ELEC5205 Overview

High Voltage Engineering
— Connect dielectric failure, test evidence and equipment design decisions.
  • Semester 2 2026
  • Postgraduate
  • Closed-book final exam
  • Camperdown/Darlington

Failure physics and equipment decisions

High Voltage Engineering begins with the microscopic events that turn an insulating gas into a conducting path. Electron energy, collision distance, ionisation and attachment determine avalanche growth.

  • Start with the field Geometry decides where ionisation, heating or dielectric stress concentrates.
  • Read evidence cautiously Calibrated pulses, gases and ageing products support diagnoses with explicit limits.
  • Calculate the duty Line, cable and breaker choices follow stated electrical and thermal constraints.
Why read this guide

What you get in the full ELEC5205 Exam Bible

  1. 12 chapters, 50 pages — every examinable topic
  2. 30 original practice questions, each with a model answer in the Final exam format
  3. 12 worked examples, solved the way ELEC5205 marks
  4. 15 computed figures, redrawn from the course’s own numbers
  5. Exam-morning plan for the Final exam (40%) — what to revise last, where marks are lost

Free on this page: assessment table, chapter map, one worked example, key terms, FAQ. The rest is in the full exam bible.

ELEC5205 · University of Sydney
An independent, AskSia-authored study guide. AskSia is not affiliated with, endorsed by, or sponsored by University of Sydney; the course code and name are used for identification only.
Assessment

How ELEC5205 is assessed

ComponentWeightFormat
Laboratory30%Three group laboratory reports, 10% each
Assignment20%Individual project on a high-voltage engineering application
Mid-semester test10%Closed book, one hour, scheduled in Week 7 on modules M1 through M5
Final exam40%Closed book, 2.5 hours, cumulative across every module

The published weights total 100%. No separate attendance condition was identified in the reviewed assessment evidence. Pass eligibility requires a final-examination result of at least 35%.

Assessment structure

30%20%10%40%

Laboratory, assignment, mid-semester test and final exam weights total 100%.

Other students are asking · ELEC5205

What other students are asking about ELEC5205

Where can I find lecture notes or study guides for ELEC5205 at USyd?
The ELEC5205 study guide in AskSia Library covers High Voltage Engineering in 12 chapters, with the assessment table, a chapter-by-chapter topic map, key terms and a worked example, free to read on this page.
Is there a final exam in ELEC5205, and how much is it worth?
Yes. In the offering this AskSia Library guide is built from, Final exam carries 40% of the ELEC5205 mark; the full split is Laboratory 30%, Assignment 20%, Mid-semester test 10%, Final exam 40%.
What does ELEC5205 cover on nonuniform fields, pressure and vacuum?
In AskSia Library's ELEC5205 guide, the Nonuniform Fields, Pressure and Vacuum chapter explains compare spatial ionisation growth with surface-controlled breakdown regimes.
What does ELEC5205 cover on corona and stepped breakdown?
In AskSia Library's ELEC5205 guide, the Corona and Stepped Breakdown chapter explains track local inception, space-charge feedback and propagating leaders.
What does ELEC5205 cover on solid, liquid and surface breakdown?
In AskSia Library's ELEC5205 guide, the Solid, Liquid and Surface Breakdown chapter explains distinguish treeing, tracking and flashover by path and timescale.
Weights, dates and every chapter are set out with their sources further down this page.
Contents · every chapter, one map

What ELEC5205 covers

Twelve source-led chapters move from discharge physics through diagnostics, transmission equipment, protection and commissioning.

01

Gas Avalanche and Paschen Law

Relate electron multiplication, streamer formation and pressure-distance scaling

From collision to conducting channel

Gas breakdown begins when free electrons gain enough energy between collisions to ionise molecules.

  • Effective Ionisation
  • Avalanche Growth
  • Streamer Criterion
  • Paschen Law
  • Pressure-Distance Boundary
  • Uniform-Field Assumption
In the full guide: 4 pages · 3 practice questions · 1 figure
02

Nonuniform Fields, Pressure and Vacuum

Compare spatial ionisation growth with surface-controlled breakdown regimes

Three regimes, three controlling questions

A nonuniform gap requires integration of the local effective ionisation coefficient because field varies along the electron path.

