design check rather than an observation of breakdown. If the question gives a catalogue strength but no safety factor, state that limitation instead of silently treating the catalogue value as an operating allowance. Finish with an error audit.

Reverse the unit conversion, estimate the expected order of magnitude, and ask whether increasing distance lowered the computed stress. A result that moves the wrong way is a conceptual warning, while a factor-of-ten difference usually points to centimetres and millimetres. This routine makes the final comparison concise because geometry, units and criterion have already been made explicit.

Working through Electric Fields and Dielectric Stress in EE509? Sia is AskSia’s AI Electrical Engineering tutor — ask any EE509 Electric Fields and Dielectric Stress question and get a clear, step-by-step explanation grounded in how EE509 is taught and assessed. Read this chapter free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 24 of your subjects at The Hong Kong Polytechnic University, plus 1,000+ more Bibles across the AskSia library.
Sia - your EE509 tutor, unlimited, worked the way the exam marks it
The full 2-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works