  • Nonuniform Integral
  • Coaxial Field
  • Quasi-Uniform Gap
  • Electrode Conditioning
  • Compressed Gas
  • Vacuum Breakdown
In the full guide: 3 pages · 2 practice questions · 1 figure
03

Corona and Stepped Breakdown

Track local inception, space-charge feedback and propagating leaders

Local activity before full breakdown

Corona occupies the extreme-field region near sharp hardware and can persist below whole-gap breakdown voltage.

  • Corona Inception
  • Streamer Zone
  • Space-Charge Feedback
  • Trichel Pulses
  • Stepped Leader
  • Lightning Protection
In the full guide: 4 pages · 2 practice questions · 2 figures
04

Solid, Liquid and Surface Breakdown

Distinguish treeing, tracking and flashover by path and timescale

Location decides the failure label

Real solid insulation contains voids, droplets, particles and electrode irregularities that concentrate field and initiate local heating or discharge.

  • Electrical Treeing
  • Water Trees
  • Liquid Recovery
  • Surface Tracking
  • Dry-Band Arcing
  • Flashover
In the full guide: 3 pages · 2 practice questions · 1 figure
05

Insulation Design for HV Equipment

Connect field grading to cables, bushings and outdoor insulation

Design features answer known failure modes

Semiconductive cable screens smooth the field at stranded conductors, oil-paper processing removes voids, and XLPE reduces capacitance and dielectric loss.

  • Cable Screens
  • Oil-Paper Insulation
  • XLPE Cable
  • Bushing Foils
  • Creepage Paths
  • Insulator Grading
In the full guide: 3 pages · 2 practice questions · 1 figure
06

AC, DC and Impulse Test Sources

Select cascaded, resonant, multiplier and impulse arrangements

Waveform selects the source

High-voltage tests investigate service withstand, design performance or ultimate strength.

  • Cascaded Transformers
  • Series Resonance
  • Voltage Doubler
  • DC Multiplier
  • Impulse Shaping
  • Marx Generator
In the full guide: 3 pages · 2 practice questions · 1 figure
07

Partial Discharge Measurement

Calibrate apparent charge and interpret phase-resolved pulse evidence

Measure an equivalent terminal effect

Partial discharge is local activity that does not bridge the full insulation path.

  • Apparent Charge
  • Calibration Pulse
  • Coupling Network
  • Phase Pattern
  • UHF Detection
  • Acoustic Location
In the full guide: 4 pages · 2 practice questions · 1 figure
08

Transformer Condition Monitoring

Combine dissolved gases, furfural trends and sampling uncertainty

Interpret trend and mixture together

Dissolved gas analysis measures products created when electrical or thermal faults decompose transformer oil and paper.

  • Dissolved Gas Analysis
  • Fault Gas Pattern
  • Furfural
  • Cellulose Ageing
  • Sampling Error
  • Trend Diagnosis
In the full guide: 3 pages · 2 practice questions · 1 figure
09

Overhead Line Parameters and Surges

Convert conductor geometry into parameters, ratings and wave behaviour

Compress geometry without losing meaning

Geometric mean distance represents phase spacing, while geometric mean radius represents conductor or bundle construction.

  • Geometric Mean Distance
  • Self-GMR
  • Line Inductance
  • Line Capacitance
  • Surge Impedance
  • Wave Reflection
In the full guide: 4 pages · 2 practice questions · 1 figure
10

Underground Cable Design

Size insulation and test charging, loss and thermal constraints

Several limits compete for one design

Coaxial cable geometry produces high capacitance, low inductance and low surge impedance compared with an overhead line.

  • Radial Electric Field
  • Insulation Thickness
  • Cable Capacitance
  • Charging Current
  • Dielectric Loss
  • Thermal Grouping
In the full guide: 4 pages · 2 practice questions · 1 figure
11

Switchgear, Fuses and Breaker Ratings

Compare interruption media and calculate network fault duties

Interruption technology and rating are separate decisions

Air, oil, vacuum and SF6 breakers differ in arc control, voltage application, maintenance, safety and environmental burden.

  • Breaker Media
  • Fault MVA
  • Symmetrical Current
  • Peak Duty
  • Fuse Melting
  • Arc Interruption
In the full guide: 3 pages · 2 practice questions · 1 figure
12

Testing, Commissioning and Standards

Build a staged assurance chain from specification to energisation

Assurance begins before the equipment arrives

A fit-for-purpose specification defines service conditions, standards and acceptance evidence.

  • Fit-for-Purpose Specification
  • Factory Inspection
  • Routine Test
  • Site Test
  • Commissioning Hold Point
  • Standards Selection
In the full guide: 3 pages · 2 practice questions · 1 figure

Space charge and photoionisation can transform a large avalanche into a streamer, while pressure, electrode shape and surface condition decide whether a uniform-gap model remains useful.

The guide then contrasts corona, solid and liquid treeing, surface tracking and flashover so that a visible discharge is not automatically mislabelled as complete breakdown.

Testing and condition evidence

The middle chapters connect dielectric behaviour to practical sources and measurements.

Cascaded transformers, resonant testers, voltage multipliers and impulse generators create different waveforms for different insulation questions. Partial-discharge measurement uses calibrated apparent charge and phase patterns rather than claiming direct access to a hidden defect. Transformer monitoring combines dissolved gas mixtures with furfural evidence and sampling uncertainty.

The recurring method is to state what was measured, which mechanism it supports and what additional observation would distinguish a plausible alternative.

Lines, cables and interruption

The final technical block turns geometry into overhead-line inductance, capacitance and surge impedance, then contrasts that behaviour with coaxial underground cables.

Cable insulation thickness, charging current, dielectric loss and thermal grouping impose separate constraints. Switchgear chapters distinguish breaker technology from breaker rating, add grid, generator and motor fault contributions, and connect fuse melting to the following arc interval.

The closing chapter treats specification, factory inspection, site testing and commissioning as successive evidence gates rather than one final event.

Pass condition in the reviewed material

No separate attendance condition was identified in the reviewed assessment evidence. Pass eligibility requires a final-examination result of at least 35%.

Track that examination condition separately from the overall weighted total.

How to revise

Redraw each chapter figure, rebuild the original worked example with its numbers covered, and complete the changed-condition practice. Always state the physical regime before selecting an equation. Keep units, voltage basis, rms or peak convention and time regime visible.

Finish calculations with the engineering consequence, then test whether the conclusion survives a change in geometry, material, environment or operating condition.

Worked example · free

Check a cable charging-current limit

Q [6 marks]. AskSia-authored practice. A cable draws 4.3 A per kilometre of charging current and may use 90 A of its rating for charging. Calculate the length ceiling and state what the result does not prove. The mark allocation used here is not an official University scheme.
The concentric cable layers carry conductor potential outward through a smooth screen, bulk insulation, outer screen and grounded metallic sheath.The concentric cable layers carry conductor potential outward through a smooth screen, bulk insulation, outer screen and grounded metallic sheath.conductorinner screenXLPE insulationouter screenmetal sheath
The concentric cable layers carry conductor potential outward through a smooth screen, bulk insulation, outer screen and grounded metallic sheath.
  • 2Calculate length from allowed current divided by current per kilometre.
  • 2Report the result with units and a sensible precision.
  • 2Name another constraint that still needs checking.
The ceiling is 90 divided by 4.3, or about 20.9 km. This result addresses charging current only; dielectric loss, conductor temperature, voltage performance and installation constraints may impose a shorter route.
Sia tip — Write amperes divided by amperes per kilometre so the kilometre unit is visible before calculating.
Glossary

Key terms

Apparent Charge
Apparent Charge is the calibrated terminal charge that would reproduce the measured voltage change of a partial-discharge event.
Avalanche
Avalanche is the multiplying population of electrons created when ionising collisions outpace attachment in a gas.
Corona
Corona is a local partial breakdown sustained in a region of extreme electric field without bridging the full gap.
Creepage Distance
Creepage Distance is the surface path between conductors that an external discharge would have to follow.
Dielectric Loss
Dielectric Loss is the real power dissipated as polarisation and leakage processes cycle within insulation.
Dissolved Gas Analysis
Dissolved Gas Analysis interprets fault-related gases in transformer oil as evidence of discharge, heating or arcing.
Geometric Mean Distance
Geometric Mean Distance is the effective spacing used to represent a multi-conductor line geometry in parameter calculations.
Geometric Mean Radius
Geometric Mean Radius is the effective conductor or bundle radius used in inductance calculations.
Paschen Law
Paschen Law relates uniform-gap breakdown voltage to the pressure-distance product within its valid regime.
Streamer
Streamer is a conducting ionised channel formed when avalanche space charge and photoionisation create rapid secondary growth.
Tracking
Tracking is progressive carbonised surface damage produced by leakage current, dry-band arcing and repeated local discharge.
Treeing
Treeing is the growth of branching discharge channels through bulk solid or liquid insulation under concentrated stress.
FAQ

ELEC5205 FAQ

What makes gas insulation break down?

Free electrons gain energy from the electric field and create further electrons through ionising collisions. When net ionisation produces a sufficiently large avalanche, space charge and photoionisation can form a streamer and a conducting path. Pressure, gap length and electrode geometry decide whether the uniform-field model applies.

How is corona different from complete breakdown?

Corona is confined to a high-field region near an electrode or hardware feature and may remain stable through space-charge feedback. Complete breakdown bridges the insulation path and collapses its impedance. A visible or measured local discharge therefore does not automatically mean the whole gap has failed.

Why is partial discharge measured in apparent charge?

The true charge movement at a hidden defect cannot be measured directly at the equipment terminals. Calibration defines the terminal-injected charge that would create the same voltage response. This apparent charge is comparable and useful, but it must not be described as the microscopic defect charge.

What do dissolved gases reveal about a transformer?

The relative gas pattern supports hypotheses about low-energy discharge, oil or paper overheating and high-energy arcing. Trend, sample handling and operating history matter alongside the mixture. Gas evidence can suggest a fault class, but location and severity usually need complementary electrical, thermal or inspection evidence.

Which calculations matter most for lines and cables?

Overhead lines use conductor geometry to calculate GMD, GMR, inductance, capacitance and surge impedance. Underground cables add radial electric field, insulation thickness, charging current, dielectric loss and thermal constraints. Keep physical radius separate from self-GMR and use the voltage basis required by each formula.

What assessment and pass conditions apply?

The current structure uses laboratory reports, an individual project, a mid-semester test and a cumulative final examination. Their published weights total the unit mark. No separate attendance condition was identified in the reviewed assessment evidence. Pass eligibility requires a final-examination result of at least 35%, so aggregate marks and the examination condition must both be tracked.

What is known about the final examination?

The current schedule states that it is a 2.5-hour closed-book examination cumulative across lecture, laboratory, tutorial and assignment material. It does not specify a final-paper question count in the available files, so use current Canvas instructions for calculator, formula-sheet and detailed format information.

Chapter questions

Questions students ask in each ELEC5205 chapter

Why does avalanche size grow exponentially?
Each ionising electron can create additional electrons that undergo the same process, so the growth rate is proportional to the population already present. Integrating that proportional rate over distance produces an exponential rather than a linear relation. Chapter 01 · Gas Avalanche and Paschen Law
Why does compressed gas expose electrode defects?
High pressure can make the ideal bulk-gas prediction very strong, so local field enhancement and electron emission from microscopic hills or particles become comparatively important. Many starting electrons can reach streamer size with less avalanche gain. Chapter 02 · Nonuniform Fields, Pressure and Vacuum
Why does corona not always become a spark?
Space charge can lower the field near the initiating electrode after a burst, suppressing further streamer growth. The active high-field region may also be too short for streamers to cross the weak-field remainder of the gap. Chapter 03 · Corona and Stepped Breakdown
Where do electrical trees begin?
They can begin at gas voids, conductive particles, water droplets or microscopic electrode protuberances where the local field is enhanced. Heating, bond breaking and electrostatic forces extend the initial damage into branching hollow channels. Chapter 04 · Solid, Liquid and Surface Breakdown
Why do XLPE cables use semiconductive screens?
A stranded conductor has microscopic and macroscopic irregularities that would concentrate electric field in the polymer. A bonded carbon-loaded layer forms a smoother equipotential surface and reduces local stress that could initiate void discharge or treeing. Chapter 05 · Insulation Design for HV Equipment
Why is resonance useful for testing cables?
A long cable is strongly capacitive. Tuning a reactor against that capacitance produces a high test voltage while the supply covers mainly losses, so required source power is far below the reactive power circulating in the test circuit. Chapter 06 · AC, DC and Impulse Test Sources
Why is calibration required for partial-discharge measurement?
The measuring circuit, filter, amplifier and test-object capacitance transform the fast discharge pulse. A known injected charge establishes the relationship between displayed response and apparent charge for that exact measurement chain. Chapter 07 · Partial Discharge Measurement
Why are gas proportions useful?
Different electrical and thermal energies favour different decomposition products, so the relative mixture carries mechanism information. Absolute concentration still matters because a stable proportion with rapidly rising total gas can indicate increasing activity. Chapter 08 · Transformer Condition Monitoring
Why do inductance and capacitance use different radii?
Inductance includes internal magnetic flux and therefore uses the conductor self-GMR. Capacitance follows the external electric field and uses physical conductor radius because electric field is zero inside the conductor. Chapter 09 · Overhead Line Parameters and Surges
Why can charging current limit cable length?
Cable capacitance draws reactive current even when little real load is delivered. Because current grows with voltage, frequency, capacitance and length, a long AC cable can consume an unacceptable fraction of conductor rating. Chapter 10 · Underground Cable Design
Why do motors contribute to a fault?
Stored rotational energy keeps the machines turning immediately after bus voltage collapses. For the first cycles they behave as generators and feed current back into the fault through their subtransient reactance. Chapter 11 · Switchgear, Fuses and Breaker Ratings
Why are factory tests not enough?
Transport and installation can introduce damage or incorrect connections, while earthing, phasing, protection and interlocks only exist as an integrated site system. Site and commissioning evidence therefore answer questions that factory records cannot. Chapter 12 · Testing, Commissioning and Standards
Study strategy

How to study for the exam

Begin each revision session with one mechanism sketch: avalanche growth, corona zones, a cable radial field, a PD calibration loop or a travelling-wave junction. Rebuild the associated equation from definitions and check units before calculating. Then complete one original changed-condition problem and write the physical consequence in a final sentence.

Alternate early insulation chapters with later equipment chapters so that field concentration remains connected to the design feature that controls it. For the cumulative final, practise closed-book retrieval of formulas and symbol meanings, but do not treat the formula sheet as a decision engine.

Finish each week by recording one error in regime selection, one unit or voltage-basis error, and one interpretation that overclaimed the evidence. Rework those errors after a delay. Before the exam, confirm current operational instructions on Canvas and keep the published pass condition separate from the overall weighted mark.

Study ELEC5205 with AI

Your AI Electrical Engineering tutor for ELEC5205

Stuck on a hard ELEC5205 question? Sia is AskSia’s AI Electrical Engineering tutor — ask any ELEC5205 High Voltage Engineering question and get a clear, step-by-step explanation grounded in how the course is actually taught and assessed. Read this whole study guide free, then take your hardest questions to Sia.

A+Everything unlocked
Unlocks this Bible + all 202 of your University of Sydney subjects - and 1,000+ Bibles across every Australian university.
Sia - your ELEC5205 tutor, unlimited, worked the way the exam marks it
The full 50-page Bible + practice bank with worked solutions
Chrome extension - sync your LMS so Sia knows your deadlines
Bilingual EN / Chinese on every Bible and every Sia answer
$0.99 Trial
30-day money-back · cancel in one tap · how it works